-13-
Issue
Remedy
Problem
temperature
indicator
d;
measurement
not
possible.
The measuring tool is not within the operating
temperature of – 10 °C to +50 °C (+14 °F to +122
°F), in the continuous measurement function to +40
°C (+104 °F).
Wait until the measuring tool has reached the
operating temperature
Battery
indication
c
is
indicated
Battery voltage decreasing (measurement still
possible)
Replace batteries
Battery
indication
c
flashes,
measurement
not
possible
Battery voltage too low
Replace batteries
The
indications
“Err.”
and
“-
-
-”
are
indicated
in
the
display
The angle between the laser beam and the
target is too acute.
Enlarge the angle between the laser beam
and the target
The target surface reflects too intensely (e.g.
a mirror) or insufficiently (e.g. black fabric), or
the ambient light is too bright
Work with the laser target plate
21
(optional
accessory)
The laser beam outlet
17
or the reception lens
18
are misted up (e.g. due to a rapid
temperature change).
Wipe the laser beam outlet
17
and/or the
reception lens
18
dry using a soft cloth
The calculated area or volume value is larger
2 3
than 99990 ft
or
ft
.
Change unit of measure to “m”
The
indication
“Err.”
flashes
at
the
top
in
the
display
Addition/Subtraction of different types of
measurements
Only add/subtract of the same type
Unreliable
measuring
result
The target surface does not reflect correctly
(e.g. water, glass).
Cover off the target surface
The laser beam outlet
17
or the reception lens
18
are covered.
Make sure that the laser beam outlet
17
or the
reception lens
18
are unobstructed
Measuring
result
not
plausible
Wrong r eference point set
Select reference point that corresponds to
measurement
Obstruction in path of laser beam
Laser point must be completely on target
surface