D9412GV3/D7412GV3 Operation and Installation Guide EN Control Panels
D9412GV3/D7412GV3 | Operation and Installation Guide | Trademarks Trademarks CoBox is a registered trademark of Lantronix. Windows is a registered trademark of Microsoft Corporation in the United States or in other countries. Molex is a registered trademark of Molex Incorporated. Certifications and Approvals The D9412GV3/D7412GV3 Literature Pack includes the D9412GV3/D7412GV3 Approved Applications Compliance Guide (P/N: F01U143069).
D9412GV3/D7412GV3 | Operation and Installation Guide | Federal Communications Commission (FCC) Rules . If the D9412GV3 or D7412GV3 Control Panel causes harm to the telephone network, the telephone company attempts to notify you in advance. If advance notice is not practical, the telephone company notifies you as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
D9412GV3/D7412GV3 | Operation and Installation Guide | Federal Communications Commission (FCC) Rules Contents 1.0 2.0 2.1 2.2 3.0 3.1 3.1.1 3.1.2 3.2 3.3 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 3.3.6 3.3.7 3.3.8 3.3.9 3.3.10 3.3.11 3.3.12 3.3.13 3.3.14 3.3.15 3.3.16 3.3.17 4.0 4.1 4.2 4.3 4.4 4.5 4.5.1 4.5.2 4.5.3 4.5.4 4.5.5 4.6 4.6.1 4.6.2 4.6.3 4 Introduction ......................................................8 Lightning Strikes .............................................9 Effects .........................
D9412GV3/D7412GV3 | Operation and Installation Guide | Federal Communications Commission (FCC) Rules . 8.1 8.2 8.3 8.4 8.5 Terminals 11 to 22 Description......................33 Point Sensor Loops.........................................33 Point Parameters.............................................34 Point Response Time......................................35 Wiring Information for Installations Using the Rothenbuhler 5110/4001-42 High Security Bell .....................................................
D9412GV3/D7412GV3 | Operation and Installation Guide | Federal Communications Commission (FCC) Rules Two telco lines: ..............................................................75 Discharge Cycle.............................................................
D9412GV3/D7412GV3 | Operation and Installation Guide | Federal Communications Commission (FCC) Rules . Table 26: Table 27: Zonex 2 Point Address Chart .................74 Specifications............................................75 Bosch Security Systems, Inc.
D9412GV3/D7412GV3 | Operation and Installation Guide | 1.0 Introduction 1.0 Introduction This manual addresses the operation and installation of the D9412GV3 and D7412GV3 Control Panels. Throughout this guide, the words “control panel” refer to both control panels (D9412GV3 and D7412GV3). Table 2 on page 10 provides an overview of the differences in the control panels. To obtain any of the documents in Table 1, contact Bosch Security Systems, Inc.
D9412GV3/D7412GV3 | Operation and Installation Guide | 2.0 Lightning Strikes . 2.0 Lightning Strikes The control panels are designed to significantly reduce electromagnetic interference and malfunction generally caused by lightning. 2.1 Effects Any electronic system can be struck directly by lightning or be adversely affected by a lightning strike near the system.
D9412GV3/D7412GV3 | Operation and Installation Guide | 3.0 Overview 3.0 Overview 3.1 Configuration and Parts Figure 1: System Configuration D8129 OctoRelay provides alarm and auxiliary relay output. (Other functions available.) D9210B Modules can be used for access control. Each D8128D OctoPOPIT combines eight POPIT points in one module. DX4020 allows communciation over a Local or Wide Area Network (LAN/WAN). Control Panel D8125 or D8125MUX Interface used for point expansion.
D9412GV3/D7412GV3 | Operation and Installation Guide | 3.0 . 3.1.1 • Parts List The D9412GV3 andD7412GV3 Control Panels are shipped assembled from the factory with the following parts: Literature Pack • D9412GV3/D7412GV3 Program Record Sheet (P/N: F01U143072) • 9000/G/GV2 Series Technical Service Note: UL Smoke Detector Compatibility (P/N: 33284) • 7000/9000 Series Point Chart Label (P/N: 79-06660-000) Assembly • PC board • Faceplate shield • Mounting skirt • One #6 x 1/4-in. screw 3.1.
