DIVAR IP 6000 (2U) DIP-6180-00N | DIP-6183-4HD | DIP-6183-8HD | DIP-6184-4HD | DIP-6184-8HD | DIP-6186-8HD | DIP-6188-8HD en Installation Manual
DIVAR IP 6000 (2U) Table of contents | en 3 Table of contents 1 Safety information 5 1.1 Safety message explanation 5 1.2 Safety precautions 5 1.3 Important safety instructions 6 1.4 Electrical safety precautions 8 1.5 ESD precautions 9 1.6 Operating precautions 9 1.7 Notices 1.8 FCC and ICES compliance 10 2 About this manual 12 3 System overview 13 3.1 Chassis features 13 3.2 Chassis components 13 3.2.1 Chassis 13 3.2.2 Fans 13 3.2.3 Power supply 13 3.2.
en | Table of contents DIVAR IP 6000 (2U) 9.2 MS-PL - MSDN Library 30 9.3 NTP License - NTP Project 31 10 Maintenance 32 10.1 Replacement components 32 10.2 Removing power from the system 32 10.3 Removing the chassis cover 32 10.4 Installing a SATA hard drive 33 10.4.1 Removing a hard drive from the chassis 33 10.4.2 Installing a hard drive into a hard drive carrier 34 10.4.3 Installing a hard drive into a front drive bay 35 10.5 Identifying a faulty SSD drive 35 10.
DIVAR IP 6000 (2U) 1 Safety information | en 5 Safety information Observe the safety notes in this chapter. 1.1 Safety message explanation Warning! ! Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Caution! ! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Notice! Indicates a situation which, if not avoided, could result in damage to the equipment or environment, or data loss. 1.
en | Safety information DIVAR IP 6000 (2U) Warning! Interruption of mains supply: ! Voltage is applied as soon as the mains plug is inserted into the mains socket. However, for devices with a mains switch, the device is only ready for operation when the mains switch (ON/OFF) is in the ON position. When the mains plug is pulled out of the socket, the supply of power to the device is completely interrupted.
DIVAR IP 6000 (2U) Safety information | en – 7 Do not install device near any heat sources such as radiators, heaters, stoves, or other equipment (including amplifiers) that produce heat. – Never spill liquid of any kind on the device. – Take precautions to protect the device from power and lightning surges. – Unless qualified, do not attempt to service a damaged device yourself. Refer all servicing to qualified service personnel.
en | Safety information – DIVAR IP 6000 (2U) Disconnect the power before moving the unit. Move the unit with care. Excessive force or shock may damage the unit and the hard disk drives. – All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits. – If safe operation of the unit cannot be ensured, remove it from service and secure it to prevent unauthorized operation.
DIVAR IP 6000 (2U) Safety information | en 9 Caution! ! 1.5 DVD-ROM Laser: To prevent direct exposure to the laser beam and hazardous radiation exposure, do not open the enclosure or use the unit in any unconventional way. ESD precautions Notice! Electrostatic Discharge (ESD) can damage electronic components. To prevent damage to your system, it is important to handle the electronic components very carefully.
en | Safety information DIVAR IP 6000 (2U) Notice! Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of losing information, we recommend multiple, redundant recording systems, and a procedure to back up all analog and digital information. Disposal Your Bosch product has been developed and manufactured using highquality materials and components that can be reused.
DIVAR IP 6000 (2U) Safety information | en 11 not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense. Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.
en | About this manual 2 DIVAR IP 6000 (2U) About this manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the chassis. Installation and maintenance should be performed by experienced and qualified technicians only. 2016.08 | V2.
DIVAR IP 6000 (2U) System overview | en 3 System overview 3.1 Chassis features 13 The high-performance chassis includes the following features: – Hard drives The chassis features 8 slots for SATA drives. These drives are hot swappable. Once set up correctly, these drives can be removed without powering down the unit. In addition, these drives support SES2 (SATA). – I/O expansion slots Each chassis model includes seven low-profile I/O expansion slots.
en | System overview 3.3 DIVAR IP 6000 (2U) System interface There are several LEDs on the front and rear of the chassis. The LEDs show the over-all status of the system and the activity and health of specific components. Front view: 1 3 2 4 5 6 1 2x USB 2.
DIVAR IP 6000 (2U) System overview | en 5 4 USB ports 6 (2x USB 2.0 and 2x USB 3.0) 15 2x network ports for data transmission (teamed) Note: Do not change the teaming mode! 7 3.3.1 1x VGA display output Control panel buttons There are two push-buttons located on the front of the chassis. These are (in order from left to right) a reset button and a power on/off button. – Reset: The reset button is used to reboot the system.
en | System overview DIVAR IP 6000 (2U) – NiC2: A flashing LED indicates network activity on GLAN2. – NIC1: A flashing LED indicates network activity on GLAN1. – HDD: A flashing LED indicates IDE channel activity in the SAS/SATA drive, SCSI drive, and/or DVD-ROM drive activity. – Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating. 3.3.3 Drive carrier LEDs Your chassis uses SATA drives.
