Divar - Digital Versatile Recorder EN Installation Instructions
Divar | Installation Manual EN | i Divar Digital Versatile Recorder Installation manual Chapters Bosch Security Systems 1. Introduction 2. Quick install 3. Operating instructions 4. Hardware setup 5. Menu system 6 Using the Configuration Tool 7 Menu default values 8.
Divar | Installation Manual EN | ii Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Digital video recorder for security applications . . . . . . . . . . . . . . . . . . . . . . Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . On-screen help . . . . . . . . . . . . . . . . . . . . . . . . . .
Divar | Installation Manual Console port connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Keyboard connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethernet connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External I/O connection . . . . . . . . . . . . . .
Divar | Installation Manual EN | iv SAFETY PRECAUTIONS CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN! CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This label may appear on the bottom of the unit due to space limitations.
Divar | Installation Manual 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over. 13. Unplug this unit during lightning storms or when unused for long periods of time. 14. Refer all servicing to qualified service personnel.
Divar | Installation Manual FCC & ICES INFORMATION EN | vi Reference (U.S.A. and Canadian Models Only) This is a Class B product. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undisired operation. The internal DVD writer is a laser product.
Divar | Installation Manual | Introduction EN | 1-1 CHAPTER 1 Introduction Digital video recorder for security applications The Divar is a video recording system that can record multiple camera signals while simultaneously providing live multiscreen viewing and playback. It combines the functionality of a digital recorder with a multiplexer and a switcher. The unit has comprehensive search (including a smart motion search) and playback facilities for viewing stored video.
Divar | Installation Manual | Introduction EN | 1-2 a web browser on a PC can be used to view live images or playback recordings from a Divar. The PC-based Configuration Tool facilitates the setup of the unit. triple (***) asterix respectively. If your unit has neither of these facilities, then please skip these instructions. ATM/POS transaction data can be recorded and viewed if the Divar is connected to an ATM or POS device via an ATM/POS bridge unit and has a license installed.
Divar | Installation Manual | Introduction EN | 1-3 On-screen help • A 25-pin D-type connector board with screw terminals (used for switching On-screen context-sensitive help is available for all topics. Just press the yellow • A 15-pin D-type connector board with screw terminals (used for PTZ and alarm connections) ALT key for at least one second to see the help text associated with your current activity. Press the escape key to exit help. For more information please visit: www.
Divar | Installation Manual | Introduction EN | 1-4 Associated equipment DVD writer** A typical system could contain the following components (not included with the unit): The following points should be taken into consideration when using the internal DVD writer: • • • • • The DVD writer might not support all CD and DVD media. For a list of A primary monitor for multiscreen monitoring (monitor A). A second monitor for spot/alarm monitoring (monitor B). Cameras with 1 Vpp composite video outputs.
Divar | Installation Manual | Quick install EN | 2-1 CHAPTER 2 Quick install This chapter gives instructions on how to quickly get the unit operational. Make the connections described on the following pages and then enter the relevant data in the quick install menu. The Quick Install menu appears the first time you start the unit. When you have entered the relevant information the unit will be operational.
Divar | Installation Manual | Quick install EN | 2-2 Quick connection DIVAR / 390 Ohm 6 ATM/POS bridge 1 PC x16* AutoDome LAN / WAN 8 RS232 VIDEO IN VIDEO IN Terminator** 9 11 7 SHIELD + CTRL 3 SHIELD + CTRL 4 SHIELD + CTRL 5 SHIELD 1A R 3A E 1B L 3B 2A A 4A 2B Y 4B GND VIDEO OUT SHIELD + CTRL 1 SHIELD + CTRL 2 - VIDEO OUT Storage Array 9 IN 10 GND 11 IN 12 GND 13 IN 14 GND 15 7 IN 16 8 1 2 3 4 5 6 AutoDome 5 4 110 - 240 Vac B 3 A 2 *can be 6, 9 or 16 depending on model Bos
Divar | Installation Manual | Quick install EN | 2-3 Primary connections First-time use 1. Connect the cameras to the BNC loop-through camera inputs (automatically terminated). 2. Connect monitor A to the BNC output MON A. The unit starts with a multiscreen display. The Quick install menu opens the first time you use the unit. Fill in these basic settings to get the unit operational. Select the Install item to save your settings and close the menu.