D9412GV3/D7412GV3 | Operation and Installation Guide | 3.0 Overview Table 3: Compatible Accessories (continued)1 Model D1255W D1256 D1257 D1260/D1260B2 D1640 D8004 D8125 D8125MUX D8128D D8129 D8130 D8132 D9127U/T D9131A D9210B ICP-SDI-9114 ZX776Z ZX794Z ZX865 ZX938Z ZX970 Title Text Keypad (white) Fire Keypad Fire Alarm Annunciator Keypads 16.
D9412GV3/D7412GV3 | Operation and Installation Guide | 3.0 Overview . 3.3 3.3.1 Features in the D9412GV3 and D7412GV3 SDI Molex Connector Use the SDI Molex Connector to connect easily an SDI device with the SDI bus, without needing to disconnect wires connected to the SDI terminals. Possible applications include: • Connecting a DX4010i to program the control panel with Remote Programming Software (RPS) at the premises • Connecting a keypad to test the control panel.
D9412GV3/D7412GV3 | Operation and Installation Guide | 3.0 Overview Table 4: Software Version Compatibility of D6500 MPU and Line Cards MPU D6510 D6511 Line Card D6540 D6541 Software Version 8.00 and higher 1.04 and higher 7.44 and higher 1.03 and higher The control panel connects to an RJ31X or RJ38X jack for telephone line seizure. Connecting to the RJ31X complies with FCC regulations for using the public telephone network.
D9412GV3/D7412GV3 | Operation and Installation Guide | 4.0 . 3.3.12 Event Log The system stores from 500 to 1000 events and event modifiers from all areas in its event log. Event modifiers add information about an event to the log. Some events are always followed by a modifier. For example, the system adds at least two items to the log each time an area is armed or disarmed, the Open (or Close) event and an event modifier showing the previous arming state.
D9412GV3/D7412GV3 | Operation and Installation Guide | 4.0 Installation 4.2 4.3 Enclosure Options Mount the control panel assembly in any of the Bosch Security Systems, Inc. enclosures listed: • D8103 Universal Enclosure (tan) • D8109 Fire Enclosure (red) • D8108A Attack Resistant Enclosure (tan) Refer to the D9412GV3/D7412GV3 Approved Applications Compliance Guide (P/N: F01U143069) to determine if the application requires a specific enclosure. Figure 2: Mounting Enclosure 1.
D9412GV3/D7412GV3 | Operation and Installation Guide | 4.0 Installation . Caution: Do not use telephone or electrical ground for the earth ground connection. Use 1.8 mm (14 AWG) to 1.5 mm (16 AWG) wire when making the connection. Figure 3: Enabling Ground Fault Detection F01U143074- 02 WARNING ! To pr even t risk of el ect ri c shock, di sconn ect AC po wer Devi ces pow ered byt he and t el ephon el n i es AUX p ower out put mu st bef or e ser vic ing . bes upervi sed.
D9412GV3/D7412GV3 | Operation and Installation Guide | 4.0 Installation If the reset pin is placed in the disable position when all areas are armed, there must be an entry in the Answer Armed program item. Refer to RPS Parameters in the D9412GV3/D7412GV3 Program Entry Guide (P/N: F01U143071). Locking the pin in the disable position applies power to the control panel and charges the battery while the detection devices and keypads are installed.
D9412GV3/D7412GV3 | Operation and Installation Guide | 4.0 . 4.6.5 Powering Up Test after initially programming the control panel. Reconnect the battery, then plug in the transformer. The buzzer sounds for two sec when the control panel is powered up. Leave the reset pin in the locked position.
D9412GV3/D7412GV3 | Operation and Installation Guide | 4.0 Installation 1. Choose a keypad to conduct the test. Ensure that the display shows the idle disarmed text. 5. To see the points that remain untested during the Service Walk Test: 2. Press the [MENU] key to enter the Function List. Press [NEXT] repeatedly until the SERVICE WALK ? prompt appears. a. Press [ESC] when point text appears. The display shows ## PTS TO TEST. 3.
D9412GV3/D7412GV3 | Operation and Installation Guide | 4.0 Installation .
D9412GV3/D7412GV3 | Operation and Installation Guide | 4.
D9412GV3/D7412GV3 | Operation and Installation Guide | 5.0 Power Supply . 5.0 Power Supply 5.1 Primary Power Terminals 1 and 2 5.1.1 Primary (AC) Power Circuit The primary source is a 16.5 VAC, 40 VA, internallyfused transformer (Bosch Security Systems, Inc. Model D1640). The control panel draws 200 mA when idle and 300 mA when in an alarm state. The total available auxiliary current is 1.4 A. Transient suppressors and spark gaps protect the circuit from power surges.