DIVAR IP 6000 (2U) Rack installation | en 4 Rack installation 4.1 Unpacking the system 17 You should inspect the box the chassis was shipped in and note if it was damaged in any way. If the chassis itself shows damage, file a damage claim with the carrier who delivered it and notify the respective Bosch RMA desk. Due to the weight of the system: After opening the top of the shipping box, one person should stand at either end and lift the disk array out together.
en | Rack installation 4.2.3 DIVAR IP 6000 (2U) General system precautions – Review the electrical and general safety precautions that came with the components you are adding to your chassis. – Determine the placement of each component in the rack before installing the rails. – Install the heaviest components on the bottom of the rack first, and then work up.
DIVAR IP 6000 (2U) Rack installation | en – an inner fixed chassis rail that secures directly to the chassis – an outer fixed rack rail that secures directly to the rack itself. 19 To separate the inner and outer rails: 4.3.2 1. Locate the rail assembly in the chassis packaging. 2. Extend the rail assembly by pulling it outward. 3. Press the quick-release tab. 4. Separate the inner rail extension from the outer rail assembly.
en | Rack installation DIVAR IP 6000 (2U) 3 1 2 To install the inner rails: 1. Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes. Make sure the extension faces "outward" just like the preattached inner rail. 4.3.3 2. Slide the extension toward the front of the chassis. 3. Secure the chassis with 2 screws as illustrated. 4. Repeat steps 1-3 for the other inner rail extension.
DIVAR IP 6000 (2U) 4.3.4 Rack installation | en 21 Installing the chassis in the rack Warning! ! Stability hazard Before sliding the unit out for servicing make sure that the rack stabilizing mechanism is in place, or the rack is bolted to the floor. Failure to stabilize the rack can cause the rack to tip over. Warning! ! Do not pick up the unit with the front handles. The handles are designed to pull the system from a rack only.
en | Rack installation DIVAR IP 6000 (2U) Warning! ! Stability hazard Before sliding the unit out for servicing make sure that the rack stabilizing mechanism is in place, or the rack is bolted to the floor. Failure to stabilize the rack can cause the rack to tip over. Warning! ! Do not pick up the unit with the front handles. The handles are designed to pull the system from a rack only.
DIVAR IP 6000 (2U) System Setup – first Steps | en 5 System Setup – first Steps 5.1 Introduction 23 The DIVAR IP 6000 systems are based on Windows Storage Server 2012 R2 operating system. Windows Storage Server 2012 R2 systems provide a user interface for initial server configuration, unified storage appliance management, simplified setup and storage management, and support for Microsoft iSCSI Software Target. It is specially tuned to provide optimal performance for network-attached storage.
en | System Setup – first Steps DIVAR IP 6000 (2U) – in the online catalog on the DIVAR IP 6000 product page – under http://mydivar.com – under http://downloadstore.boschsecurity.com/ To start the IP Helper tool: 1. Double-click iphelper.exe. 2. A dialog box opens that displays all IP devices with their IP addresses located in the network. Search for the devices whose network settings you want change. 3. 5.4 Change the IP address.
DIVAR IP 6000 (2U) 6 RAID setup | en 25 RAID setup If you have added third party hard drives to empty units, you must configure the hard drives using the RAID setup utility. The RAID setup utility is pre-installed on the system. Notice! The RAID setup process is not necessary for units with pre-installed hard drives. These units are delivered with a default configuration. DIVAR IP systems are configured in RAID 5 mode by default. Alternatively, RAID 5+ or RAID 6 can be used.
en | RAID setup DIVAR IP 6000 (2U) See also – 6.2 Setting the IP address, page 23 RAID setup using RAID BIOS To configure the hard drive using RAID BIOS: 1. Install all hard drives. 2. Turn on the system and press Ctrl+R when MegaRAID Configuration Utility is displayed on the screen. The display appears before Windows starts. 3. In the MegaRAID Configuration Utility program, select Create Virtual Drive. 4.
DIVAR IP 6000 (2U) 7 Recovering the unit | en 27 Recovering the unit Following procedure describes how to restore the factory default image. To restore the unit to factory default image 1. Turn on the unit and insert the system recovery DVD. Notice! Make sure that a VGA monitor, a keyboard and a mouse are connected to the unit. 2. Press any key when prompted to start the recovery environment from DVD. Note: Press any key only to start the recovery environment.
en | Additional software and documentation 8 DIVAR IP 6000 (2U) Additional software and documentation Software for configuration of hardware and software is available on the online product catalogue. Documentation and software for Bosch Security Systems products can be found in the online product catalogue as follows: 4 Open any browser > enter www.boschsecurity.
DIVAR IP 6000 (2U) 9 OSS licenses | en 29 OSS licenses This chapter provides an overview on used Open Source Licenses in DIVAR IP 6000. The license packages are either used completely or only some parts within a package are used. 9.1 MIT - iniparser Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.
en | OSS licenses 9.2 2016.08 | V2.
