5.2 Fitting additional roof battens
When laying the facing panels and collectors in place,
there will have to be additional roof battens of equal
height to those already on the building.
Length of additional roof battens
The minimum length of the additional battens (Fig. 9,
Item 2 is the width of the collector array (Table 5,
page17, dim. A) plus approx. 10 cm for the side clips
(Fig. 9, Item 1).
i
USER NOTE
As an alternative to additional roof bat-
tens, those already present around the
collector array area can be adjusted to the
same dimensions as the additional roof
battens.
These instructions describe installation
using additional roof battens.
CAUTION!
BUILDING DAMAGE
from leaks in the roof.
B Fasten batten butt joints to the joist
or ensure that they are adequately se-
cure, e.g. by fastening them to the al-
ready existing roof battens (Fig. 9,
Item 3 and Fig. 13, Item 2).
Fig. 9 Length of additional roof battens (here: first lower roof batten with anti-slip protection)
Item 1: Clip
Item 2: Additional roof battens
Item 3: Joining the additional roof battens