D9412GV3/D7412GV3 | Operation and Installation Guide | 5.0 Power Supply 2. Locate the red and black leads supplied in the literature pack. 3. Connect the black battery lead to Terminal 4, and then to the negative (-) side of the battery. 4. Connect the red battery lead to Terminal 5, and then to the positive (+) side of the battery. Warning: High current arcs are possible. The positive (red) battery lead and Terminal 5 can create high current arcs if shorted to other terminals or the enclosure.
D9412GV3/D7412GV3 | Operation and Installation Guide | 5.0 Power Supply . 5.2.3 Replacing the Battery Figure 8: Charging and Battery LEDs Replace batteries every 3 to 5 years under normal use. Record the date of installation directly on the battery. L EDs Off When No rmal Caution: Exceeding the maximum output ratings or installing the transformer in an outlet that is routinely switched off causes heavy discharges. Routine heavy discharges can lead to premature battery failure.
D9412GV3/D7412GV3 | Operation and Installation Guide | 5.0 Power Supply Overcharge Load Shed With AC Present: If more than 1.4 A of auxiliary current draw from the control panel occurs, the battery supplies the current and begins to discharge. If this situation is not corrected, the battery continues to discharge and at 11.8 VDC to 12.0 VDC, the keypads display Serv Low Batt. When the battery voltage drops below 10.0 VDC, the control panel shuts down.
D9412GV3/D7412GV3 | Operation and Installation Guide | 6.0 Power Outputs . 6.0 Power Outputs 6.1 Circuit Protection Three self-resetting circuit breakers protect the control panel from short circuits on the continuous and programmable power outputs. If the control panel is programmed for power supervision and a short circuit occurs on one of the power outputs, the control panel sends BATTERY LOW and BATTERY MISSING when using Bosch Security Systems, Inc. Modem IIIa2 communicator format.
D9412GV3/D7412GV3 | Operation and Installation Guide | 6.0 Power Outputs Voltage Output at Terminals 6, 7, and 8 If Terminals 6, 7, and 8 do not provide the expected output, check: • Programming for Relays A, B, and C in the relays section of the program. • Bell Parameters section of the program to confirm that the Alarm and Fire Bell responses are programmed for the expected duration and pattern. • Point Assignments section to confirm that each point is programmed for the expected local response. 6.4.
D9412GV3/D7412GV3 | Operation and Installation Guide | 7.0 Telephone Connections . 7.0 Telephone Connections 7.1 Figure 9: RJ31X Wiring Registration RING (red) R1 R The Bosch Security Systems, Inc. D9412GV3 and D7412GV3 Control Panels are registered with the Federal Communication Commission (FCC) under Part 68, for connection to the public telephone system using an RJ31X or RJ38X jack installed by the local telephone company.
D9412GV3/D7412GV3 | Operation and Installation Guide | 7.
D9412GV3/D7412GV3 | Operation and Installation Guide | 7.0 Telephone Connections . 7.5 Phone LED (Red) The red Phone LED illuminates when the control panel seizes the telephone line and remains illuminated until the control panel returns the telephone line. Refer to Figure 10 on page 30 for the location of the red LED. 7.6 Operation Monitor LED (Green) The green Operation Monitor LED indicates the operation of the central processing unit (CPU). When the CPU is operating normally, the LED flashes 0.
D9412GV3/D7412GV3 | Operation and Installation Guide | 7.0 Telephone Connections 7.11 D928 Dual Phone Line Switcher Figure 11: D928 Dual Phone Line Switcher 7.11.1 Description The optional D928 Dual Phone Line Switcher allows the control panel to send reports over two separate telephone lines. If a telephone line is not within the operating range, the control panel attempts to use the other telephone line to send the message.
D9412GV3/D7412GV3 | Operation and Installation Guide | 8.0 . 7.11.3 Installing the D928 Phone Line Fail LEDs Mounting Mount the D928 on the lower right side of the enclosure using the screws provided with the switcher. Wiring The D928 has two flying leads. The green lead monitors AC power. The black lead is the ground reference for the AC Power LED. 1. Connect the green lead from the D928 to Terminal 1. 2. Connect the black lead from the D928 to Terminal 9. Telephone Connections 1.