Divar | Installation Manual | Quick install QUICK INSTALL MENU EN | 2-4 > >> DATE • Fill in the actual date. QUICK INSTALL LANGUAGE ENGLISH TIME ZONE GMT +01:00 WEST EUROPE TIME FORMAT 24-HOUR TIME 19:45:00 DATE FORMAT YYYY-MM-DD DATE 2002-06-20 1 2 3 4 5 >> ACTIVE CAMS • Select the cameras you wish to activate. Only activated cameras are configured after exiting the Quick Install menu. Press the camera keys to select or deselect a camera. A check mark means selected.
Divar | Installation Manual | Quick install EN | 2-5 >> RECORDING SETTINGS • RECORDING SETTINGS DAY PERIOD 8:00 WEEKEND SAT AND SUN REC DAY 1 IPS/CAM REC WEEKEND/NIGHT 2 IPS/CAM ENABLE ALARM INPUTS FOR DAY/NIGHT ALARM INPUT RECORDING 12.5 IPS/INPUT ENABLE MOTION FOR NIGHT 1 2 18:00 3 4 MOTION RECORDING 5 IPS/CAM APPROX. REC.
Divar | Installation Manual | Quick install EN | 2-6 >> APPROXIMATE RECORDING DURATION • This is an estimate of the recording duration based on the total amount of storage space available and the recording setup. For event recording, the following parameters are used: • During the day, one camera is in input alarm recording 5% of the time and every motion enabled camera is in motion recording 10% of the time.
Divar | Installation Manual | Operating instructions EN | 3-1 CHAPTER 3 Operating instructions The instructions in this chapter explain the purpose of the front panel keys. The functions available can be limited by setting passwords. Some functions may also require a software license. An administrator has access to many more functions in the menu. Refer to Chapter 5 - Advanced Menu Setup for a full list of available menu items.
Divar | Installation Manual | Operating instructions EN | 3-2 Front panel controls Divar Bilinx Divar Bilinx Divar Bilinx with internal DVD writer DVD writer Open/Close button Divar Bilinx Bosch Security Systems DVD writer Read/Write LED
Divar | Installation Manual | Operating instructions Indicators EN | 3-3 Keys The power indicator unit. lights to indicate that power is being supplied to the The indicators across the top of the controls light or flash to alert you to various operating conditions. Record - lights when the unit is recording video. Network - lights when a remote user is connected to the unit. Alarm - flashes when an alarm is detected. Motion - flashes when motion is detected in a camera signal.
Divar | Installation Manual | Operating instructions EN | 3-4 Primary functions (light below ALT key off) Live key - press to switch to live viewing. ACK key Search key - press to open a search menu to look for recorded events. Multiscreen key- press to see different monitor display layouts. Reverse key - in live mode, press to start reverse playback of recordings for the displayed cameras. in playback mode, press to speed up rewind. in pause mode, press to step back one frame.
Divar | Installation Manual | Operating instructions EN | 3-5 Alternate functions (light below ALT key is lit) F1 key - restores defaults in active menu. Menu key - opens the menu system. F2 key - is assigned a specific function in some submenus. Mon A key - assigns front panel keys to monitor A. Arrow keys: - move around through menu items or values. Mon B key - assigns front panel keys to monitor B. - Left Sequence key - view cameras in sequence on full-screen or quad displays.
