Conettix DX4020 Installation Guide EN Network Interface Module
Conettix DX4020 | Installation Guide | Contents Contents 1.0 2.0 3.0 3.1 3.2 4.0 4.1 4.2 4.3 4.4 5.0 5.1 5.2 6.0 6.1 6.2 6.3 6.4 6.4.1 6.4.2 6.5 6.5.1 6.5.2 7.0 8.0 2 Introduction ........................................................................................................................................................ 4 Overview .............................................................................................................................................................
Conettix DX4020 | Installation Guide | Trademarks . Certifications and Approvals Trademarks • Microsoft® and Windows® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Lantronix® is a registered trademark of Lantronix Corporation, registered in the U.S. and other countries. XPort™ with its patent-pending technology is a trademark of Lantronix, Inc. • • For Underwriters Laboratories, Inc.
Conettix DX4020 | Installation Guide | 1.0 Introduction 1.0 Introduction 2.0 Overview Use the Conettix DX4020 Ethernet Network Interface Module (Figure 1) for bi-directional communications over Ethernet networks.
Conettix DX4020 | Installation Guide | 3.0 Installation . 3.0 Installation Inform the operator and the local authority having jurisdiction (AHJ) before installing the DX4020 in an existing system. Disconnect all power to the control panel before installing the DX4020. 3.2 Wiring Run the wiring connections from the DX4020 data bus terminals to the compatible control panel’s data bus terminals (Figure 4). Refer to the associated control panel documentation for complete wiring instructions.
Conettix DX4020 | Installation Guide | 3.0 Installation Figure 5 shows an example of wiring the DX4020 to a control panel. Figure 5: Wiring the DX4020 to a Control Panel 4 1 2 3 43489F LEDs Off When Normal YEL RED Charging Status Low Battery - 12.1 VDC Digital Alarm Communicator Transmitter 1 2 CAUTION: See Manual For Power Requirements Relating to Terminals + AUX POWER 4 BATTERY NEGATIVE ONLY 5 Maximum Charging Current 1.4 Amps.
Conettix DX4020 | Installation Guide | 4.0 DIP Switch Settings . Figure 7: 4.0 DIP Switch Settings Use the DIP switch settings in Sections 4.1 through 4.4 for the DX4020 network communication. 4.
Conettix DX4020 | Installation Guide | 5.0 LEDs 4.3 DS7400Xi Control Panel Use Option Bus Addresses 13 and 14 (Figure 9 and Figure 10) to send reports. Use Option Bus Address 13 to connect to the RPS for remote programming. Figure 9: DIP Switch Setting for Address 13 1 = 2 = 5.0 LEDs 5.1 Ethernet and Serial Figure 12 and in Table 3 identify and describe the DX4020’s four bus and serial status LEDs. Use the P2 jumper to enable (jumper on) or disable (jumper off) LED operation.
Conettix DX4020 | Installation Guide | 6.0 IP Address Programming . 5.2 6.1 XPort Figure 13 and Table 4 identify and describe the DX4020’s two bi-color LEDs that are built into the front of the XPort connector. Figure 13: XPort LEDs 2 1 Factory-Programmed IP Configuration The DX4020 is shipped with the following default IP settings: • Default IP Configuration Number: DHCP • Default Port: 7700 • Default DHCP Device Name: Cxxxxxx xxxxxx = last six digits of the MAC address 6.
Conettix DX4020 | Installation Guide | 6.0 IP Address Programming 6.4 Assigning the Initial IP Address Before proceeding, read this entire section. Ensure that the DX4020 has power and the Ethernet Network RJ-45 connection is in place. Ensure that the PC used to configure the DX4020 and the DX4020 itself are on the same gateway (the device connecting the LAN to the WAN). 6.4.2 1. From the Start Menu, select Start Æ Run to open a DOS window. 2. At the Run dialog box, type COMMAND and click [OK].
Conettix DX4020 | Installation Guide | 6.0 IP Address Programming . 6.5 Using Telnet to Complete Configuration 6. Click Connect and wait a few seconds for the following failed message to appear. 7. Click OK to open the Telnet window again. 8. Repeat Step 3 in Section 6.4.2 Using the ARP Command, on page 10. 9. This time, leave all but the Port field the same. Type 9999 in the Port field. Refer to Section 6.5.1 Using Windows 98 Telnet when using Windows 98. Refer to Section 6.5.
Conettix DX4020 | Installation Guide | 6.0 IP Address Programming If you press [Enter] within 5 sec. of seeing the “Press Enter to go into Setup Mode” message, the following screen appears. 12. Press [0] then [Enter] to set up the basic Server configuration. If the DX4020 was previously programmed with an IP address, it appears in parentheses. For example, if the DX4020 was originally programmed to IP address 172.30.3.36, change it to 190.200.128.219. 13. Press [1][9][0][.][2][0][0][.][1][2 [8][.
Conettix DX4020 | Installation Guide | 6.0 IP Address Programming . 17. Press [Enter] after entering the correct number of bits for the Netmask. Table 5: Netmask Addresses Host Bits Netmask Host Bits Netmask 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 255.255.255.254 255.255.255.252 255.255.255.248 255.255.255.240 255.255.255.224 255.255.255.192 255.255.255.128 255.255.255.0 255.255.254.0 255.255.252.0 255.255.248.0 255.255.240.0 255.255.224.0 255.255.192.0 255.255.128.0 255.255.0.
Conettix DX4020 | Installation Guide | 6.0 IP Address Programming 24. Press [Enter] to accept CC as the default ConnectMode. If CC is not the default, type cc and press [Enter] to change it. 26. Press [Enter] four times to specify 0.0.0.0 for remote IP address. 25. Enter the appropriate Datagram value based on the type of control panel. Refer to Table 6. 28. To enable encryption, select 6- Security from the Main Menu and follow Steps 29 through 33.
Conettix DX4020 | Installation Guide | 6.0 IP Address Programming . 35. At the Main Menu, select 9 to save and close the telnet session. The following message appears. 4. At the Microsoft Telnet> prompt, type open (space) IP ADRESS (space) PORT NUMBER, such as open 172.17.10.70 1. The connection fails the first time. This is normal. 36. Click OK to close the telnet window. 5. 37. To verify that the IP address is properly configured, ping the IP address and check for a response.
Conettix DX4020 | Installation Guide | 7.0 Control Panel Programming 7.0 Control Panel Programming Table 7 lists available documentation for DX4020 to control panel programming.
Conettix DX4020 | Installation Guide | 8.0 Specifications . Notes Bosch Security Systems, Inc.
Bosch Security Systems, Inc.