Installation guide

Conettix DX4020 | Installation Guide | 6.0 IP Address Programming
.
Bosch Security Systems, Inc. | 1/09 | F01U045288-05 15
35. At the Main Menu, select 9 to save and close the
telnet session.
The following message appears.
36. Click OK to close the telnet window.
37. To verify that the IP address is properly
configured, ping the IP address and check for a
response.
- At the C:\> prompt, type PING <IP
Address> and press [Enter].
- Four reply messages appear, verifying the
DX4020 is communicating with the network.
- DX4020 configuration is complete. Perform
this procedure for additional DX4020s.
6.5.2 Using Windows 2000/XP Telnet
To complete the DX4020 IP address configuration, you
must launch a telnet session.
Ensure that you are logged into Windows
2000 or XP with an administrator privilege
level.
The following example uses the IP address
of 172.17.10.70 and the MAC Address of
00-20-4a-72-04-0e.
1. At the Start Menu, select Start Æ Run to open a
DOS window.
2. At the Run dialog box, type COMMAND and
click [OK].
A command prompt window appears.
3. At the C:\> prompt, type telnet and press [Enter].
4. At the Microsoft Telnet> prompt, type open
(space) IP ADRESS (space) PORT NUMBER,
such as open 172.17.10.70 1.
The connection fails the first time. This is normal.
5. Enter the same sequence at the prompt, but use
port 9999 instead of 1, such as open 172.17.10.70
9999.
Pressing [F3] shows the last line typed,
Backspace over the port entry, and change
it to 9999.
6. Press [Enter] to return to the DX4020 Setup Menu.
7. To program a device, follow Steps 11 through 35 in
Section 6.5.1 Using Windows 98 Telnet, starting on
page 11.
8. Close Telnet by clicking the
icon in the upper
right-hand corner.