Quick Guide
3
Residential
and Small Commercial
Blue Line Gen 2 Series
PIR TriTech® (PIR+MW)
Standard Pet Friendly® Quad Standard Pet Friendly®
Commercial Type Number
ISC–BPR2–W12 ISC–BPR2–WP12 ISC–BPQ2–W12 ISC–BDL2–W12x ISC–BDL2–WP12x ISC–BDL2–WP6x
Overview Application risk level Low to moderate risk Low to moderate risk Moderate risk Low to Moderate risk Low to Moderate risk Low to Moderate risk
Environment * Standard Standard Difficult Difficult Difficult Difficult
Specifications Coverage/range 40 x 40 ft (12 x 12 m) 40 x 40 ft (12 x 12 m) 40 x 40 ft (12 x 12 m) 40 x 40 ft (12 x 12 m) 40 x 40 ft (12 x 12 m) 20 x 20 ft (6 x 6 m)
Mounting height
7.5 to 9 ft
(2.3 to 2.75 m)
7.5 to 9 ft
(2.3 to 2.75 m)
7.5 to 9 ft
(2.3 to 2.75 m)
7.5 to 9 ft
(2.3 to 2.75 m)
7.5 to 9 ft
(2.3 to 2.75 m)
7.5 to 9 ft
(2.3 to 2.75 m)
Operating temperature **
–20° to 130°F
(–30° to 55°C)
–20° to 130°F
(–30° to 55°C)
–20° to 130°F
(–30° to 55°C)
–20° to 130°F
(–30° to 55°C)
–20° to 130°F
(–30° to 55°C)
–20° to 130°F
(–30° to 55°C)
Operating voltage
9–15 VDC 9–15 VDC 9–15 VDC 9–15 VDC 9–15 VDC 9–15 VDC
Current draw (typical)
10 mA 10 mA 10 mA 10 mA 10 mA 10 mA
Features First Step Processing
∎ ∎ ∎ ∎ ∎ ∎
Microwave noise adaptive processing
– – – ∎ ∎ ∎
Dynamic temperature compensation
∎ ∎ ∎ ∎ ∎ ∎
Wall-to-wall coverage
∎ ∎ ∎ ∎ ∎ ∎
Look-down zone
∎ ∎ ∎ ∎ ∎ ∎
Pet/small animal immunity
10 lb (4.5 kg) 45 lb (20 kg) 10 lb (4.5 kg) 10 lb (4.5 kg) 100 lb (45 kg) 100 lb (45 kg)
Alarm output
NC NC NC NC NC NC
Alarm memory
– – – – – –
Anti-mask
– – – – – –
Tamper
Cover Cover Cover Cover Cover Cover
Sealed optical chamber
∎ ∎ ∎ ∎ ∎ ∎
Ease of installation *** No-adjust installation
∎ ∎ ∎ ∎ ∎ ∎
Enable/disable LED
∎ ∎ ∎ ∎ ∎ ∎
Enable/disable pet immunity
– ∎ – – ∎ ∎
Enable/disable look-down
∎ ∎ ∎ – – –
Microwave Doppler range adjustment
– – – ∎ ∎ ∎
Remote walk test
– – – – – –
Remote self test
– – – – – –
Certifications AFNOR, CCC, CE,
EN50131–2–2 Grade 2,
INCERT, UL
AFNOR, CCC, CE,
EN50131–2–2 Grade 2,
INCERT, UL
AFNOR, CCC, CE,
EN50131–2–2 Grade 2,
INCERT, UL
AFNOR, CCC, CE,
EN50131–2–4 Grade 2,
FCC, IC, INCERT, UL
AFNOR, CCC, CE,
EN50131–2–4 Grade 2,
FCC, IC, INCERT, UL
AFNOR, CCC, CE,
EN50131–2–4 Grade 2,
FCC, IC, INCERT, UL
* Difficult environments include rooms with potential false alarm sources, such as: air conditioning vents, strong drafts of cold or warm air, slow moving objects such
as curtains, plants, or signs hanging from the ceiling, a fan that could be running when the system is activated, under floor heating, room temperatures exceeding 86°F
(30°C), a detector that could be exposed to bright white light (car headlights, floodlights, direct sunlight, etc.)
** For UL installations the operating range is 32° to 120°F (0° to 49°C), indoor use.
*** All models feature a two-piece design, self-locking enclosure, interchangeable mounting base, integrated bubble level, and removable lift-gate terminal strips.
∎ Available – Not available