Installation Guide

D7212GV3 | Operation and Installation Guide | 3.0 Overview
8 Bosch Security Systems, Inc. | 10/10 | F01U143079-03
3.0 Overview
3.1 Configuration and Parts
Figure 1: System Configuration
Use keypads or keyswitches to arm the control
panel by area. Each control panel can have up to four
areas. Each area can have its own account number or
areas can be grouped together with a common account
number. Points of protection are assigned to areas.
Control
Panel
On-Board Points
1 to 8
D9131A Module connects
to a parallel printer to print
the event log.
D8129 OctoRelay provides alarm
and auxilliary relay output.
(Other functions available.)
D8125, ISW-D8125CW-V2,
or D8125MUX Interface
used for point expansion.
Each D8128D OctoPOPIT combines
eight POPIT points in one module.
D8132 Modules (two 12 VDC) provide
additional power for keypads and other
powered devices.
DX4020 or ITS-DX4020-G allows
communication over a Local or
Wide Area network (LAN/WAN).
Table 2: GV3 Series Control Panel Differences
Features D9412GV3 D7412GV3 D7212GV3
Access Control
Yes - 8 doors Yes - 2 doors No
Arm/Disarm Passcodes
249 99 99
Cards/Tokens
996 396 N/A
Passcode-Protected Custom
Functions
16 4 4
Number of Printers 3 1 1
Number of Points 246 75 40
Number of Relays 128 64 24
Number of Areas 32 8 4
Number of D1255 Keypads 16 16 8
Number of D1260 Keypads 8 8 8