Installation Manual
Table Of Contents
- Table of contents
- 1 Safety
- 2 About this manual
- 3 System overview
- 4 Preparing for installation
- 5 Rack installation
- 6 Installing a SATA hard drive
- 7 Turning on the system
- 8 System setup
- 9 Troubleshooting
- 10 Maintenance
- 10.1 Replacement components
- 10.2 Removing power from the system
- 10.3 Removing the chassis cover
- 10.4 Identifying a faulty SSD drive
- 10.5 Installing a SSD hard drive into a rear drive bay
- 10.6 Replacing the DVD ROM drive
- 10.7 Replacing the fron port panel
- 10.8 Installing the motherboard
- 10.9 Installing the air shroud
- 10.10 Replacing a system fan
- 10.11 Replacing the power supply
- 10.12 Replacing the power distributor
- 10.13 Service and repair
- 11 Additional information
DIVAR IP all-in-one 7000 2U Rack installation | en 21
Bosch Security Systems B.V.
Installation manual
2020.11 | V1.1 | DOC
Locking Tabs
Both chassis rails have a locking tab, which serves two functions. The first is to lock the
system into place when installed and pushed fully into the rack, which is its normal position.
Secondly, these tabs also lock the system in place when fully extended from the rack. This
prevents the system from coming completely out of the rack when you pull it out for servicing.
5.4 Installing the chassis in the rack
You can install the chassis in a standard rack or in a Telco type rack.
!
Warning!
Stability hazard
Before sliding the unit out for servicing make sure that the rack stabilizing mechanism is in
place, or the rack is bolted to the floor. Failure to stabilize the rack can cause the rack to tip
over.
!
Warning!
Do not pick up the unit with the front handles. The handles are designed to pull the system
from a rack only.
i
Notice!
Mounting the chassis into the rack requires at least two people to support the chassis during
installation. Please follow safety recommendations printed on the rails.
i
Notice!
Always install chassis into racks from the bottom up.
Installing the chassis in a standard rack
To install the chassis in a standard rack:
1. Extend the outer rails.
2. Align the inner rails of the chassis with the outer rails on the rack.
3. Slide the inner rails into the outer rails, keeping the pressure even on both sides.
4. Push the chassis completely into the rack and make sure that it clicks into the locked
position.
5. Optionally, use screws to secure the front of the chassis to the rack.