Installation guide

6. Connect Wiring
f
WARMING:
Use only spring type wire nuts (included) to make
electrical connections. Replacement wire nuts must be
rated for a minimum of (2) #!8ga wires and a maximum
of 4 #!4ga wires, UL A CSA rated to 600V and 3020 Fi
!500 C. Request #189692 when ordering from
BSH.
For Internal Blower Use:
See Figure ! or 2, page 3.
!. Remove electrical knockout behind ] box and
install !/2" conduit connectors.
2. Run !20V AC 60Hz, !5A supply wires through !/2"
conduit to hood electrical knockout behind ] box
cover
3. Connect blower cord wires to house wiring through
electrical knockouts. Use wire nuts supplied (white
to white, black to black, green to green).
4. Connect blower cord at white connector behind
connector access panel (if not already connected).
Verify that connectors are tightly connected.
For Remote Blower Use:
See Figure 3, page 3.
!. Remove 2 hood electrical knockouts and install
!/2" conduit connectors.
2. Run black, white and green supply wires through
!/2" conduit to hood electrical knockout behind
] box.
3. Connect power supply wires to hood wires behind
] box (white to white, black to black, green to
green). Use wire nuts supplied.
4. Run 5 wires (#!4 AWG) in !/2" conduit from the
remote blower to the electrical knockout behind
the remote wire cover.
5. Connect remote blower wiring to"pigtail" wires
behind remote wire cover with wire nuts supplied
(white to white, black to black, green to green and
black to brown, white to white, red to red and
blue to blue) See Figure 6.
6. Connect other end of "pigtail" at white connector.
Verify that connectors are tightly connected.
® Reassemble Hood
Reattach the following:
1. Connector access panel (internal blower only)
2. J box
3. Remote wire cover (remote blower use only)
4. Back filter rail
5. Filters
Accessories
The following accessories are available from your Bosch
dealer or through Bosch Service: 800-944-2904. Please
reference the model number when requesting these items.
6" Duct Covers " 30" ' 36"
Biscuit DCZ7607UC NiA
Black DCZ7606UC DCZ9666UC
Stainless Steel DCZ7605UC DCZ9665UC
White DCZ7602UC DCZ9662UC
12" Duct Covers ° 30" " 36"
Biscuit
Black
Stainless Steel
White
Recirculation Kit
Biscuit
Black
Stainless Steel
White
Charcoal Filter
3 i 4 x!OTransition
DCZ7207UC NiA
DCZ7206UC DCZ9266UC
DCZ7205UC DCZ9265UC
DCZ7202UC DCZ9262UC
30" 36"
DRZ7007UC N/A
DRZ7006UC DRZ9066UC
DRZ7005UC DRZ9065UC
DRZ7002UC DRZ9062UC
DHZ7960UC
DHZ3410UC
Blowers* -
Integral Blower, 400 CFH DHG4001UC
Integral Blower r 600 CFM DHG6001UC
Remote Blower, 600 CFM DHG6003UC
Remote Blower, 1000 CFM DHG1003UC
*for use with DAH95 models onl
Figure 6 - Remote Blower PigtailAssembly
N GND L1
i _ BLACK
WHITE
BROWN
RED
, BLUE \
5