Installation Guide

D9412GV4/D7412GV4/D7212GV4 | Installation and Operation Guide | 12.0 SDI Devices
Bosch Security Systems, Inc. | 3/12 | F01U266054-01 67
The control panel sends an SDI Failure Report to
the receiver if communication with the printer
interface fails. If an SDI failure occurs, SERVC
PRINTER appears at the keypad. The report to
the receiver includes the address of the troubled
D9131A to indicate which printer needs service.
If an SDI device is supervised and Terminal 31
(SDI A+) becomes disconnected, the device can
continue to operate normally, depending upon
environmental conditions.
12.4 D9210C Access Control Interface
Module (D9412GV4 and
D7412GV4)
The Bosch Security Systems, Inc. D9210C Access
Control Interface Module is a four-wire powered
device providing connections for an access door
point and door strike. The D9412GV4 can
supervise eight Wiegand Control Modules, the
D7412GV4 can supervise two. Each D9210C
supports one door to control access.
Programming allows each access door to be
configured independently.
12.4.1 Access
Using Wiegand style cards or tokens, the D9210C
can allow access for up to 999 cards or tokens on
the D9412GV4, and up to 399 on the D7412GV4.
User access authority can be configured to
restrict access to certain doors or to certain
periods of time. The reading of access cards, in
addition to granting access, can control whether
the system disarms.
12.4.2 Switch Settings
Rotary switches on the D9210C assign a unique
address to each module. Table 23 shows the
correct switch setting for each D9210C address.
Table 23: Address Switch Settings for
Access Control Module
Door
Controller
Combined Rotary
Switch Settings
Fail Safe
Response
Default 0 -
1 81
Unlock
2* 82
Unlock
3 83
Unlock
4 84
Unlock
5 85
Unlock
6 86
Unlock
7 87
Unlock
8 88
Unlock
1 91
Lock
2* 92
Lock
3 93
Lock
4 94
Lock
5 95
Lock
6 96
Lock
7 97
Lock
8 98
Lock
*D7412GV4 supports doors 1 & 2
12.5 SDI Addresses 88 and 92
SDI Addresses 88 and 92 are available with the
GV4 Series Control Panels and are used for
several different applications. Only one device
can be assigned to SDI Address 88 at a time.
Likewise, only one device can be assigned to SDI
Address 92 at a time. When the Reset Pin
(labeled S1) is closed, all SDI communication
module addresses are automatically enabled for
RPS communication without restriction. Refer to
Figure 4: Reset Pin on page 18 to locate the
reset pin.
12.5.1 Local RPS Programming
Use the DX4010i or the DX4010V2 serial
communication module at SDI Address 88 or SDI
Address 92 to locally connect with RPS in
Enhanced Direct mode. This connection method
also allows diagnostic and history retrieval.