DIVAR AN 3000 / DIVAR AN 5000 Digital Video Recorder en Quick Reference Guide
DIVAR AN 3000 / DIVAR AN 5000 Table of Contents | en 3 Table of contents 1 Basic Safety 4 1.1 Safety precautions 4 1.2 Important safety instructions 4 1.3 Important Notices 6 1.4 FCC and UL 8 2 System overview 3 Quick install 10 3.1 Connections 10 3.1.1 Primary connections 12 3.1.2 Optional connections 12 3.2 Powering up 13 3.3 Login 14 3.4 Startup Wizard 15 3.4.1 Reset startup wizard 16 3.4.2 General 16 3.4.3 Encoder 17 3.4.4 Schedule 18 3.4.
en | Basic Safety 1 DIVAR AN 3000 / DIVAR AN 5000 Basic Safety This safety section describes safety requirements and the format used for warnings and cautions. 1.1 Safety precautions Warnings and caution formats Danger! High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death. Warning! ! Medium risk: Indicates a potentially hazardous situation.
Basic Safety | en DIVAR AN 3000 / DIVAR AN 5000 6. 5 Lightning - For added protection during a lightning storm, or when leaving this unit unattended and unused for long periods, unplug the unit from the wall outlet and disconnect the cable system. This will prevent damage to the unit from lightning and power line surges. 7. Controls adjustment - Adjust only those controls specified in the operating instructions. Improper adjustment of other controls may cause damage to the unit.
en | Basic Safety 1.3 DIVAR AN 3000 / DIVAR AN 5000 Important Notices Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit may fall, causing serious injury and/or serious damage to the unit. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer. When a cart is used, use caution and care when moving the cart/apparatus combination to avoid injury from tip-over.
DIVAR AN 3000 / DIVAR AN 5000 Basic Safety | en 7 Caution! ! Electronic Surveillance - This device is intended for use in public areas only. U.S. federal law strictly prohibits surreptitious recording of oral communications. Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precautions to avoid electrostatic discharge. NOTE: Wear required grounded wrist straps and observe proper ESD safety precautions when handling the electrostatic-sensitive printed circuit boards.
en | Basic Safety DIVAR AN 3000 / DIVAR AN 5000 Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information. 1.4 FCC and UL FCC & ICES Information (U.S.A.
DIVAR AN 3000 / DIVAR AN 5000 2 System overview | en 9 System overview The Bosch Video Recorder DIVAR 3000/5000 is a multi-channel digital recorder that uses the latest 960H high resolution technology, plus modern compression techniques. Simultaneous monitoring, recording, archiving and playback are guided remote or local by simple menu selections and operator commands. If required, a variety of optional storage capacities can be added (including built-in HDDs and/or a DVD writer).
3 en | Quick install DIVAR AN 3000 / DIVAR AN 5000 Quick install To get the unit operational, perform the following quick install steps: 1. Make all the hardware connections – see Connections, page 10. 2. Power up the system – see Powering up, page 13. 3. Log in – see Login, page 14. 4. Correctly configure your system software with the Startup wizard (this appears the first time the unit is started) – see Startup Wizard, page 15.
Quick install | en DIVAR AN 3000 / DIVAR AN 5000 11 Connections on back of DIVAR 5000 (16-channel) 2 ON 6 4 8 10 12 14 16 CVBS MON. A 2 4 5 6 7 8 AUDIO OUT 9 10 11 12 13 14 15 16 1 1 3 5 7 9 11 13 15 CVBS MON. B 3 G +12V CTRL C5 NO5 ALARM OUT +12V NO2 C2 C3 NO4 C4 NO3 NO1 C1 0 VIDEO IN OFF ALARM IN G + _ G + _ G RS-485 KEYBOARD MIC IN AUDIO IN RS-232 VIDEO OUT VGA MON.A HDMI MON.
en | Quick install DIVAR AN 3000 / DIVAR AN 5000 Connections on back of DIVAR 5000 (4/8-channel) 1 3 2 4 5 6 7 CVBS MON. A 8 2 4 5 6 7 8 AUDIO OUT VIDEO OUT 1 1 2 3 4 5 6 7 8 CVBS MON. B 3 G +12V CTRL NO5 C5 +12V NO2 C2 0 C3 NO4 C4 VIDEO IN NO3 OFF NO1 C1 ON ALARM IN + _ G ALARM OUT G + _ G RS-485 KEYBOARD MIC IN AUDIO IN RS-232 VGA MON.A HDMI MON.
