Installation manual

Fitting the connection set for two rows (accessory)
6 720 613 055 (2006/04)
39
9 Fitting the connection set for two rows (accessory)
The connection set (Fig. 59, Item 9) is available as an
accessory, and connects two rows of collectors.
Scope of supply (Fig. 59)
Fitting additional end caps
Use the end caps to close up any collector connections
not in use (Fig. 59, Item 1, see Chapter 6.1.2 "Fitting the
end cap", page 30).
Installing the connection set
B Remove double threaded fitting and compression fit-
ting from connection pipe.
B Insert gasket (Fig. 60, Item 2) into nut.
B Insert bracket (Fig. 60, Item 3) into nut, align and
screw tight.
B Push connection pipe (Fig. 60, Item 1) onto the col-
lector connections and fix in place using brackets
(Fig. 60, Item 4) from the connection kit.
Extending the connection set
B Fit olive (Fig. 61, Item 2) and nut to bracket (Fig. 61,
Item 3).
B Push copper pipe (cut to appropriate length) (22 mm,
Fig. 61, Item 1) into compression fittings.
B Tighten the fittings.
Fig. 59 Schematic diagram and scope of supply
Fig. 60 Connection set between two collector rows
Fig. 61 Lengthening the connection pipe
63043966.27-1.SD
63043966.27-1.SD
6
2
1
3
4
5
9
1
1
7
8
63043966.29-1.SD
63043966.29-1.SD
3
1
4
2
63043966.32-1.SD
63043966.32-1.SD
3
1
2
i
USER NOTE
Fit as many connection parts as possible
to the collectors on the ground. This
makes installation on the roof easier.
Item 1: End cap 2 ×
Item 2: Connection pipe 1 ×
Item 3: Bracket 1 ×
Item 4: Gasket 1 ×
Item 5: Large diameter washer 1 ×
Item 6: Clamping disc 1 ×
Item 7: Olive 2 ×
Item 8: Nut 1 ×
i
USER NOTE
If you need to shorten the connection pipe
(Fig. 60, Item 1), observe the installation
steps described in "Making the sealing
face:", page 38.