D9412GV3/D7412GV3 | Operation and Installation Guide | 8.0 On-Board Points The number of normally-open and normally-closed detection devices each sensor loop can supervise is limited only by the resistance on the loop. The total resistance for the wire length and contacts, minus the end-of-line (EOL) resistor, must not exceed 100 Ω. 8.3 Point Parameters The condition of on-board Points 1 to 8 is determined by measuring the voltage across the point input terminal and one of the common terminals.
D9412GV3/D7412GV3 | Operation and Installation Guide | 8.0 On-Board Points . 8.4 Point Response Time The control panel scans on-board and off-board point sensor loops every 300 ms. The Debounce program item in the Point Assignment section of the software determines point response time by setting the number of times the control panel scans a point before generating an alarm. The debounce count can range from 2 to 15; therefore, point response time ranges from 600 ms to 4.5 sec.
D9412GV3/D7412GV3 | Operation and Installation Guide | 8.0 On-Board Points Figure 13: Rothenbuhler 5110/4001-42 High Security Bell Wiring Configuration 2 1 3 1 6 0.64 mm (1/4 in.
D9412GV3/D7412GV3 | Operation and Installation Guide | 8.0 On-Board Points . Figure 14: Wiring the Rothenbuhler 5110/4001-42 High Security Bell to the D9412GV3 or D7412GV3 Control Panel 4 1 9 1 7 9 2 13 5 6 6 2 3 3 RE D ORG WHT BL K 7 4 12 8 9 1 2 3 3 6 11 9 N/O 1 10 COMM 1 N/C 1 X1 X1+ 1234567• 5110 Logic Board 4001-42 External Line Balancing Module D9412GV3 or D7412GV3 Control Panel Alarm output Alternate alarm Common +12.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points 9.0 Off-Board Points 9.1 Point (Zonex) Bus: D9412GV3 Terminals and D7412GV3 Terminals 9.1.1 POPIT Modules The D9412GV3 can use point of protection input transponder (POPIT) modules to provide a maximum of 238 off-board points, bringing the total number of points the D9412GV3 can monitor to 246. The D7412GV3 provides up to 67 off-board points, bringing the total number of points the D7412GV3 monitors to 75.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points .
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points . Figure 16: Connecting the D8125 POPEX to the D7412GV3 Control Panel 2 Reset Pin Dis able all exc ept Bat ter y RED - Lo w Batter y -Cha rg ing a nd Pr ogr am min g 4 D912 7U/T 3 PE RIPH ER AL DE VICE CO NN EC TION S CLA SS 2 TRA NSFO RM E R 1 6.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points 9.3 Installing the D8125 POPEX Module For information on the Multiplex Bus Interface, refer to the D8125MUX Multiplex Bus Interface Operation and Installation Guide (P/N: F01U034973). Save the POPIT Label Sheets: The D8125 is packaged with two sets of POPIT label sheets. One set is marked “Bank 1” for use with the D7412GV3 and D7212GV3. The other set is marked “Bank 2” for use with the D9412GV3 and D9112.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 . 9.3.4 Wiring Data Expansion Loops to POPEX Modules For the D9412GV3, Points 73 to 127 and 193 to 247 must use the D9127 POPITs. Points 9 to 72 and 129 to 192 can use either D8127 or D9127 POPITs. Each POPEX Module has two positive (+) and two negative (-) data expansion loop terminals. Up to 119 POPITs can be connected to one D8125 on the D9412GV3; up to 67 POPITs for the D7412GV3 (Figure 15 on page 40 and Figure 16 on page 41).
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points Figure 17: Program Record Sheet EN | 25 D9412GV2/D7412GV2 | Program Record Sheet | RADXPNTS Handler bold Default values are shown in ( ) or in bold Point Assignments (001 through 040) POPIT Switch Setting 0 1 2 3 4 5 6 9.3.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 . 9.4.2 Listings The D8128D OctoPOPIT Module is UL Listed for Local or Police Connected Burglary Alarm, Central Station Burglary Alarm, Household Burglary Alarm applications, and commercial fire applications (UL 864 and NFPA 72).
