Small to Medium Commercial
Commercial Series
TriTech® (PIR+MW)
Standard Anti-mask
Commercial Type Number
ISC–CDL1–W15x ISC–CDL1–WA15x ISC–CDL1–WA12x
Overview Application risk level Moderate risk High risk High risk
Environment * Difficult Difficult Difficult
Specifications Coverage/range
50 x 50 ft
(15 x 15 m)
50 x 50 ft
(15 x 15 m)
40 x 40 ft
(12 x 12 m)
Mounting height 7.5 to 9 ft
(2.3 to 2.75 m)
7.5 to 9 ft
(2.3 to 2.75 m)
7.5 to 9 ft
(2.3 to 2.75 m)
Operating temperature **
–22° to 130°F
(–30° to 55°C)
–22° to 130°F
(–30° to 55°C)
–22° to 130°F
(–30° to 55°C)
Operating voltage
9–15 VDC 9–15 VDC 9–15 VDC
Current draw (typical)
10 mA 15 mA 15 mA
Features First step processing
∎ ∎ ∎
Microwave noise adaptive processing
∎ ∎ ∎
Range adaptive radar
– – –
Active white light suppression
∎ ∎ ∎
Dynamic temperature compensation
∎ ∎ ∎
Look-down zone
∎ ∎ ∎
Pet/small animal immunity
10 lb (4.5 kg) 10 lb (4.5 kg) 10 lb (4.5 kg)
Alarm output
NC NC NC
Alarm memory
∎ ∎ ∎
Anti-mask
– ∎ ∎
Tamper
Cover Cover + wall Cover + wall
Sealed optical chamber
∎ ∎ ∎
Ease of installation *** No-adjust installation
∎ ∎ ∎
Enable/disable look-down
∎ ∎ ∎
Enable/disable LED
∎ ∎ ∎
Microwave Doppler range adjustment
∎ ∎ ∎
Remote walk test
– – –
Remote self test
– – –
Certifications AFNOR, CCC, CE, EN50131–2–4 Grade 2,
FCC, IC, INCERT, UL
AFNOR, CCC, CE, EN50131–2–4 Grade 3,
FCC, IC, INCERT, UL
AFNOR, CCC, CE, EN50131–2–4 Grade 3,
FCC, IC, INCERT, UL
* Difficult environments include rooms with potential false alarm sources, such as: air conditioning vents, strong drafts of cold or warm air, slow moving objects such as
curtains, plants, or signs hanging from the ceiling, a fan
that could be running when the system is activated, under floor heating, room temperatures exceeding 86°F (30°C), a detector that could be exposed to bright white
light (car headlights, floodlights, direct sunlight, etc.)
** For UL installations the operating range is 32° to 120°F (0° to 49°C), indoor use.
*** All models feature a two-piece design, self-locking enclosure, interchangeable mounting base, integrated bubble level, and removable lift-gate terminal strips.
∎ Available – Not available