DIVAR IP 7000 (2U) DIP-7180-00N | DIP-7183-4HD | DIP-7183-8HD | DIP-7184-4HD | DIP-7184-8HD en Quick Installation Guide
DIVAR IP 7000 (2U) Table of contents | en 3 Table of contents 1 Safety precautions 4 1.1 General safety precautions 4 1.2 Electrical safety precautions 5 1.3 ESD precautions 6 1.4 Operating precautions 6 1.5 Important notices 7 1.6 FCC and ICES compliance 7 2 About this manual 8 3 System overview 4 System setup - hardware 11 4.1 Unpacking the system 11 4.2 Preparing for setup 11 4.2.1 Choosing a setup location 11 4.2.2 Rack precautions 11 4.2.
en | Safety precautions 1 DIVAR IP 7000 (2U) Safety precautions Observe the safety precautions in this chapter. 1.1 General safety precautions Follow these rules to ensure general safety: – Keep the area around the system clean and free of clutter. – Place the chassis top cover and any system components that have been removed away from the system or on a table so that they won't accidentally be stepped on.
DIVAR IP 7000 (2U) Safety precautions | en 5 Warning! ! Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm. Notice! Electrostatically sensitive device: To avoid electrostatic discharges, the CMOS/MOSFET protection measures must be carried out correctly.
en | Safety precautions – DIVAR IP 7000 (2U) Mainboard replaceable soldered-in fuses: Self-resetting PTC (Positive Temperature Coefficient) fuses on the mainboard must be replaced by trained service technicians only. The new fuse must be the same or equivalent as the one replaced. Contact technical support for details and support. Caution! ! Mainboard Battery: There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarities.
DIVAR IP 7000 (2U) Safety precautions | en 7 Note: Please handle used batteries carefully. Do not damage the battery in any way. A damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly. 1.5 Important notices Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount.
en | About this manual 2 DIVAR IP 7000 (2U) About this manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the chassis. Installation and maintenance should be performed by experienced and qualified technicians only. 2015.
DIVAR IP 7000 (2U) 3 System overview | en 9 System overview DIVAR IP 7000 is an affordable, simple and reliable all-in-one recording, viewing and management solution for network surveillance systems of up to 128 channels (with 32 channels pre-licensed).
en | System overview DIVAR IP 7000 (2U) Rear view: 1 1 2 3 4 5 6 2x power supply modules 8 7 2 9 2x redundant SSD drives for operating system (RAID1 mirror) 3 1x serial port 4 1x network port for BMC (Baseboard Management Controller) connection and IPMI (Intelligent Platform Management Interface) monitoring 5 4 USB 3.
DIVAR IP 7000 (2U) System setup - hardware | en 4 System setup - hardware 4.1 Unpacking the system 11 You should inspect the box the chassis was shipped in and note if it was damaged in any way. If the chassis itself shows damage, file a damage claim with the carrier who delivered it and notify the respective Bosch RMA desk. Due to the weight of the system: After opening the top of the shipping box, one person should stand at either end and lift the disk array out together.
en | System setup - hardware 4.2.3 DIVAR IP 7000 (2U) General system precautions – Review the electrical and general safety precautions that came with the components you are adding to your chassis. – Determine the placement of each component in the rack before installing the rails. – Install the heaviest components on the bottom of the rack first, and then work up.
DIVAR IP 7000 (2U) System setup - hardware | en – an inner fixed chassis rail that secures directly to the chassis – an outer fixed rack rail that secures directly to the rack itself. 13 To separate the inner and outer rails: 4.3.2 1. Locate the rail assembly in the chassis packaging. 2. Extend the rail assembly by pulling it outward. 3. Press the quick-release tab. 4. Separate the inner rail extension from the outer rail assembly.
en | System setup - hardware DIVAR IP 7000 (2U) 3 1 2 To install the inner rails: 1. Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes. Make sure the extension faces "outward" just like the preattached inner rail. 4.3.3 2. Slide the extension toward the front of the chassis. 3. Secure the chassis with 2 screws as illustrated. 4. Repeat steps 1-3 for the other inner rail extension.
DIVAR IP 7000 (2U) 4.3.4 System setup - hardware | en 15 Installing the chassis in the rack Warning! ! Stability hazard Before sliding the unit out for servicing make sure that the rack stabilizing mechanism is in place, or the rack is bolted to the floor. Failure to stabilize the rack can cause the rack to tip over. Warning! ! Do not pick up the unit with the front handles. The handles are designed to pull the system from a rack only.
en | System setup - hardware 4.3.5 DIVAR IP 7000 (2U) Installing the chassis in a Telco rack Notice! Do not use a two post "Telco" type rack. Warning! ! Stability hazard Before sliding the unit out for servicing make sure that the rack stabilizing mechanism is in place, or the rack is bolted to the floor. Failure to stabilize the rack can cause the rack to tip over. Warning! ! Do not pick up the unit with the front handles. The handles are designed to pull the system from a rack only.
DIVAR IP 7000 (2U) System setup - first steps | en 5 System setup - first steps 5.1 Introduction 17 The DIVAR IP 7000 systems are based on Windows Storage Server 2012 R2 operating system. Windows Storage Server 2012 R2 systems provide a user interface for initial server configuration, unified storage appliance management, simplified setup and management of storage and shared folders, and support for Microsoft iSCSI Software Target.
en | System setup - first steps DIVAR IP 7000 (2U) The software selection screen is displayed. Note: In case of password loss a system recovery must be performed as described in the installation manual. The configuration must be done from scratch or must be imported. 9. Click the version of the video management system that is pre-loaded on the system hard drive or import the software from removable media, for example DVD or USB drive. Note: We recommend that you install the latest version.
DIVAR IP 7000 (2U) System setup - first steps | en 2. 19 Follow the wizard and observe the instructions on the screen. Notice! For the tasks that cannot be done with Configuration Wizard, and for detailed information concerning Configuration Wizard itself, refer to the Bosch VMS manual (see Additional Documentation and client software). 5.5 Using Bosch VMS Operator Client Use Bosch VMS Operator Client to verify the live, recording and playback functionality of DIVAR IP.
en | Additional documentation and client software 6 DIVAR IP 7000 (2U) Additional documentation and client software Documentation and software for Bosch Security Systems products can be found in the online product catalogue as follows: 4 Open any browser > enter www.boschsecurity.com > select your region and your country > start a search for your product > select the product in the search results to show the existing files. 2015.
DIVAR IP 7000 (2U) 7 Service and repair | en 21 Service and repair The storage system is backed by a 3-year warranty. Issues will be handled according to Bosch Service and Support guidelines. The storage equipment is shipped with an original manufacturer Service and Support agreement. Bosch RMA Desk is the Single Point of Contact in case of failure but the Service and Support obligations are fulfilled by the manufacturer or a partner.
Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.