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points 9.4.3 Installation Table 15: For the most effective installation, use the following four-step process: D8128D OctoPOPIT Switch Settings for D9412GV3 and D7412GV3 1. Set the OctoPOPIT switches. Refer to Section 9.4.4 Setting the OctoPOPIT Switches. ZONEX 1 2. Physically mount the OctoPOPIT in the enclosure. Refer to Section 9.4.5 Mounting OctoPOPITs, page 47.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 . Use the point DIP switches to disable conflicting points, such as when a D9210B Access Control Module must be assigned to a point that falls within the range of the D8128D OctoPOPIT. In this example, a D9210B is assigned to Point 20. On the same system, a D8128D OctoPOPIT is assigned to Points 17 through 24.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points Figure 19: Connecting D8128D OctoPOPITs to the D9412GV3 5 1 Reset Pi n Disabl e all except Battery Charging and Programmi ng R ED DATA BUS A G REEN DATA BUS B B LACK CO MM ON ZO NEX OUT 1 6 ZO NEX OUT 2 26 ZO NEX IN 2 25 ZO NEX POWER + 24 ZO NEX COM MO N 23 Clos ed = 1 k Ω EOL N or m al Ope r ati on Op en = AB-1 2 UL Bel l Bo x 2 20 kΩ 22 6 Z ONEX I N 1 Poi nt 8, S3 Option 21 4 2 POWER + YEL LO W N .F.P.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points . Figure 20: Connecting D8128D OctoPOPITs to the D7412GV3 1 2 1 2 Reset Pi n Disabl e all except Battery Charging and Programmi ng PERIPHERAL DEVICE CON NECTIO NS R ED POWER + YEL LO W DATA BUS A G REEN DATA BUS B B LACK 1 CO MM ON N .F.P. A. St yle 4.
l o o p w ti h a 1 k • D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points ® Using Molex Connectors Each D8128D Module is supplied with a 30 cm (12 in.) female-to-female Molex cable assembly. P1 and P2 are Molex connectors that parallel the COM, IN, OUT, and +12.0 VDC terminals on the terminal strip.
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0 Off-Board Points . Figure 22: D8128D OctoPOPIT Sensor Loops 1 COM IN OUT+12V P1 COM P2 P3 COM P4 P5 COM P6 2 P7 COM P8 3 4 5 12345- 9.5 D8128D OctoPOPIT To control panel To additional OctoPOPIT sensor loops OctoPOPIT sensor loops 1 kΩ EOL resistor (P/N: P105BL, package of eight) Testing Off-Board Points Use the Service Walk Test to test off-board points. Test to ensure that all off-board points operate properly.
D9412GV3/D7412GV3 | Operation and Installation Guide | 10.0 Off-Board Relays 10.0 Off-Board Relays 10.1 D8129 OctoRelay Use the D8129 OctoRelay to add relay outputs to the system in groups of eight. On the D9412GV3, up to 128 OctoRelay outputs (relay numbers 1 to 128) can be added to the system using 16 OctoRelays. D7412GV3 allows up to 64 relay outputs. Review Section 6.
D9412GV3/D7412GV3 | Operation and Installation Guide | 10.0 Off-Board Relays . Figure 24: D8129 Connections to the D7412GV3 R es e t Pin Dis able a ll ex c e pt Ba tte ry Cha rging a nd Progr am m ing PERIPHERA L DEVICECO NNECTIO NS RED PO WER + YELLO W DATA BUS A GREEN DATA BUS B BLACK COMM ON N.F .P.A. Sty le 4 .
D9412GV3/D7412GV3 | Operation and Installation Guide | 10.0 Off-Board Relays To install OctoRelays in the enclosure with the control panel: 1. Align the module with one of the mounting locations in the enclosure (refer to Figure 2 on page 10). 2. Using the screws provided with the module, secure the module in the enclosure. Use the D137 Mounting Bracket or D9002 Mounting Skirt to install OctoRelays in enclosures with no available module mounting locations. 10.1.
D9412GV3/D7412GV3 | Operation and Installation Guide | 10.0 Off-Board Relays . 10.2.2 Installation 10.2.3 Wiring Connections Install the D811 in the enclosure with the control panel (Figure 25) or in an adjacent enclosure no more than 1.5 m (5 ft.) from the control panel. Use 1.5 mm (16 AWG) to 0.8 mm (22 AWG) wire. Power down the control panel to connect D811 Modules as shown in Figure 25 on this page and Figure 26 on page 56. The D811 for Relay 53 connects to Zonex 1.
D9412GV3/D7412GV3 | Operation and Installation Guide | 10.0 Off-Board Relays Figure 26: D811 Module Wiring to the D7412GV3 Re s et P n i D is a ble all e x c ept B att er y Cha rging a nd P rogra m m in g PERIPHERAL DEVICE CONNECTIONS RED POWER + YELLOW DATABUS A GREEN DATABUS B BLACK N.F.P.A. Sty le 4.
