Operation Manual

DIGISTAT
PRE-PROGRAMMED SETTINGS
The Digistat Programmer
This is a 24-Hour programmable thermostat
product (the same program for every day of the
week) which allows you to set up to 6 time and
temperature events per day.
Pre-set Program 1
The following default settings are pre-programmed
for your convenience:
Every day
Event 1 2 3 4 5 6
Time 06:30 08:30 12:00 14:00 16:30 22:30
Temp. 20 16 16 16 21 7
As shown, at 06:30 , the heating will come on to
raise the temperature to 20°C. At 08:30, the tem-
perature set point is dropped from 20°C down
to16°C, it stays at 16°C throughout the day, until
16:30 when the temperature increases to 21°C.
The temperature then drops down to a night-set-
back temperature of 7°C until 06:30 when the
cycle repeats for the next day.
To switch the thermostat OFF:
Press the + and – simultaneously for 5 seconds
until the OFF is displayed.
The thermostat and heating system will now be
OFF unless the temperature in the controlled
space falls below 7°C, the frost protection set
point.
Please note this does not affect the operation of
the domestic hot water where provided.
To switch ON the thermostat, press any key to
return to auto mode.
5 sec
OPERATING & INSTALLATION
INSTRUCTIONS
4
DT10RF PROGRAMMER
INSTRUCTION MANUAL
8 716 115 493a (02.2009)
8_716_115_493a 9/2/09 09:45 Page 8