DIVAR AN 3000 / DIVAR AN 5000 Quick install | en 6. Connect up to 6 ALARM OUT outputs (via the supplied terminal blocks). 7. Connect a pan/tilt/zoom control unit to the RS-485 or RS-232 port. 8. Connect to your network via the ETHERNET connector. 9. Connect extra video out cables to the VIDEO OUT ports if loop through is required to 13 other devices (only for DIVAR 5000). 10.
3.3 en | Quick install DIVAR AN 3000 / DIVAR AN 5000 Login The system login interface is shown in the following figure: Figure 3.1: Login When you startup the system for the first time, the Startup Wizard appears where you can setup the system software. Here the default User ID is ADMINISTRATOR and the default password is 000000 (six zeros). Use the supplied USB mouse, front panel, remote control or keyboard (only on DIVAR 5000) to input data and commands.
DIVAR AN 3000 / DIVAR AN 5000 3.4 Quick install | en 15 Startup Wizard The Startup Wizard opens automatically after you log in for the first time. See following screen: Figure 3.2: Startup wizard first screen Select a language and video standard from the drop-down menus and click . The wizard will guide you through the following steps: 1. Choose to reset the startup wizard to run after the next system restart – see Reset startup wizard, page 16. 2.
en | Quick install 3.4.1 DIVAR AN 3000 / DIVAR AN 5000 Reset startup wizard Figure 3.3: Startup wizard reset If required, select the check box here to activate the Startup wizard after the next system restart (this is only useful if you need to reconfigure the system during the next startup). Later, during operation, you can also reset this mode in the General screen. Click for the next Startup wizard screen (General settings). 3.4.2 General Figure 3.
DIVAR AN 3000 / DIVAR AN 5000 – Quick install | en 17 If changes are required, use the drop-down menus and entry fields to assign the correct settings (if you change the system time and/or date, click before continuing). – 3.4.3 When ready, click to move to the Encoder Startup wizard screen. Encoder Figure 3.5: Startup encode Assign here the encoder settings and click for the next Startup wizard screen (Schedule settings).
en | Quick install 3.4.4 DIVAR AN 3000 / DIVAR AN 5000 Schedule Figure 3.6: Startup schedule Assign here all the schedule settings and click for the next Startup wizard screen (Record settings). Use to copy settings from one channel to other(s). 3.4.5 Record Figure 3.
DIVAR AN 3000 / DIVAR AN 5000 3.4.6 Quick install | en 19 Network Figure 3.8: Startup network Assign here all the network settings and click to complete the Startup wizard (you will need to confirm the setup by clicking ). The system will automatically display the active view mode (with a maximum 16 camera views). From here you can operate your system using the mouse, remote control or front panel. See the following sections.
3.5 en | Quick install DIVAR AN 3000 / DIVAR AN 5000 Shutdown/Logout 1. Right-click the mouse to access the Quick menu; from here choose the option Main menu. 2. Select on the main menu for the Shutdown dialog box. 3. Choose Logout user from the drop-down options. 4. Click . Other options on the drop-down menu are: – Shutdown – Restart system – Switch user. Logout with power button Another way to stop all operations is: 1.
DIVAR AN 3000 / DIVAR AN 5000 4 First time operation | en 21 First time operation Once the Startup Wizard steps have been completed, your monitor will show the normal live mode with real time camera displays ready to operate your system. From here, you can control your system via menus (Quick menu and Main menu) using the mouse, front panel buttons or the remote control. Notice! The mouse is normally the preferred input device when setting up the system and entering field values.
en | First time operation – DIVAR AN 3000 / DIVAR AN 5000 To modify the channel ID, see display settings (Main Menu > Setting > Display).
First time operation | en DIVAR AN 3000 / DIVAR AN 5000 Icon name Function Realtime Press to playback the previous 5-60 minutes recorded on the playback current channel (default is 5 minutes): 23 The playback screen supports drag and play function - use your mouse to drag the play bar to any playback start time. Use the pause and exit functions as required.