Divar | Installation Manual | Operating instructions EN | 3-6 Viewing pictures The unit has two monitor outputs, A and B. The way in which these monitors display pictures depends on how the system has been set up. Viewing Monitor A The drawing shows all possible views for monitor A. Some multiscreen views may have been disabled during set-up. The Divar model and the number of connected cameras can also influence the multiscreen views available. Monitor A is the main monitor.
Divar | Installation Manual | Operating instructions EN | 3-7 Multiscreen Cameo assignment To view different multiscreen displays on monitor A: Assigning cameras to cameos in a multiscreen view: 1. Press the multiscreen key 1. Press the ALT key . > A multiscreen display of camera pictures appears on monitor A. 2. Press the multiscreen key multiscreen view. again to go to the next programmed > If you continue to press the multiscreen key enabled multiscreen views.
Divar | Installation Manual | Operating instructions Zoom To zoom in on a camera picture: 1. Press the ALT key . > The ALT indicator lights. 2. Press the zoom key . > The zoom indicator lights. > The picture is enlarged by a factor of 2. 3. Use the arrow keys to select the area of the picture to be displayed. 4. Press the zoom key again to zoom in further. > The picture is enlarged by a factor of 4. 5. Use the arrow keys to select the area of the picture you want to see. 6.
Divar | Installation Manual | Operating instructions EN | 3-9 Live, playback and search modes Live mode Playback mode The live mode is the normal operating mode of the unit where you watch live pictures from the cameras. From the live mode you can switch to the search mode, the playback mode or to the system menu. In playback mode the video control keys operate as follows: Access to search and playback functions may require a password. Discuss this with your administrator.
Divar | Installation Manual | Operating instructions Protecting or archiving a video recording 1. Press the pause key for longer than one second during playback to mark the beginning of a video segment for protection or archiving. > A dialog window appears. > The time and date of the marker at which the video segment starts is shown. 2. Press the select key archive. to continue playing the video you wish to protect or 3. During playback, press the pause key mark the end of the video segment.
Divar | Installation Manual | Operating instructions • • • • • • • • • • • • Fill in a time and date from which to start the search. Fill in an end time and date to limit the time span of the search. If ATM/POS is selected, fill in the text string (16 characters maximum) you wish to search for. This text string is case insensitive. Select Start Search (or press F2) to initiate the search procedure.
Divar | Installation Manual | Operating instructions EN | 3-12 Triggers and alarms Various types of events can change the way the unit works. These events can be: Background events • • • • Triggers and alarms can change background tasks that you, as user, may not even notice. Unit responses that are not visible to the user are, for example, a change in recording speed, the activation of the output relay and event logging.
Divar | Installation Manual | Operating instructions EN | 3-13 Alarm inputs Motion alarm If an input causes an alarm If a motion detection signal causes an alarm • Monitors A and B can switch to a pre-programmed view mode. • Monitor A: The border around the displayed cameos is red. The alarm icon • Monitors A and B can switch to a pre-programmed view mode. • Monitor A: The border around the displayed cameos is yellow. The motion is displayed in each cameo. An alarm status message is displayed.
Divar | Installation Manual | Operating instructions EN | 3-14 Video loss alarm Multiple alarms Monitor A switches to multiscreen view if more than one alarm occurs. The If the loss of a video signal causes an alarm: latest alarm status message is always shown. Pressing the acknowledge key deactivates all alarms. Monitor A or B can be set up to show the video loss signal. • Monitor A switches to multiscreen view. The lost camera signal is displayed as a black cameo with the video loss message.
Divar | Installation Manual | Hardware setup EN | 4-1 CHAPTER 4 Hardware setup This chapter contains detailed information about the connection of external equipment to the unit. The connector types and their pin signals are described. All the connectors are located at the rear panel of the unit.
Divar | Installation Manual | Hardware setup Rack mounting The Divar can be mounted in a 19-inch rack. A rack mounting kit is supplied with the unit that includes: • left and right rack mount ears • four Torx screws with integrated lock washers. • a Torx screwdriver Mounting 1. Remove the four Torx screws (two on each side) located near the front panel on the right and left side of the housing. 2. Attach the mounting ears to each side ensuring that the lip is under the unit.
