4.6.2 Installing and Wiring Detection Devices
Install and wire detection devices and keypads at
their locations throughout the premises.
Do not
connect the control panel yet.
Section 8.0 On-Board Points on page 37
contains instructions for wiring the on-board
points to detection devices. Section 11.0 Arming
Devices on page 62 contains instructions for
wiring the keypads.
Instructions for wiring the off-board point POPIT
sensor loops are found in the instructions
packaged with the POPIT modules.
4.6.3 Installing Modules and Relays
1. Power down the unit by unplugging the
transformer and disconnecting the battery.
Always power down the unit when
installing modules or relays, or when
making wiring connections to the
control panel.
2. Install and wire any modules required for the
installation as described in the module’s
installation instructions.
Instructions for the D8125 POPEX Module,
D8128D OctoPOPIT Module, D8129
OctoRelay Module, D811 Arm Status Relay
Module, and D928 Dual Phone Line Switcher
appear in this guide.
Refer to Section 9.0 Off-Board Points on page
40 for D8125 and D8128D instructions.
Refer to Off-Board Relays on page 54 for
D8129 and D811 instructions. Refer to
Section 7.11 D928 Dual Phone Line Switcher
on page 34 for D928 instructions.
3. If using the power outputs at Terminals 7 or
8, refer to Section 6.4 Programmable Power
Output Terminals 6, 7, and 8 on page 30 for
instructions.
4.6.4 Connecting the On-board Points and
Keypads
Connect the on-board points and keypad wiring
to the system. Refer to Section 8.0 On-Board
Points on page 37 and Section 11.0 Arming
Devices on page 62 for instructions.
4.6.5 Powering Up
Reconnect the battery, then plug in the
transformer. The buzzer sounds for two sec when
the control panel is powered up. Leave the reset
pin in the locked position.
Yellow Charging Status LED Remains Lit: If the
yellow charging status LED remains lit after five
minutes of powering up the control panel, either
the battery is deeply discharged or too many
powered devices were connected to the control
panel. Combined continuous current draw for
Terminals 3, 8, 24, and 32, and the accessory
connector cannot exceed 1.4 A. Refer to Section
6.0 Power Outputs on page 30 for help.
4.7 Updating Control Panel Firmware
When a firmware update is available, installation
of the update is performed using either a ROM
Update Key or using RPS. Refer to the
D9412GV4/D7412GV4/D7212GV4 ROM Update
Key Instructions on the underside of the control
panel faceplate, or refer to RPS Online Help.
4.8 Programming the Control Panel
If the control panel is not already programmed,
review the D9412GV4/D7412GV4/D7212GV4
Program Entry Guide (P/N: F01U218312). Ensure
that all accessory modules for desired features
are available for installation.
Use RPS to load a custom program into the
control panel as needed.
4.9 Installing the Point Chart Label
The point chart label is required for
fire systems with verifications points.
A point chart label is included in the literature
pack. Install the point chart label for fire or
combined fire-and-burglary systems that use
verification points.
Use the D9412GV4/D7412GV4/D7212GV4
Program Record Sheet (P/N: F01U214958) to
gather the necessary information for completing
the point chart. Fill out the label and install it on
the inside of the enclosure door (refer to Figure 2
on page 16).
Avoid smearing the entries on the
chart. Use the peel-off backing to
press the label in place.
4.10 Testing the System
After installing and programming the control
panel, test the system completely. Test the
control panel and all devices for proper
operation.