Quick Guide

8
Premises Wireless (ZigBee)
RADION ZB
PIR TriTech® (PIR+MW)
Standard Standard
Commercial Type Number
RFPR-ZB RFDL-ZB
Overview Application risk level Low to moderate risk Low to Moderate risk
Environment * Standard Difficult
Specifications Frequency
2.4 GHz 2.4 GHz
Features Coverage/range 40 x 40 ft (12 x 12 m) 40 x 40 ft (12 x 12 m)
Mounting height
7.5 to 9 ft (2.3 to 2.7 m) 7.5 to 9 ft (2.3 to 2.7 m)
Operating temperature **
32° to 120°F (0° to 49°C) 32° to 120°F (0° to 49°C)
Operating voltage
3 VDC 3 VDC
Power source ***
One CR123A Lithium Battery One CR123A Lithium Battery
Battery life ***
Up to 6 years Up to 3 years
First Step Processing
Microwave noise adaptive processing
Dynamic temperature compensation
Wall-to-wall coverage
Look-down zone
Pet/small animal immunity
45 lb (20 kg) 100 lb (45 kg)
Anti-mask
Tamper
Cover + wall Cover + wall
Sealed optical chamber
Ease of installation**** No-adjust installation
Enable/disable LED
Enable/disable pet immunity
Enable/disable look-down
Microwave Doppler range adjustment
Certificates
FCC, IC, cETLus, ZigBee, iControl FCC, IC, cETLus, ZigBee, iControl
* Difficult environments include rooms with potential false alarm sources, such as: air conditioning vents, strong drafts of cold or warm air, slow moving objects such as curtains, plants, or signs hanging from the ceiling, a fan
that could be running when the system is activated, under floor heating, room temperatures exceeding 86°F (30°C), a detector that could be exposed to bright white light (car headlights, floodlights, direct sunlight, etc.)
** For UL installations the operating range is 32° to 120°F (0° to 49°C), indoor use.
*** Power source has capacity for an additional battery increasing the battery life from 6 to 10 years (RFPR-ZB) or from 3 to 6 years (RFDL-ZB).
**** All models feature a two-piece design, self-locking enclosure, interchangeable mounting base, integrated bubble level, and removable lift-gate terminal strips.
∎ Available – Not available