Divar | Installation Manual | Hardware setup EN | 4-3 Monitor connections Console port connection Connect the unit to the monitors using 75-ohm video coaxial cables with BNC connectors. The unit provides a 1Vpp CVBS signal. The serial RS232 console port connector is used to connect a PC to the unit for configuration or service purposes. Use a null-modem cable to connect the serial port of the PC to the unit. The Baud rate can be selected in the menu system.
Divar | Installation Manual | Hardware setup EN | 4-4 Keyboard connections The keyboard input and output connectors are used to connect an external keyboard to the unit. Connect the keyboard to the KBD IN connector. Up to 4 external keyboards can be connected when the optional keyboard port expander (LTC2604) is used. For short distances (up to 30m), standard 6-core telecom flat cable can be used to supply power and signal connections for the keyboard.
Divar | Installation Manual | Hardware setup Ethernet connection The standard RJ-45 Ethernet socket is used to connect the unit directly to a PC or to a network. The Ethernet is also used to connect to an ATM/POS bridge unit. To connect directly to a network hub, use a straight-through network cable. To connect directly to a PC, use the supplied cross-over network cable. Consult with your local IT personnel for the specific type of cable needed.
Divar | Installation Manual | Hardware setup EN | 4-6 Specifications Control port The control port is a bi-phase port for connecting the control units of controllable cameras. Five bi-phase outputs are provided for dome camera and pan, tilt and zoom control. The screw terminal connection board supplied with the unit simplifies all bi-phase connections to the unit. 8 1 15 9 Bosch Security Systems 128 Ohm Overvoltage protection: ±30V max. Differential voltage amplitude:1V min, 2V max.
Divar | Installation Manual | Hardware setup EN | 4-7 External I/O connection Connecting the Inputs Alarm inputs and outputs are supplied via a 25-pole D-type socket. The screw terminal input/output connection board supplied with the unit simplifies all alarm connections to the unit. Each (alarm) input line can be switched by a relay contact from devices such as pressure pads, passive infra-red detectors, smoke detectors and similar devices. Wire them as either N/O or N/C.
Divar | Installation Manual | Hardware setup EN | 4-8 Signal name: Pin no. Description SCSI connection Alarm_in_6 6 Alarm input 6 Alarm_in_7 7 Alarm input 7 Alarm_in_8 8 Alarm input 8 Alarm_in_9 9 Alarm input 9 The unit provides a 50-pin high density SCSI-2 port for connection of an external storage system, for example, a LP (DVAD) or a RAID (DVAS) storage array. To use this feature, connect the drive's SCSI cable to the SCSI-2 connector on the rear panel.
Divar | Installation Manual | Hardware setup EN | 4-9 Power Supply Testing Power is supplied to the unit via the IEC-style socket. The unit has no on/off switch for security reasons. This means that the unit is always powered as long as the power cable is connected from the unit to a live power socket. In Live mode, select full-screen display for each camera and check the picture quality. If the quality is poor, check: Specifications: • The BNC connections. • Loop-through terminations.
Divar | Installation Manual | Hardware setup Bosch Security Systems EN | 4-10
Divar | Installation Manual | Menu system EN | 5-1 CHAPTER 5 Menu system You access all the parameters used to set up the unit via the menu system. The large number of parameters available gives you the opportunity to program an extensive functionality. There are two ways of accessing the menu system, via the keys on the front of the unit itself or via the PC-based Configuration Tool application.
Divar | Installation Manual | Menu system EN | 5-2 Overview of the menu system The main menu consists of six menu groups: History. The History menu allows you to trace all events that have occurred on the unit. Disk manager. The Disk Manager menu provides information and functions that relate to the maintenance of the storage system including internal and external hard disks. Time/Date.
