Quick Guide
6
Premises Wireless†
RADION
PIR TriTech® (PIR+MW)
Standard Curtain Standard
Commercial Type Number
RFPR–12 RFPR–C12 RFDL–11
Overview Application risk level
Low to moderate risk Low to moderate risk Low to Moderate risk
Environment *
Standard Standard Difficult
Specifications Frequency
433.42 MHz 433.42 MHz 433.42 MHz
Coverage/range
40 x 40 ft (12 x 12 m) 40 x 5 ft (12 x 1.5 m) 35 x 35 ft (11 x 11 m)
Mounting height
7 to 9 ft (2.1 to 2.75 m) 7 to 8.5 ft (2.1 to 2.6 m) 6.5 to 8 ft (2.0 to 2.4 m)
Operating temperature **
32° to 120°F (0° to 49°C) 32° to 120°F (0° to 49°C) 32° to 120°F (0° to 49°C)
Operating voltage
3 VDC 3 VDC 6 VDC
Power source
One CR123A Lithium Battery One CR123A Lithium Battery Four AA Alkaline Batteries
Battery life
Up to 5 years Up to 5 years Up to 5 years
Features Motion Analyzer II signal processing
∎ ∎ ∎
Microwave noise adaptive processing
– – ∎
Dynamic temperature compensation
∎ ∎ ∎
Wall-to-wall coverage
∎ ∎ ∎
Look-down zone
∎ ∎ ∎
Pet/small animal immunity
30 lb (13 kg) 30 lb (13 kg) 100 lb (45 kg)
Anti-mask
– – –
Tamper
Cover + wall Cover + wall Cover + wall
Sealed optical chamber
∎ ∎ ∎
Ease of installation *** No-adjust installation
∎ ∎ –
Enable/disable LED
– – –
Enable/disable pet immunity
– – ∎
Enable/disable look-down
∎ ∎ –
Switchable detection patterns
– – –
Microwave Doppler range adjustment
– – ∎
Certificates
AFNOR, CCC, CE, EN50131–2–2 Grade 2,
FCC, IC, INCERT, UL
AFNOR, CCC, CE, EN50131–2–2 Grade 2,
FCC, IC, INCERT, UL
AFNOR, CCC, CE, EN50131–2–2 Grade 2,
FCC, IC, INCERT, UL
* Difficult environments include rooms with potential false alarm sources, such as: air conditioning vents, strong drafts of cold or warm air, slow moving objects such as curtains, plants, or signs hanging from the ceiling, a fan
that could be running when the system is activated, under floor heating, room temperatures exceeding 86°F (30°C), a detector that could be exposed to bright white light (car headlights, floodlights, direct sunlight, etc.)
** For UL installations the operating range is 32° to 120°F (0° to 49°C), indoor use.
*** All models feature a two-piece design, self-locking enclosure, interchangeable mounting base, integrated bubble level, and removable lift-gate terminal strips.
† Wireless peripherals require a compatible receiver. B810 RADION receiver is compatible with SDI2 bus panels (B Series and G Series); RFRC–OPT is compatible with Option bus panels; RFRC–STR is compatible with
Streamline bus panels.
∎ Available – Not available