DIVAR IP all‑in‑one 7000 2U DIP‑7380‑00N | DIP‑7384‑8HD | DIP‑7388‑8HD | DIP‑738C‑8HD en Installation manual
DIVAR IP all-in-one 7000 2U Table of contents | en 3 Table of contents 1 Safety 5 1.1 Safety message explanation 5 1.2 General safety precautions 5 1.3 Electrical safety precautions 8 1.4 ESD precautions 9 1.5 Operating precautions 9 1.6 Notices 1.7 FCC and ICES compliance 10 1.8 Data security precautions 10 2 About this manual 12 3 System overview 13 3.1 Chassis components 13 3.2 Device views 13 3.3 Control panel elements 15 3.4 Hard drive carrier LEDs 16 3.
en | Table of contents DIVAR IP all-in-one 7000 2U 10.5.3 Installing a hard drive carrier into a rear hard drive bay 34 10.6 Replacing the DVD ROM drive 34 10.7 Replacing the fron port panel 35 10.8 Installing the motherboard 35 10.9 Installing the air shroud 36 10.10 Replacing a system fan 36 10.11 Replacing the power supply 37 10.12 Replacing the power distributor 38 10.13 Service and repair 39 11 Additional information 40 11.
DIVAR IP all-in-one 7000 2U 1 Safety | en 5 Safety Observe the safety precautions in this chapter. 1.1 Safety message explanation Warning! ! Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Caution! ! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Notice! i 1.2 Indicates a situation which, if not avoided, could result in damage to the equipment or environment, or data loss.
en | Safety DIVAR IP all-in-one 7000 2U Warning! Interruption of mains supply: ! Voltage is applied as soon as the mains plug is inserted into the mains socket. However, for devices with a mains switch, the device is only ready for operation when the mains switch (ON/OFF) is in the ON position. When the mains plug is pulled out of the socket, the supply of power to the device is completely interrupted.
DIVAR IP all-in-one 7000 2U Safety | en 7 – Never spill liquid of any kind on the device. – Take precautions to protect the device from power and lightning surges. – Unless qualified, do not attempt to service a damaged device yourself. Refer all servicing to qualified service personnel. – Install in accordance with the manufacturer's instructions in accordance with applicable local codes. – Use only attachments/accessories specified by the manufacturer.
en | Safety DIVAR IP all-in-one 7000 2U – All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits. – If safe operation of the unit cannot be ensured, remove it from service and secure it to prevent unauthorized operation. In such cases, have the unit checked by Bosch Security Systems.
DIVAR IP all-in-one 7000 2U Safety | en 9 Caution! ! 1.4 DVD-ROM Laser: To prevent direct exposure to the laser beam and hazardous radiation exposure, do not open the enclosure or use the unit in any unconventional way. ESD precautions Notice! i Electrostatic Discharge (ESD) can damage electronic components. To prevent damage to your system, it is important to handle the electronic components very carefully.
en | Safety DIVAR IP all-in-one 7000 2U Disposal Your Bosch product has been developed and manufactured using high-quality materials and components that can be reused. This symbol means that electronic and electrical devices that have reached the end of their working life must be disposed of separately from household waste. In the EU, separate collecting systems are already in place for used electrical and electronic products.
DIVAR IP all-in-one 7000 2U – Safety | en 11 Physical access to the system shall be restricted to authorized personnel only. It is strongly suggested to place the system in an access control protected area, in order to avoid physical manipulation of the system. – Windows online update functionality or the corresponding monthly roll-up patches for offline installation can be used to install OS security updates. – Limiting local network access to trusted devices is strongly suggested.
en | About this manual 2 DIVAR IP all-in-one 7000 2U About this manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the chassis. Installation and maintenance should be performed by experienced and qualified technicians only. 2020.11 | V1.1 | DOC Installation manual Bosch Security Systems B.V.
DIVAR IP all-in-one 7000 2U System overview | en 3 System overview 3.1 Chassis components 13 This chapter describes the most common components included with your chassis. For more information, see the installation instructions detailed later in this manual. Component Description Hard drives The chassis includes 8 hard drive bays for SATA hard drives. These hard drives are hot swappable. Once setup correctly, these drives can be removed without turning off the system.
en | System overview DIVAR IP all-in-one 7000 2U Front view: 1 2 3 4 5 6 7 1 2 USB 2.0 ports 2 Power failure LED 3 Information LED 4 NIC1 and NIC2 LEDs 5 HDD (drive activity) LED 6 Power LED 7 Reset button 8 Power button 9 Hard drive carrier LEDs 8 9 Rear view: 1 1 2 3 4 5 6 7 2 power supply modules 8 9 2 10 11 2 redundant SSD drives for operating system (RAID1 mirror) 3 IPMI LAN 4 3 USB ports 3.1 Gen 2 (Type A) 5 USB port 3.