Divar | Installation Manual | Menu system EN | 5-3 MAIN MENU The main menu gives access to six major menu groups. Each of these groups has a submenu tree where the values and functions can be selected. • Set Advanced Menus to Yes to see all items; set to No for standard features only.
Divar | Installation Manual | Menu system EN | 5-4 HISTORY > DISK The History menu provides a list of all events that have occurred. This list can be filtered to show only those events you wish to see. The Disk Manager menu gives access to information on the internal hard disk(s) and any external disks connected. The status of the recorded video and associated data is also accessed via this menu. Archiving is accessed via this menu. Access to some menus may be password protected.
Divar | Installation Manual | Menu system >> LOCAL ARCHIVING • Segments of recorded video can be written to (re)writable disks using the local archiving menu. • Select Archive Setup to check the status of the writer, the progress of the writing, or to erase or format rewritable disks. • Select Archive Session to make a list of the video segments to be archived and to start writing.
Divar | Installation Manual | Menu system >> AUTHENTICITY CHECK • This check verifies that video images and associated data have not been modified. • Select the period within which the authenticity check runs. The default values are the same as the earliest and latest available recording times. • Press the escape key to cancel the check. • During the check all other front panel keys are disabled. • If the result is Not OK, the date and time of the tampered video is displayed.
Divar | Installation Manual | Menu system EN | 5-7 TIME/DATE > VIEW SETTINGS > The View Settings menu allows you to set up the display of the individual cameras. You can also set the sequence in which the cameras are displayed and the duration. Use the Configure Monitors submenu to set up the monitor displays.
Divar | Installation Manual | Menu system Adjust contrast • • • Select a camera in the menu or press a camera key on the unit. The selected camera image appears. Vary the manual gain value between -100 and +100 to adjust the contrast. To set the default value (0), press the F1 key. >>> Camera controllable • • • A check mark under a camera number indicates that it can be controlled remotely by the Control Center application. Press a camera key on the unit to make a camera controllable or not.
Divar | Installation Manual | Menu system >>> Multiscreen modes • • • Pressing the multiscreen key on the unit cycles through all enabled multiple view modes. Enable only those views you wish to see when you use the multiscreen key. The multiscreen modes that are available depend on the number of cameras connected and the Divar model. >>> ATM/POS (requires bridge and license) • • • ATM/POS data is viewed on monitor A in full-screen mode only.
Divar | Installation Manual | Menu system EN | 5-10 >>> Disk Full Alarm Setup • • • • Set the percentage of used disk space at which the disk-full warning message is displayed. Set the time in minutes before the disk is full at which a disk-full alarm is generated. Select the number of the output relay that is activated when a diskfull alarm is generated. Enable the beeper to activate it when a disk-full alarm is generated.
Divar | Installation Manual | Menu system EN | 5-11 Auto-protect Display mon B • • • • • • Four inputs can be used to trigger automatic protection of video clips. Select the inputs you want to use for each of these triggers. Set to None if you do not want automatic protection. Select the length of time (1 to 60 minutes) that you want protected before and after the event. These values are valid for all four inputs.
Divar | Installation Manual | Menu system • • The entire history list is erased if you select the Clear History item. Date/time changes of stored video are always logged and cannot be disabled or cleared. >> LOCAL PASSWORDS • Set or change the password that allows access to playback functions. • Set or change the password that allows access to the configuration functions. • Use the camera keys (1 to 9) on the front of the unit to enter a four-digit password in the dialog box that appears.
Divar | Installation Manual | Menu system >>> COM port • • The COM port is an RS232 serial port used mainly for connecting a PC or an alarm panel to the unit. Most parameters are fixed. Select the appropriate baud rate. >>> ATM/POS setup (requires bridge and license) • • The list of all ATM/POS bridges connected to the unit shows the IP address and the connection status. Use the arrow keys to move to a bridge and select it to open a terminal configuration menu for that bridge.
