Test after initially programming the
control panel.
To meet UL 864 requirements,
perform a full system test after any
subsequent programming session.
Refer to Section 4.11 Service Walk Test on page
20 for complete Service Walk Test instructions.
Clear after Test: To clear the event memory and
report buffer, momentarily close the reset pin.
Events stored in the control panel’s event log are
not cleared.
4.11 Service Walk Test
The Service Walk Test differs from the standard
Walk Test. In the standard Walk Test, point
expansion modules whose switches are set for a
point number not programmed in the control
panel
do not appear in the test. In the Service
Walk Test, POPITs whose switches are set for a
point number that is not programmed in the
control panel do appear in the test.
The Service Walk Test allows a user to walk test
all 246 points from a control-panel-wide keypad,
regardless of the point index type.
A Service Walk Test can also be initiated by
account-wide or area-wide keypads but test only
those points that are within the scope of the
keypad that initiated the function. The Service
Walk Test does not test points in armed areas.
Only Walk Test Start and Walk Test
End are reported to the central
station.
The D9131A can be configured for
local printing. Refer to the
D9412GV4/D7412GV4/D7212GV4
Program Entry Guide (P/N:
F01U218312).
During a Service Walk Test, the
summary alarm and summary fire
remain off, because there are no Fire
or Burg alarm conditions to
summarize. The P# Relay Response
Type feature operates as
programmed.
Service Walk Test Procedure
Refer to Figure 5 on page 23 for Service Walk
Test options. Refer to the Walk Test procedures
in the D9412GV4/D7412GV4/D7212GV4 Owner’s
Manual Supplement (P/N: F01U245224) when
using a D1260 or D1260B Keypad.
1. Choose a keypad to conduct the test. Ensure
that the display shows the idle disarmed text.
2. Press the [MENU] key to enter the Function
List. Press [NEXT] repeatedly until the
SERVICE
WALK ? prompt appears.
3. Press [ENT], or press [9][9] followed by
[ENT] to reach the Service Menu to access
the Service Walk Test.
The D7412GV4 and D7212GV4 do not
include the Service Walk Test in the
Service Menu. To enable the Service
Walk Test function for any GV4 Series
Control Panel, add its function code
to the Function List of a keypad.
4. The display shows ### PTS TO TEST .Test the
first detection device.
5. When a detection device is faulted, the
keypad emits a brief tone and displays the
point text of the point tested for 60 sec. After
60 sec, the display returns to the ### PTS TO
TEST message.
Extra Points display default text: If the switches
on a POPIT are set incorrectly to a point number
that is not in the program for the control panel,
the default text for that point number (PT ###)
appears when the point is faulted. Refer to the
control panel’s program record sheet for the
default text for all points.
Faulting the point a second time produces the
tone and shows the point text, but does not
decrease the count in the ## PTS TO TEST
message.
To see the points that remain untested during the
Service Walk Test:
a. Press [ESC] when point text appears. The
display shows ## PTS TO TEST.
b. Press the [ESC] key. VIEW UNTESTED ?
appears.
c. Press [ENT]. ## PTS UNTESTED appears.