3.3 Control panel elements
The control panel located on the front of the chassis features power buttons and status
monitoring LEDs.
Control panel buttons
Button Description
Power
The power button is used to apply or remove power from the power supply to
the system.
Note: Turning off system power with this button removes the main power,
but keeps standby power supplied to the system.
To remove all power, unplug the system before performing maintenance
tasks.
Reset
The reset button is used to reboot the system.
Control panel LEDs
The control panel LEDs provide status information about the system.
LED Description
Power failure
This LED indicates that a power supply module has failed.
Information
This LED indicates the system status.
System status Description
Continuously on and red An overheat condition has occurred. (This
may be caused by cable congestion.)
Blinking red (1Hz) Fan failure: check for an inoperative fan.
Blinking red (0.25Hz) Power failure: check for an inoperative
power supply.
Solid blue Local UID has been activated. Use this
function to locate the unit in a rack
environment.
Blinking blue (300msec) Remote UID has been activated. Use this
function to locate the unit from a remote
location.
NIC2
This LED indicates network activity on GLAN2 when flashing.
NIC1
This LED indicates network activity on GLAN1 when flashing.