Data Sheet

Intrusion Alarm Systems | D7212GV3 Control Panel
D7212GV3 Control Panel
www.boschsecurity.com
u Fully integrated intrusion and fire functions allow
users to interface with one system instead of two
u Conettix IP‑based communication options provide
high‑speed, secure alarm transport and control
through connection of up to two wired (DX4020)
and/or wireless (ITS‑DX4020‑G) network interfaces
u Four programmable areas with perimeter and
interior partitioning
u 40 points with flexible configuration options to meet
application specific requirements
u Commercial Wireless allows up to 32 RF points
The D7212GV3 Control Panel delivers a powerful new
solution for intrusion (commercial and residential) and
residential fire alarm system applications. Monitor
alarm points for intruder or fire alarms while operating
user command centers and other outputs. The
D7212GV3 Control Panel includes a communicator
that sends event reports to selected public switched
telephone network (PSTN), IP network, or general
packet radio service (GPRS) destinations through four
programmable route groups. Program all system
functions locally or remotely (attended or unattended)
through Remote Programming Software (RPS);
program critical parameters on site through a keypad.
The D7212GV3 Control Panel provides up to 40
individually identified points. Each point
accommodates normally-open and normally-closed
devices with end-of-line (EOL) resistor supervision.
Each point is programmable for fire, fire supervisory,
or intrusion applications.
Functions
Programmable Outputs
2 A alarm power at 12 VDC
1.4 A auxiliary power at 12 VDC
Four alarm output patterns
Automatic bell test
Three on-board outputs, 24 off-board programmable
outputs
System Response
High performance micro‑controller provides industry
leading system response
31 custom point indexes, including fire supervisory
Selectable point response time
Cross point capability
Fire alarm verification
Watch mode
Scheduled events (skeds) arm, disarm, bypass and
unbypass points, control relays, and control authority
levels
Area Configurations
Area programming offers a wide selection of different
system configurations. Each area is assigned an
account number to define annunciation, control, and
reporting functions. Multiple areas can be linked to a
shared area which is automatically controlled (hallway
or lobby). Area arming can be conditional on other
areas (master or associate). Any area can be
configured for perimeter and interior arming, not
requiring a separate are for this function.