DIVAR IP 6000 2U DIP-6080-00N, DIP-6082-8HD en Quick Installation Guide
DIVAR IP 6000 2U Table of Contents | en 3 Table of contents 1 Safety precautions 4 1.1 General safety precautions 4 1.2 Electrical safety precautions 5 1.3 ESD precautions 6 1.4 Operating precautions 6 1.5 Important notices 7 1.6 FCC and ICES compliance 7 2 System overview 8 2.1 System interface 3 System setup - hardware 10 3.1 Introduction 10 3.2 Unpacking the system 10 3.3 Preparing for setup 10 3.3.1 Choosing a setup location 10 3.3.2 Rack precautions 10 3.
en | Safety precautions DIVAR IP 6000 2U Safety precautions 1 Observe the safety precautions in this chapter. 1.1 General safety precautions Follow these rules to ensure general safety: – Keep the area around the system clean and free of clutter. – Place the chassis top cover and any system components that have been removed away from the system or on a table so that they won't accidentally be stepped on.
DIVAR IP 6000 2U Safety precautions | en 5 Warning! Lithium battery: Batteries that have been inserted wrongly can cause an explosion. Always replace empty ! batteries with batteries of the same type or a similar type recommended by the manufacturer. Handle used batteries carefully. Do not damage the battery in any way. A damaged battery may release hazardous materials into the environment. Dispose of empty batteries according to the manufacturer's instructions.
en | Safety precautions – DIVAR IP 6000 2U Use only one hand when working with powered-on electrical equipment. This is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with. – The power supply power cords must include a grounding plug and must be plugged into grounded electrical outlets. The unit has more than one power supply cord.
DIVAR IP 6000 2U Safety precautions | en 7 Note: Please handle used batteries carefully. Do not damage the battery in any way. A damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly. 1.5 Important notices Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount.
en | System overview 2 DIVAR IP 6000 2U System overview DIVAR IP 6000 is an affordable, simple and reliable all-in-one recording management solution for network surveillance systems of up to 64 cameras. Powered by VRM (Video Recording Manager) software, the system is an intelligent IP storage device that eliminates the need for separate NVR (Network Video Recorder) server and storage hardware.
DIVAR IP 6000 2U System overview | en 9 Rear view: 2 1 1 3 4 5 2x mains connection 100 – 240 VAC, 6 4 Serial interface COM1 50 - 60 Hz 2 2x PS/2 5 Monitor (VGA) 3 2x USB 6 2x Ethernet (RJ45) Bosch Sicherheitssysteme GmbH Quick Installation Guide 2013.
en | System setup - hardware DIVAR IP 6000 2U 3 System setup - hardware 3.1 Introduction Scope of delivery: – DIVAR IP 6000 – 8-bay system, fully equipped with 8 hard drives (DIP‑6082‑8HD) – In addition to the system itself, the following items should have been shipped along with each system 3.
DIVAR IP 6000 2U System setup - hardware | en – 11 Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. – In single rack installations, attach stabilizers to the rack. – If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. – This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
en | System setup - hardware 3.4 DIVAR IP 6000 2U Rack mounting instructions This section provides information on installing the chassis into a rack unit. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using. Notice! This rail will fit a rack between 26" and 33.5" deep. 3.4.
DIVAR IP 6000 2U System setup - hardware | en 4. 3.4.2 13 Separate the inner rail extension from the outer rail assembly. Installing the inner rails The chassis includes a set of inner rails in two sections: inner rails and inner rail extensions. The inner rails are pre-attached to the chassis, and do not interfere with normal use of the chassis if you decide not to use a server rack. The inner rail extension is attached to the inner rail to mount the chassis in the rack.
en | System setup - hardware DIVAR IP 6000 2U To install the outer rails to the rack: 1. Secure the back end of the outer rail to the rack, using the screws provided. 2. Press the button where the two outer rails are joined to retract the smaller outer rail. 3. Hang the hooks of the rails onto the rack holes and if desired, use screws to secure the front of the outer rail onto the rack. 4. Repeat steps 1-3 for the remaining outer rail.
DIVAR IP 6000 2U 3.4.5 System setup - hardware | en 15 Installing the chassis into a Telco rack To install the chassis into a Telco type rack, use two L-shaped brackets on either side of the chassis (four in total). First, determine how far the chassis will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on the chassis, remove it.
en | System Setup – first Steps DIVAR IP 6000 2U 4 System Setup – first Steps 4.1 Introduction The following installation directive provides information on Installation and Configuration. The DIVAR IP 6000 systems are based on Windows Storage Server 2008 R2 operating system.
System Setup – first Steps | en DIVAR IP 6000 2U 2. 17 Open the Remote Desktop Connection on your client system. In the Computer box, enter the IP Address of the disk array you want to connect to. Default IP Address: 10.10.10.10 (port 1) 3. Click Connect, press Ctrl+Alt+Del (if shown), then type the default password WSS4Bosch once the disk array login window is displayed. To configure the IP address: 1. After starting the system, on first login the desktop default settings are applied.
en | System Setup – first Steps DIVAR IP 6000 2U For each network port a separate icon is shown. Select the Local Area Connection icon that shows the status network, then double-click the icon. 3. Click Properties, select Internet Protocol Version 4 (TCP/IPv4), then click Properties. 4. This dialog box allows you to set the IP address configuration according to the requirements of your network. 5. 2013.05 | V3 | DOC Reboot the system.
DIVAR IP 6000 2U 4.3.2 System Setup – first Steps | en 19 Physical connection To start the system: The system comes with a VGA graphic connector and with PS2 connectors for mouse and keyboard. 1. Connect a monitor, mouse and keyboard (not part of the shipment) to the disk array and start up the system. Note: When connecting a PS2 mouse or keyboard device after the system has been booted it will most likely not operate properly. 2.
en | System Setup – first Steps DIVAR IP 6000 2U 3. Click Properties, select Internet Protocol Version 4 (TCP/IPv4), then click Properties. 4. This dialog box allows you to set the IP address configuration according to the requirements of your network. 5. 2013.05 | V3 | DOC Reboot the system.
DIVAR IP 6000 2U System Setup – first Steps | en 4.4 VRM Appliance 4.4.1 Default installation 21 The system is pre-installed with the Bosch Video Recording Manager (VRM) and fully licensed with a 64 channel license. This license might be expanded by a maximum of another 64 channels. VRM provides a powerful recording engine to be used with the Video Client or Bosch VMS for live viewing and replay of recorded data.
en | Additional software and documentation 5 DIVAR IP 6000 2U Additional software and documentation Software for configuration of hardware and software (VRM) is available on the VRM Appliance in folder C:\Bosch\resources. VRM Configurator: Software for easy configuration of VRM including disk array, cameras, recording scheduler and other components. Should be installed on a separate Client system, for example Bosch workstation hardware.
DIVAR IP 6000 2U 6 Service and repair | en 23 Service and repair The storage system is backed by a 3-year warranty. Issues will be handled according to Bosch Support and Service guidelines. The standard Bosch support way of working applies. The following modules may be replaced on-site in case of a failure without returning the unit: – Hard drives: As replacement hard drives only original Bosch hard drives are supported. Otherwise the warranty is void.
Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.