DIVAR IP 6000 (2U) 9.3 OSS licenses | en 31 NTP License - NTP Project Bosch Sicherheitssysteme GmbH Installation Manual 2016.08 | V2.
en | Maintenance 10 DIVAR IP 6000 (2U) Maintenance This chapter covers the steps required to install components and perform maintenance on the chassis. Notice! Installation should only be carried out by qualified customer service personnel in accordance with the applicable electrical regulations. Caution! ! 10.1 Review the warnings and precautions listed in the manual before setting up or servicing this chassis.
DIVAR IP 6000 (2U) Maintenance | en 1 Fixing screws 3 Chassis cover 2 33 Release tabs To remove the chassis cover: 1. Disconnect the power supply, lay the chassis on a flat surface. 2. Remove the two screws on each side of the cover, which secure the cover to the chassis. 3. Press the release tabs to remove the cover from the locked position. Press both tabs at the same time. 4.
en | Maintenance DIVAR IP 6000 (2U) 2. Use the handle to pull the drive out of the chassis. Notice! Except for short periods of time (swapping hard drives), do not operate the unit with the hard drives removed from the bays. 10.4.2 Installing a hard drive into a hard drive carrier The hard drives are mounted in hard drive carriers. To install a hard drive into a hard drive carrier: 1. Remove the screws securing the dummy drive to the hard drive carrier. 2.
DIVAR IP 6000 (2U) Maintenance | en 1 6. Hard drive carrier 2 35 SATA hard drive Replace the hard drive carrier into the chassis bay. Make sure that the hard drive carrier handle is completely closed. Notice! We recommend using the respective Bosch hard disk drives. The hard disk drives as one of the critical component are carefully selected by Bosch based on available failure rates. HDD – not delivered from Bosch – are not supported.
en | Maintenance 10.6 DIVAR IP 6000 (2U) Installing a SSD hard drive into a rear drive bay This chapter describes the removing and installing of SSD hard drives on the rear side of the chassis. 10.6.1 Removing a hard drive from the rear drive bay The unit features two hot-swappable hard drives on the rear side which can be removed without powering down the system. The hard drives are mounted in hard drive carriers to simplify their installation and removal from the chassis.
DIVAR IP 6000 (2U) Maintenance | en 5. 37 Secure the hard drive to the hard drive carrier with four screws. Use the four M3 flat-head screws included in the hard disk bag of your accessory box. Note: To secure the hard drive, you cannot reuse the screws that are used to secure the dummy drive to the tray. Notice! We recommend using the respective Bosch hard disk drives. The hard disk drives as one of the critical component are carefully selected by Bosch based on available failure rates.
en | Maintenance DIVAR IP 6000 (2U) 1 1 DVD-ROM 2 2 Front port panel To replace the front port panel: 1. Turn off and unplug the unit. 2. Remove the chassis cover. 3. Disconnect the power and data cables from the front port panel to other chassis components including the motherboard and backplane. 4. Remove the old port panel by depressing the release tab, then pulling the unit out of the chassis. 10.9 5. Insert the new front port panel unit in the slot until the tab locks into place.
DIVAR IP 6000 (2U) Maintenance | en 39 To check the air flow: 1. Make sure there are no objects to obstruct airflow in and out of the chassis. In addition, if you are using a front bezel, make sure the bezel's filter is replaced periodically. 2. Do not operate the system without drives or drive trays in the drive bays. Use only recommended material. 3. Make sure no wires or foreign objects obstruct air flow through the chassis. Pull all excess cabling out of the airflow path or use shorter cables.
en | Maintenance DIVAR IP 6000 (2U) To replace a system fan: 1. If necessary, open the chassis while the power is running to determine which fan has failed. Note: Never run the system for an extended period of time with the chassis open. 2. Turn off the power to the system and unplug the power cord from the outlet. 3. Remove the failed fan's power cord from the motherboard. 4. Press the fan release tab to lift the failed fan from the chassis and pull it completely from the chassis.
DIVAR IP 6000 (2U) Maintenance | en 41 See also – 10.12.1 Power supply, page 13 Replacing the power supply The power supply can be replaced without turning off the system if a redundant power supply is available. Replacement units can be ordered directly from Bosch RMA desk. To replace the power supply: 1. You can leave the unit running and remove only one power supply if your chassis includes a redundant power supply. 10.12.2 2. Unplug the AC power cord of the failed power supply. 3.
en | Maintenance DIVAR IP 6000 (2U) To replace the power distributor: 1. Turn off the unit and remove the plug from the wall socket or power strip. 2. Remove all cable connections to the power supply from the motherboard, backplane, and other components. Also, remove both power supplies. 3. Locate the power distributor between the power supply and the fan row. 4. Remove the three screws securing the power supply. 5. Gently pull the power distributor from the chassis.
DIVAR IP 6000 (2U) Maintenance | en 43 Notice! For detailed information using the program, refer to the Video Recording Manager documentation. 10.15 Service and repair The storage system is backed by a 3-year warranty. Issues will be handled according to Bosch Service and Support guidelines. The storage equipment is shipped with an original manufacturer Service and Support agreement.
Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.