DIVAR IP all-in-one 7000 2U 3.3 System overview | en 15 Control panel elements The control panel located on the front of the chassis features power buttons and status monitoring LEDs. Control panel buttons Button Description The power button is used to apply or remove power from the power supply to the system. Power Note: Turning off system power with this button removes the main power, but keeps standby power supplied to the system.
en | System overview DIVAR IP all-in-one 7000 2U LED Description This LED indicates activity on the HDDs or peripheral drives when flashing. HDD This LED indicates that power is being supplied to the system's power supply units. Power 3.4 This LED should normally be illuminated when the system is operating. Hard drive carrier LEDs The chassis supports hot-swappable SAS/SATA hard drives in hard drive carriers.
DIVAR IP all-in-one 7000 2U 4 Preparing for installation | en 17 Preparing for installation Read this section in its entirety before you begin the installation. 4.1 Choosing the installation location – Place the system near at least one grounded power outlet. – Place the system in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated.
en | Preparing for installation – DIVAR IP all-in-one 7000 2U Always keep the rack’s front door and all panels and components on the system closed when not servicing to maintain proper cooling. 4.4 Installation considerations Ambient operating temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room.
DIVAR IP all-in-one 7000 2U 5 Rack installation | en 19 Rack installation This section provides information on installing the chassis into a rack unit. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. Also refer to the installation instructions that came with the rack unit you are using. Notice! i 5.1 This rail will fit a rack between 26" and 33.5" deep.
en | Rack installation 5.2 DIVAR IP all-in-one 7000 2U Installing the inner rails on the chassis The chassis includes a set of inner rails in two sections: inner rails and inner rail extensions. The inner rails are pre-attached to the chassis, and do not interfere with normal use of the chassis if you decide not to use a server rack. The inner rail extension is attached to the inner rail to mount the chassis in the rack. Caution! ! Do not pick up the chassis with the front handles.
DIVAR IP all-in-one 7000 2U Rack installation | en 21 Locking Tabs Both chassis rails have a locking tab, which serves two functions. The first is to lock the system into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the system in place when fully extended from the rack. This prevents the system from coming completely out of the rack when you pull it out for servicing. 5.
en | Rack installation DIVAR IP all-in-one 7000 2U Installing the chassis in a Telco type rack Notice! i Do not use a two post "Telco" type rack. To install the chassis in a Telco type rack: 1. Determine how far the chassis will extend out the front of the rack. Put larger chassis so that the weight between front and back is balanced. If a bezel is included on the chassis, remove it. 2.
DIVAR IP all-in-one 7000 2U 6 Installing a SATA hard drive | en 23 Installing a SATA hard drive The unit has hot-swappable hard drives, which can be removed without turning off the system. The hard drives are mounted in hard drive carriers to simplify their installation and removal from the chassis. These hard drive carriers also help promote proper airflow for the hard drive bays.
en | Installing a SATA hard drive 2. DIVAR IP all-in-one 7000 2U Remove the dummy drive from the hard drive carrier and place the hard drive carrier on a flat surface. 3. Slide a new hard drive into the hard drive carrier with the printed circuit board side facing down. 4. Align the mounting holes in both, the hard drive carrier and the hard drive. 5. Secure the hard drive to the hard drive carrier with the six screws.
DIVAR IP all-in-one 7000 2U 6.3 Installing a SATA hard drive | en 25 Installing a hard drive carrier into a front drive bay To install a hard drive carrier into a hard drive bay: 1. Insert the hard drive carrier horizontally into the hard drive bay, orienting the hard drive carrier so that the release button is on the right. 2. Push the hard drive carrier into the bay until the handle retracts and the hard drive clicks into the locked position. Bosch Security Systems B.V. Installation manual 2020.
en | Turning on the system 7 DIVAR IP all-in-one 7000 2U Turning on the system To turn on the system: 1. Plug the power cord from the power supply unit into a high-quality power strip that offers protection from electrical noise and power surges. Bosch recommends to use an uninterruptible power supply (UPS). 2. 2020.11 | V1.1 | DOC Push the power button on the control panel to turn on the system. Installation manual Bosch Security Systems B.V.
DIVAR IP all-in-one 7000 2U 8 System setup | en 27 System setup The DIVAR IP all-in-one 7000 systems are based on the operating system Microsoft Windows Server IoT 2019 for Storage Standard. The operating system provides an user interface for initial server configuration, unified storage appliance management, simplified setup and storage management, and support for Microsoft iSCSI Software Target. It is specially tuned to provide optimal performance for network-attached storage.
en | System setup DIVAR IP all-in-one 7000 2U Notice! i Recorded video streams need to be configured in a way that the maximum bandwidth of the system (BVMS/VRM base system plus iSCSI storage expansions) is not exceeded. Notice! i 8.4 For further details, refer to the User manual. Preparing hard drives for video recording Systems that come pre-equipped with hard drives from factory are ready to record out-of-thebox.