Divar | Installation Manual | Menu system Add schedule • • • • Select the profile name, the begin and end times, and the days on which you want the profile to be active. Only five profiles changes can occur in any one day. Select a number from 0 to 23 for the hour. Select between 0, 15, 30 or 45 for the minutes. If the begin time is later than the end time, then the profile is active from the end time until the begin time on the next day.
Divar | Installation Manual | Menu system >>> Output handling • • • Select the profile for which you wish to configure the output handling. Select the number of the output relays to be activated when an enabled event in the selected profile is activated. Enable the beeper to activate it when an enabled event in the selected profile is activated. EN | 5-15 Input • • • • >>> Recording setup • • Recording behavior for each of the six profiles is specified in three submenus.
Divar | Installation Manual | Menu system Bosch Security Systems EN | 5-16
Divar | Installation Manual | Using the Configuration Tool EN | 6-1 CHAPTER 6 Using the Configuration Tool The Configuration Tool is a software application that makes the installation and configuration of a unit faster and easier. The Configuration Tool runs on a PC that is connected to the Divar either directly via an RS232 serial connection or via an Ethernet network connection.
Divar | Installation Manual | Using the Configuration Tool EN | 6-2 Getting started To use the Configuration Tool to change settings, the unit must be physically connected to a PC via the RS232 Console Port or via a network connection. The Configuration Tool application must be installed on the PC. System requirements Operating platform: A PC or compatible running Windows 95, Windows 98, Windows Millennium, Windows NT 4.0 (SP4), Windows 2000 or Windows XP.
Divar | Installation Manual | Using the Configuration Tool EN | 6-3 How to Log in When you start the Configuration Tool as a stand-alone application via a network, the Login window appears. (Click Cancel to discontinue login and exit the application.) To automatically detect all enabled Divars on the network: 1. Click Detect. > To detect a Divar, Discovery must be enabled on that Divar. 2. Select a Divar and click OK to add the selected Divar to the list.
Divar | Installation Manual | Using the Configuration Tool EN | 6-4 Login Maximum number of users When you start the Configuration tool application, the Login window appears. (Click Cancel to discontinue login and exit the application.) If the maximum number of users for the Control Center is exceeded, a window is displayed. An administrator can use this window to force off a user. The list shows all users that are currently logged in. To disconnect a user: 1. Select a user in the list. 2. Click Yes.
Divar | Installation Manual | Using the Configuration Tool EN | 6-5 Introducing the main window The Configuration Tool window is divided into 3 panes. The buttons in the left pane are always available. Clicking one of these buttons changes the contents of the center pane. The buttons in the right pane are control buttons that give you direct access to various tasks. History button Click the History button to display a list of events in the center pane.
Divar | Installation Manual | Using the Configuration Tool EN | 6-6 Service button Using the control buttons Click the Service button to get a list of diagnostic messages and to access the firmware update function. This function is only available if you are connected to the unit via a serial connection and is password protected. The right side of the main window has several buttons that allow you to perform common tasks quickly: Import / Export Help button Click the Help button appears.
Divar | Installation Manual | Using the Configuration Tool EN | 6-7 Refining settings Save When you select Import, Export or Download a pop-up window allows you to select particular groups of settings. You can select All settings, All settings except or Only to determine how the list is constructed. To refine your selection When the Overview or History page is active, you can save the complete contents of the page or list. click in the list.
Divar | Installation Manual | Using the Configuration Tool Bosch Security Systems EN | 6-8
Divar | Installation Manual | Menu default values EN | 7-1 CHAPTER 7 Menu default values The table on the following pages lists the items of the menu system of the unit with default values. The righthand column of the table gives the default values of these menu items. These values are restored when the Factory defaults item of the System settings menu is selected.
Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 EN | 7-2 Level 4 Level 5 Default value History Time / Date Show alarms Yes Show motions Yes Show network connectivity Yes Show errors Yes Time zone GMT+01:00 Western Europe (PAL) GMT -06:00 Eastern time (NTSC) Time format 24-hour (PAL) 12-hour (NTSC) Date format YYYY-MM-DD Synchronize Use timer server No IP address 0. 0. 0. 0 Daylight saving Yes View Settings Camera setup Camera name Select input 01 . .
Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 EN | 7-3 Level 4 Level 5 Default value Camera control Auto camera contrast On Adjust contrast 0 Camera controllable No cameras selected Bilinx camera enabled All cameras selected for Bilinx version List Fullscreen monitor A All cameras connected List Fullscreen monitor B All cameras connected Dwell time monitor A 5 seconds Dwell time monitor B 5 seconds Display titles monitor A On Display titles monitor B On
Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 EN | 7-4 Level 4 Level 5 Default value System Settings Language English Recording Setup Record mode Continuous Overwrite protection None Pre-event time 10 sec. Disk Full Alarm Setup Disk Full warning 95% Disk Full alarm 1 min.
Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 EN | 7-5 Level 4 Level 5 Default value Protected after event 10 minutes Max. auto-protected 25% of disk On max.
Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 EN | 7-6 Level 4 Level 5 Default value Default gateway 0. 0. 0. 0 HTTP port 80 Bandwidth limit 100 MBPS Network access IP Range List of IP addresses 0. 0. 0. 0 255.255.255.255 List of users User name ADMINISTRATOR, USER2...
Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 EN | 7-7 Level 4 Level 5 Default value Profiles Profile manager Camera pre-position on profile change Camera pre-position None Select profile 1 Inputs enable Enabled for connected cameras Inputs alarm Enabled for connected cameras Motion enable Disable all Motion alarm Disable all Video loss enable Enabled for connected cameras Auto acknowledge alarms Yes Select profile 1 Relay enable Relays 1 and 2 enabled
Divar | Installation Manual | Menu default values Level 1 Level 2 Level 3 EN | 7-8 Level 4 Level 5 Default value Motion Cameras not in alarm IPS No change Recording duration 15 seconds Access restrictions Select profile 1 Local playback password Disable User 2 Access User 3 Access User 4 Access User 5 Access User 6 Access Copy from None Copy to None Copy system behavior Advanced menus Bosch Security Systems No
Divar | Installation Manual | Technical specifications EN | 8-1 CHAPTER 8 Technical specifications The following pages give the technical specifications of the unit.
Divar | Installation Manual | Technical specifications EN | 8-2 Electrical overvoltage protection ±40V, max. cable length 1.5km Bilinx: Voltage and Power All models Bilinx-enabled controllable cameras via BNC camera connectors (Divar Bilinx version only). 100-240 VAC; 0.7-0.3A, 50/60Hz Connectors Video Video inputs: 6, 9 or 16 looping BNC, auto-terminating Video standard: PAL/NTSC auto-detect Ethernet: RJ45 shielded, 10/100 BaseT according IEEE802.
Divar | Installation Manual | Technical specifications DVD writer Write speeds: Divar write speed: EN | 8-3 Electromagnetic Compatibility DVD+R / DVD+RW: 4x (or higher) EMC requirements: USA:FCC Part 15, Class B CD-R: 40x (or higher) EU: EMC directive 89/336/EEC CD-RW: 24x (or higher) Immunity:EN50130-4 1MB/sec. approx.
Divar | Installation Manual | Technical specifications Bosch Security Systems EN | 8-4
Bosch Sicherheitssysteme GmbH Bosch Security Systems B.V. Ludwig-Bölkow-Allee P.O. Box 80002 85521 Ottobrunn 5600 JB Eindhoven Germany The Netherlands www.bosch-sicherheitssysteme.de www.boschsecuritysystems.com © 2005 Bosch Security Systems B.V. Subject to change. Printed in Portugal.