Quick Guide
6
Premises Wireless†
RADION
PIR TriTech® (PIR+MW)
Standard Curtain Standard
Commercial Type Number
RFPR–12 RFPR–C12 RFDL–11
Overview Application risk level
Low to moderate risk Low to moderate risk Low to Moderate risk
Environment *
Standard Standard Standard
Specifications Frequency
433.42 MHz 433.42 MHz 433.42 MHz
Coverage/range
40 x 40 ft (12 x 12 m) 40 x 5 ft (12 x 1.5 m) 35 x 35 ft (11 x 11 m)
Mounting height
7 to 9 ft (2.1 to 2.75 m) 7 to 8.5 ft (2.1 to 2.6 m) 6.5 to 8 ft (2.0 to 2.4 m)
Operating temperature **
32° to 120°F (0° to 49°C) 32° to 120°F (0° to 49°C) 32° to 120°F (0° to 49°C)
Operating voltage
3 VDC 3 VDC 6 VDC
Power source
One CR123A Lithium Battery One CR123A Lithium Battery Four AA Alkaline Batteries
Battery life
Up to 5 years Up to 5 years Up to 5 years
Features First step processing
∎ ∎ ∎
Motion Analyzer II signal processing
∎ ∎ ∎
Microwave noise adaptive processing
– – ∎
Dynamic temperature compensation
∎ ∎ ∎
Wall-to-wall coverage
∎ ∎ ∎
Look-down zone
∎ ∎ ∎
Pet/small animal immunity
30 lb (13 kg) 30 lb (13 kg) 100 lb (45 kg)
Alarm output/memory
–/– –/– –/–
Anti-mask
– – –
Tamper
∎ ∎ ∎
Sealed optical chamber
∎ ∎ ∎
Ease of installation *** No-adjust installation
∎ ∎ –
Enable/disable LED
– – ∎
Enable/disable pet immunity
– – ∎
Enable/disable look-down
∎ ∎ –
Switchable detection patterns
– – –
Microwave Doppler range adjustment
– – ∎
Remote walk test
– – –
Remote self test
– – –
Certificates
CCC, CE, EN50131–2–2 Grade 2,
FCC, IC, INCERT, UL
CCC, CE, EN50131–2–2 Grade 2,
FCC, IC, INCERT, UL
CCC, CE, EN50131–2–2 Grade 4,
FCC, IC, INCERT, UL
* Difficult environments include rooms with potential false alarm sources, such as: air conditioning vents, strong drafts of cold or warm air, slow moving objects such as curtains, plants, or signs hanging from the ceiling, a fan
that could be running when the system is activated, under floor heating, room temperatures exceeding 86°F (30°C), a detector that could be exposed to bright white light (car headlights, floodlights, direct sunlight, etc.)
** For UL installations the operating range is 32° to 120°F (0° to 49°C), indoor use.