D9412GV3/D7412GV3 | Operation and Installation Guide | 11.0 Arming Devices . • 11.0 Arming Devices 11.1 Description D720/D720B - LED display keypad appropriate for use as a single area keypad with up to eight points. D1255 and D720 are available in white (D1255W and D720W) or red (D1255R and D720R). Keypads, maintained or momentary contact keyswitches, or a combination of the two are used to arm and disarm areas. The control panel can contain up to eight areas. Refer to 3.3.
D9412GV3/D7412GV3 | Operation and Installation Guide | 11.0 Arming Devices 11.2.2 Installation Extra Power for More Keypads Refer to the keypad installation manuals for installation and mounting instructions. Keypads connect to the control panel in parallel (Table 21). The D1255 and D1255B Keypads draw 104 mA when idle. They draw 206 mA with the keys lit and the sounder activated. Review Section 6.0 Power Outputs on page 27 to determine the total power output requirements for the system.
D9412GV3/D7412GV3 | Operation and Installation Guide | 11.0 Arming Devices . Figure 27: Power at Keypads 5 2 1 3 2 4 3 4 1 - To control panel 2 - +12.0 VDC 3 - Data 11.3 D279A Independent Zone Control Any on-board or OctoPOPIT point can be programmed so that the D279A Independent Zone Control operates as independent point control (arming and disarming the point). Refer to Point Assignments in the D9412GV3/D7412GV3 Program Entry Guide (P/N: F01U143071) for programming information.
D9412GV3/D7412GV3 | Operation and Installation Guide | 11.0 Arming Devices Silencing the Bell To silence the bell (stop Alarm Bell output) if the system is armed, position the keyswitch to disarm the area. If the area is disarmed, turn the keyswitch once to start the arming process. Turning the keyswitch a second time stops the arming process and silences the bell. 60 Bosch Security Systems, Inc.
D9412GV3/D7412GV3 | Operation and Installation Guide | 11.0 Arming Devices . Figure 28: Keyswitch Wiring 2 1 6 3 7 3 5 4 1234∗ Maintained keyswitch Momentary keyswitch Common Point input 5 4 5 - 1 kΩ or 33 kΩ resistor ∗ 6- Open on a circuit arms the area 7 - Short on a circuit toggles the arming state Use 1 kΩ EOL resistors if using one of the zones on the control panel or an OctoPOPIT. Use a 33 kΩ resistor if using a POPIT. Bosch Security Systems, Inc.
D9412GV3/D7412GV3 | Operation and Installation Guide | 12.0 SDI Devices 12.3 12.0 SDI Devices 12.1 Description D9412GV3 and D7412GV3 Control Panels can support a number of accessory devices from the SDI Bus using Terminals 29 through 32. Some devices include the D1255 and D1255B Keypads (refer to Section 11.
D9412GV3/D7412GV3 | Operation and Installation Guide | 12.0 SDI Devices . 12.4 D9210B Wiegand Control Interface Module The Bosch Security Systems, Inc. D9210B Wiegand Control Interface Module is a four-wire powered device providing connections for an access door point and door strike. The D9412GV3 can supervise eight Wiegand Control Modules, the D7412GV3 can supervise two. Each D9210B supports one door to control access. Programming allows each access door to be configured independently. 12.4.
D9412GV3/D7412GV3 | Operation and Installation Guide | 13.0 Programmer and Accessory Connections If supervised and the module does not respond to control panel supervision polls, SERVC SDI 88 appears at the keypad. The report to the receiver includes the address of the troubled module indicating which module needs service. Accessory Connector Use the accessory connector to connect the control panel to the D928 Dual Phone Line Switcher.
D9412GV3/D7412GV3 | Operation and Installation Guide | 14.0 Faceplates . 14.0 Faceplates 14.1 D9412GV3 Faceplate Figure 32: D9412GV3 Faceplate F01U14 3074- 02 LED s O ff Wh en No r m al In co r re ct w iri ng w ill d am ag e th is eq u ip m en t. Suit ab le fo r d r y in d o or us e o n ly. T o pr e ve nt r isk o f e le ct ric s ho c k, d is co nn ec t AC po w er a n d tel ep h on e lin es b e fo re s er vi cin g .