DIVAR IP all-in-one 7000 2U System setup | en – 29 Initial factory setup: restores to factory default image and deletes all data on the HDDs. or – System Recovery (back to Factory Defaults): restores to factory default image; data on the HDDs will not be deleted. Note: While the System Recovery option doesn't delete video footage stored on the data HDDs, it still replaces the complete OS partition (including VMS settings) with a default configuration.
en | Troubleshooting 9 Troubleshooting 9.1 Overheating DIVAR IP all-in-one 7000 2U Problem Solution An overheating condition has occurred. – Make sure that no cables obstruct the airflow in the system. – The system status LED is continuously on. Make sure that all fans are present and operating normally. – Make sure that the chassis covers are installed. – Make sure that the heat sinks are installed properly. – Make sure that the ambient room temperature is not too high. 2020.
DIVAR IP all-in-one 7000 2U 10 Maintenance | en 31 Maintenance This chapter covers the steps required to install components and perform maintenance on the chassis. Notice! i Installation should only be carried out by qualified customer service personnel in accordance with the applicable electrical regulations. Caution! ! 10.1 Review the warnings and precautions listed in the manual before setting up or servicing this chassis.
en | Maintenance DIVAR IP all-in-one 7000 2U 1 3 2 1 1 Fixing screws 3 Chassis cover 2 Release tabs To remove the chassis cover: 1. Disconnect the power supply, lay the chassis on a flat surface. 2. Remove the two screws on each side of the cover, which secure the cover to the chassis. 3. Press the release tabs to remove the cover from the locked position. Press both tabs at the same time. 4.
DIVAR IP all-in-one 7000 2U 10.5 Maintenance | en 33 Installing a SSD hard drive into a rear drive bay The unit features two hot-swappable hard drives on the rear side which can be removed without powering down the system. The hard drives are mounted in hard drive carriers to simplify their installation and removal from the chassis. These hard drive carriers also help promote proper airflow for the hard drive bays.
en | Maintenance DIVAR IP all-in-one 7000 2U Notice! Bosch recommends using the respective Bosch hard disk drives. The hard disk drives as one i of the critical component are carefully selected by Bosch based on available failure rates. Hard disk drives not delivered from Bosch are not supported. For more information about supported hard disk drives, see the datasheet in the Bosch Online Product Catalog at: www.boschsecurity.com 10.5.
DIVAR IP all-in-one 7000 2U Maintenance | en 1 DVD-ROM 1 2 2 Front port panel 35 To replace the DVD-ROM drive: 1. Turn off the unit and if necessary, remove the unit from the rack. 2. Remove the chassis cover. 3. Unplug the drives power and data cables from the motherboard and/or backplane. 4. Locate the locking tab at the rear (on the left when viewed from front) of the DVD-ROM drive. Push the tab toward the drive and push the drive unit out the front of the chassis. 5.
en | Maintenance 10.9 DIVAR IP all-in-one 7000 2U Installing the air shroud The air shroud does not require screws for its installation. Notice! i If a 16 DIMM (13.68" x 13") motherboard is used, it is necessary to use the optional MCP-310-82502-0N air shroud. To install the air shroud: 1. Make sure that your air shroud matches your chassis model. 2. Turn off the system and remove the cover. 3. Place the air shroud in the chassis.
DIVAR IP all-in-one 7000 2U Maintenance | en 37 To replace a system fan: 1. If necessary, open the chassis while the power is running to determine which fan has failed. Note: Never run the system for an extended period of time with the chassis open. 2. Turn off the power to the system and unplug the power cord from the outlet. 3. Remove the failed fan's power cord from the motherboard. 4. Press the fan release tab to lift the failed fan from the chassis and pull it completely from the chassis.
en | Maintenance DIVAR IP all-in-one 7000 2U The power supply can be replaced without turning off the system if a redundant power supply is available. Replacement units can be ordered directly from Bosch RMA desk. To replace the power supply: 10.12 1. Unplug the AC power cord of the failed power supply. 2. Push the release tab on the back of the power supply. 3. Pull the power supply out using the handle provided. 4. Replace the failed power supply with the same model. 5.
DIVAR IP all-in-one 7000 2U 2. Maintenance | en 39 Remove all cable connections to the power supply from the motherboard, backplane, and other components. Also, remove both power supplies. 3. Locate the power distributor between the power supply and the fan row. 4. Remove the three screws securing the power supply. 5. Gently pull the power distributor from the chassis. Gently guide all the cables through the power distributor housing. 6.
en | Additional information DIVAR IP all-in-one 7000 2U 11 Additional information 11.1 Additional documentation and client software For more information, software downloads, and documentation, visit http:// www.boschsecurity.com and go to the respective product page in the product catalog. You can find the latest software and available upgrade packages in the Download Area of Bosch Security and Safety Systems under: https://downloadstore.boschsecurity.com/ 11.
DIVAR IP all-in-one 7000 2U Bosch Security Systems B.V. Additional information | Installation manual 41 2020.11 | V1.
| Additional information 2020.11 | V1.1 | DOC DIVAR IP all-in-one 7000 2U Installation manual Bosch Security Systems B.V.
Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V.