Quick Guide
5
Large Commercial
and High Security
Professional Series
PIR TriTech® (PIR+MW)
Standard Anti-mask Standard Anti-mask Curtain Anti-mask Curtain
Commercial Type Number
ISC–PPR1–W16 ISC–PPR1–WA16x ISC–PDL1–W18x ISC–PDL1–WA18x ISC–PDL1–WC30x ISC–PDL1–WAC30x
Overview Application risk level Moderate risk High risk Moderate risk High risk Moderate risk High risk
Environment * Standard Standard Difficult Difficult Difficult Difficult
Specifications Optics 86 Zone 86 Zone 86 Zone 86 Zone Fresnel curtain Fresnel curtain
Coverage/range 50 x 70 ft
(15 x 21 m)
25 x 32 ft
(7 x 10 m)
50 x 70 ft
(15 x 21 m)
25 x 32 ft
(7 x 10 m)
60 x 80 ft
(18 x 24 m)
25 x 32 ft
(7 x 10 m)
60 x 80 ft
(18 x 24 m)
25 x 32 ft
(7 x 10 m)
100 x 10 ft
(30 x 3 m)
100 x 10 ft
(30 x 3 m)
Mounting height 7 to 10 ft
(2.2 to 3 m)
7 to 10 ft
(2.2 to 3 m)
7 to 10 ft
(2.2 to 3 m)
7 to 10 ft
(2.2 to 3 m)
7 to 10 ft
(2.2 to 3 m)
7 to 10 ft
(2.2 to 3 m)
Operating temperature **
–20° to 130°F
(–29° to 55°C)
–20° to 130°F
(–29° to 55°C)
–20° to 130°F
(–29° to 55°C)
–20° to 130°F
(–29° to 55°C)
–20° to 130°F
(–29° to 55°C)
–20° to 130°F
(–29° to 55°C)
Operating voltage
9–15 VDC 9–15 VDC 9–15 VDC 9–15 VDC 9–15 VDC 9–15 VDC
Current draw (typical)
10 mA 18 mA 13 mA 18 mA 18 mA 18 mA
Features Sensor data fusion
∎ ∎ ∎ ∎ ∎ ∎
Microwave noise adaptive processing
– – ∎ ∎ ∎ ∎
Range adaptive radar
– – ∎ ∎ ∎ ∎
Active white light suppression
∎ ∎ ∎ ∎ ∎ ∎
Dynamic temperature compensation
∎ ∎ ∎ ∎ ∎ ∎
Look-down zone
∎ ∎ ∎ ∎ ∎ ∎
Pet/small animal immunity
10 lb (4.5 kg) 10 lb (4.5 kg) 10 lb (4.5 kg) 10 lb (4.5 kg) 10 lb (4.5 kg) 10 lb (4.5 kg)
Alarm output/memory
∎/∎ ∎/∎ ∎/∎ ∎/∎ ∎/∎ ∎/∎
Anti-mask
– ∎ ∎ (MW only) ∎ – ∎
Tamper
∎ ∎ ∎ ∎ ∎ ∎
Sealed optical chamber
∎ ∎ ∎ ∎ ∎ ∎
Ease of installation *** No-adjust installation
∎ ∎ ∎ ∎ ∎ ∎
Enable/disable look-down
∎ ∎ ∎ ∎ ∎ ∎
Switchable coverage patterns
∎ ∎ ∎ ∎ – –
Microwave Doppler range adjustment
– – ∎ ∎ ∎ ∎
Remote walk test
∎ ∎ ∎ ∎ ∎ ∎
Remote self test
∎ ∎ ∎ ∎ ∎ ∎
Certifications AFNOR, CCC, CE,
EN50131–2–2 Grade 2,
FCC, IC, INCERT, UL
AFNOR, CE,
EN50131–2–2 Grade 3,
FCC, IC, INCERT, UL
AFNOR, CCC, CE,
EN50131–2–4 Grade 2,
FCC, IC, INCERT, UL
AFNOR, CCC, CE,
EN50131–2–4 Grade 2,
FCC, IC, INCERT, UL
AFNOR, CE,
EN50131–2–4 Grade 2,
FCC, IC, INCERT, UL
AFNOR, CE,
EN50131–2–4–Grade 3
* Difficult environments include rooms with potential false alarm sources, such as: air conditioning vents, strong drafts of cold or warm air, slow moving objects such as curtains, plants, or signs hanging from the ceiling, a fan
that could be running when the system is activated, under floor heating, room temperatures exceeding 86°F (30°C), a detector that could be exposed to bright white light (car headlights, floodlights, direct sunlight, etc.)
** For UL installations the operating range is 32° to 120°F (0° to 49°C), indoor use.
*** All models feature a two-piece design, self-locking enclosure, interchangeable mounting base, integrated bubble level, and removable lift-gate terminal strips.
∎ Available – Not available