Installation manual

Header connection
6 720 613 057 (2006/04)
31
8.2.1 Fitting the air vent valve under the roof
B Push connection pipe (Fig. 36, Item 3) onto the flow
connection on the collector array and fix in place
using bracket (Fig. 36, Item 5).
B Feed connection pipe together with the sensor cable
through the de-airing tile (Fig. 36, Item 4) and
through the roof insulation.
Perform the same procedure with the return connection.
B Remove nut and compression fitting from connection
pipe.
B Firmly screw connection pipe (Fig. 36, Item 3) and
double threaded fitting (Fig. 36, Item 1) into air pot
(O-ring gasket).
B Connect header pipe to double threaded fitting with
compression fitting (Fig. 36, Item 1).
Fig. 36 Fitting the air vent valve under the roof
Item 1: Double threaded fitting with O-ring
Item 2: Air pot
Item 3: Connection pipe
Item 4: De-airing tile
Item 5: Bracket