D9412GV3/D7412GV3 | Operation and Installation Guide | 14.0 Faceplates 14.2 D7412GV3 Faceplate Figure 33: D7412GV3 Faceplate F01U14 3074- 02 In co r re ct w iri ng w ill d am ag e th is eq u ip m en t. LED s O ff Wh en No r m al 1 1 0.
D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A . Appendix A: System Wiring Diagrams, Issue A A.1 D9412GV3 Control Panel Figure 34: D9412GV3, Power Supply Side D113 - BAT 2- CHGR- BAT 2+ VAUX+ BAT 1- SUPV BAT 1+ CHGR+ + - + 3 4 2 - - + + 6 2 2 C LA SS 2 T RA NS FO RM E R 1 6.
D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A Figure 35: D9412GV3, Input Points and Peripheral Devices CLASS 2 TRANSFORMER 16 .5 VAC4 0 VA 60 Hz Mode l D16 40 I te rna lly Fus ed - Do not s hort n Requir es Uns witched Outle t Do nots hare w ti h oth e r equip me nt RED D9412GV3 + A UX PO WER BATTERY N EGATIVE O NLY CAU TIO N: Avoid da ma ge to Pane .l Do notc onnec t 24 Vto term n i as l. Ma x imum c harging c urre nt 1.
D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A . Figure 36: D9412GV3, SDI Devices CLASS 2 TRANSFORMER 16 .5 VAC4 0 VA 60 Hz Mode l D16 40 In terna lly Fused - Do not s hort Requir es Unswitched Outle t Do notshare w ti h oth er equip ment RED D9412GV3 + A UX PO WER BATTERY N EGATIVE O NLY CAU TIO N: Avoid da ma ge to Pane l. Do notconnec t 24 Vto termin a ls . Max imum charging current 1.
D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A A.2 D7412GV3 Control Panel Figure 37: D7412GV3, Power Supply Side BAT 2- CHGR- B AT 2+ VAUX+ B AT 1- S UPV BAT 1+ CHGR+ 6 BATTER Y NEG ATIVE O NLY CAU TION: Av oid dam age to Pa ne l. Do notc onne ct 2 4 V to te rm in a ls. M a x im um c ha rging c ur re nt 1.
D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A . Figure 38: D7412GV3, Input Points and Peripheral Devices CLASS 2 TRA NSFOR ME R 16 .5 VAC 4 0 VA 60 Hz Mode l D1 6 40 Int er na lly Fuse d - Do not s hort Re quir e s Uns w itche d Out e lt Do not sha re w ti h othe r e quipm ent D7412GV3 + AUX POWER BATTERY NEGATIVE ONLY CAUT ION: Av oid da ma ge to Pa nel. Do not conne c t 24 V to te rm ina ls. Maxim um char ging cur rent 1.
D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A Figure 39: D7412GV3, SDI Devices D7412GV3 PO WE R + PO WER + R ED YE LLO W DDAATA B US AA G RE EN D A TA B US B D ATA B US B CCOOM M ONN B LAC K N .F. P. A. St yl e 3.
D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix B: Point Address Charts . Appendix B: Point Address Charts B.1 Zonex 1, Points 9 to 127 (D9412GV3); Zonex 1, Points 9 to 75 (D7412GV3) Place the labels on the base of the POPIT. Do not attach labels to the POPIT cover. A bullet (•) in the switch column indicates that the switch is set to ON. D8127 or D9127 POPITs can be used for Points 9 to 72; however, only D9127 POPITs can be used for Points 73 to 127.
D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix B: Point Address Charts B.2 Zonex 2, Points 129 to 247 (D9412GV3 Only) Place the labels on the base of the POPIT. Do not attach labels to the POPIT cover. A number in the switch column indicates that the switch is set to ON.
D9412GV3/D7412GV3 | Operation and Installation Guide | Specifications . Specifications Table 27: Specifications Voltage Input (Power Supply) Current Requirements Power Outputs* Primary: Secondary: All external connections are power-limited except battery terminals. Continuous Power Outputs Alarm Power Output Fire and Fire/Burglary Systems Telephone Connections Battery Discharge/ Recharge Schedule 16.5 VAC 40 VA class 2 plug-in transformer (D1640) Sealed lead-acid rechargeable battery (12.
Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 (800) 289-0096 www.boschsecurity.com © 2010 Bosch Security Systems, Inc.