4.2 en | First time operation DIVAR AN 3000 / DIVAR AN 5000 Quick menu When in normal view mode, right-click the mouse for the following quick menu: Figure 4.
DIVAR AN 3000 / DIVAR AN 5000 4.
en | First time operation Right button DIVAR AN 3000 / DIVAR AN 5000 In Live mode, the following quick menu appears: If you are currently in a menu, right-click to exit the current menu without saving any modifications. 2013.11 | 1.
DIVAR AN 3000 / DIVAR AN 5000 4.4 First time operation | en 27 Main menu Access the Main menu as follows: – Use the Enter key and the direction buttons on the front panel or the remote control – Right-click the mouse for the Quick menu and select ‘Main menu’ The Main menu has six menu selections, each with further submenus. See following figure. Figure 4.
4.5 en | First time operation DIVAR AN 3000 / DIVAR AN 5000 Search/Playback Click Search/Play in the Main Menu (or from the Quick menu) for the following interface. See following figure Figure 4.5: Search/Play screen ID Name Function 1 Display Display of the currently chosen picture or file (supports 1/4/9/16-window window playback.) Search Here you can select to search for a picture (PIC) or a recorded file (REC).
DIVAR AN 3000 / DIVAR AN 5000 4 First time operation | en Playback Playback mode:1/4/9/16. (choose the required icon) mode – and channel In 1-window playback mode: you can select 1-16 channels from the drop-down menu – selection pane 29 In 4-window playback mode: you can select 4 channels according to your requirements. – In 9-window playback mode, you can switch between 1-8 and 9-16 channels. – In 16-window playback mode, you can switch between1-16 and 17-32 channels.
en | First time operation 5 DIVAR AN 3000 / DIVAR AN 5000 File list Double click to view a list of recorded files for the selected day. The file list displays the first channel of the recorded file (click the numbers above to select another channel). The system can display max 128 files at one time. Click once on a file to view the file details under the list, or double click a file to playback the file on the screen.
DIVAR AN 3000 / DIVAR AN 5000 First time operation | en 31 Backward play In normal play mode, left click the button, the file begins backward play. Click it again to pause current play. In backward play mode, click to restore normal play. In playback mode, click to play the next or the previous section (click continuously to watch consecutive files from the same channel. In normal play mode, press pause then click and to begin frame-by-frame playback.
en | First time operation 7 DIVAR AN 3000 / DIVAR AN 5000 Smart This function is only active when the system is playing a recording in full- search screen mode. to activate smart search. See following figure. Click Use your mouse to drag and select zone(s) in the window to detect motion. Click again to begin smart search. The system searches for motion in the chosen area(s). When ready, click again to stop smart search playback.
First time operation | en DIVAR AN 3000 / DIVAR AN 5000 8 Time bar 33 Display the record type and the period for the current search criteria. In 4-window playback mode, there are four corresponding time bars. In other playback modes, there is only one time bar. Click on a point in a colored zone in the time bar to begin playback at that point. When you first open Search/Play, the time bar begins at 0:00 hour, and will zoom to the period of the current playback when playing the file.
5 en | Maintenance DIVAR AN 3000 / DIVAR AN 5000 Maintenance Maintenance of this unit is limited to external cleaning and inspection, plus installing or replacing the internal lithium battery, the HDD or the DVD. The following figures show the DIVAR 3000 and the DIVAR 5000 (with top covers removed) and installed positions of the battery (1), DVD (2) and HDD (3): 1 2 3 Figure 5.1: DIVAR 3000 HDD and DVD installed 2013.11 | 1.
DIVAR AN 3000 / DIVAR AN 5000 Maintenance | en 35 1 3 2 Figure 5.2: DIVAR 5000 DVD and HDD installed See the following descriptions for installing these components: – Replace internal battery, page 37 – Install HDD in DIVAR 3000, page 38 – Install HDD in DIVAR 5000, page 41 – Install DVD in DIVAR 3000, page 45 – Install DVD in DIVAR 5000, page 47 Refer to the Appendix in the Operator Manual for recommended DVD and HDD types. Precaution – electrical voltage Danger! Electrical voltage.
en | Maintenance DIVAR AN 3000 / DIVAR AN 5000 Press pin Hold pin and connect cable Press pin Hold pin and connect cable Precaution – processor/wiring damage Caution! Possible processor/wiring damage ! When installing/removing a DVD/HDD, be careful that you do not damage vulnerable components (e.g. when using a screwdriver, make sure it cannot slip off the screw and damage the processor or wiring). See following figures. 2013.11 | 1.
DIVAR AN 3000 / DIVAR AN 5000 5.1 Maintenance | en 37 Attach ESD strap Figure 5.3: ESD strap The ESD strap is vital to prevent damage to ESD-sensitive parts when maintaining components in an opened DVR cabinet. Always attach the ESD strap around your wrist as follows: 1. Slide the expandable strap over your wrist. 2. Connect the clip on the flexible grounding cord to an unpainted ground point (or to an approved ground point). 3.
5.3 en | Maintenance DIVAR AN 3000 / DIVAR AN 5000 Install HDD in DIVAR 3000 This DVR can fit a maximum two SATA HDDs. See the following components and steps for installating HDD 1 (brackets and screws included in package): Figure 5.4: Install HDD 1 (DIVAR 3000) 2013.11 | 1.
DIVAR AN 3000 / DIVAR AN 5000 Maintenance | en 39 4x (1) (3) (2) 4x (4) 4x (6) (5) 4x (7) (8) (9) 4x (10) (11) (12) Figure 5.5: Install HDD 1 Install HDD 2 Install HDD 2 in the position of the optional DVD – see following figure: Bosch Security Systems Quick Reference Guide 2013.11 | 1.
en | Maintenance DIVAR AN 3000 / DIVAR AN 5000 Figure 5.6: Install HDD 2 Use the same install steps described for installing HDD 1. 2013.11 | 1.
DIVAR AN 3000 / DIVAR AN 5000 5.4 Maintenance | en 41 Install HDD in DIVAR 5000 See the following components and steps for installing HDD 1 (brackets and screws included in package): Figure 5.7: HDD install components (DIVAR 5000) Bosch Security Systems Quick Reference Guide 2013.11 | 1.
en | Maintenance DIVAR AN 3000 / DIVAR AN 5000 2x 4x (1) (2) (3) 2x 2x (4) (5) (6) (8) (9) 4x (7) 2x (10) (11) (12) Figure 5.8: Install HDD 1 Install HDD 1 and 2 Use the same procedure as for installing HDD 1, but include the following extra steps: 2013.11 | 1.
Maintenance | en DIVAR AN 3000 / DIVAR AN 5000 4x (5a) 43 4x (5b) (8b) (8a) (10a) Figure 5.9: Install HDD 1 and 2 Install HDD 3 and 4 Use the same install steps as for HDD 1 and 2, but install HDD 3 and 4 at the optional DVD location. See following figure. Bosch Security Systems Quick Reference Guide 2013.11 | 1.
en | Maintenance DIVAR AN 3000 / DIVAR AN 5000 Figure 5.10: Install HDD 3 and 4 2013.11 | 1.
DIVAR AN 3000 / DIVAR AN 5000 5.5 Maintenance | en 45 Install DVD in DIVAR 3000 See the following components and steps required for this installation (screws included in package): Figure 5.11: Install DVD components (DIVAR 3000) Bosch Security Systems Quick Reference Guide 2013.11 | 1.
en | Maintenance DIVAR AN 3000 / DIVAR AN 5000 4x (1) (3) (2) 4x (4) (5) (6) 4x (7) (8) (9) Figure 5.12: Install DVD in DIVAR 3000 2013.11 | 1.
DIVAR AN 3000 / DIVAR AN 5000 5.6 Maintenance | en 47 Install DVD in DIVAR 5000 See the following components and steps required for this installation (spacers and screws included in package): Figure 5.13: Install DVD components (DIVAR 5000) Bosch Security Systems Quick Reference Guide 2013.11 | 1.
en | Maintenance DIVAR AN 3000 / DIVAR AN 5000 2x (1) (3) (2) 4x (4) (6) (5) 4x 4x (7) (8) (9) 2x (10) (11) (12) Figure 5.14: Install DVD in DIVAR 5000 2013.11 | 1.
Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven The Netherlands www.boschsecurity.com © Bosch Security Systems B.V.