Operation Manual
Table Of Contents
- Table of Contents
- 1 Browser connection
- 2 System Overview
- 3 Operation via the browser
- 3.1 Livepage
- 3.2 Playback page
- 4 Settings Overview
- 5 Basic Mode
- 6 Advanced General Settings
- 7 Web Interface
- 8 Camera
- 9 Encoder Settings
- 10 Recording
- 11 Alarm
- 12 Setting up VCA
- 13 Network
- 13.1 Network Access
- 13.1.1 Automatic IP assignment
- 13.1.2 IP V4 address
- 13.1.3 IP V6 address
- 13.1.4 DNS server address 1
- 13.1.5 Video transmission
- 13.1.6 TCP rate control
- 13.1.7 HTTP browser port
- 13.1.8 HTTPS browser port
- 13.1.9 RCP+ port 1756
- 13.1.10 Telnet support
- 13.1.11 Interface mode ETH
- 13.1.12 Network MSS [Byte]
- 13.1.13 iSCSI MSS [Byte]
- 13.1.14 Network MTU [Byte]
- 13.1.15 Enable DynDNS
- 13.1.16 Provider
- 13.1.17 Host name
- 13.1.18 User name
- 13.1.19 Password
- 13.1.20 Force registration now
- 13.1.21 Status
- 13.2 Advanced
- 13.3 Multicast
- 13.4 Image Posting
- 13.5 Accounts
- 13.6 IP V4 filter
- 13.1 Network Access
- 14 Service

Camera Browser Interface Recording | en 61
Bosch Security Systems Software manual AM18-Q0635 | v5.8 | 2013.05
10.2.1 Recording track selection
Standard and alarm recording can be defined for the two
recording tracks. You must first select the track before setting
up the standard and alarm recording parameters.
1. Click the Recording 1 entry in the list.
2. Set up the standard and alarm recording parameters for
track 1 as described below.
3. Click the Recording 2 entry in the list.
4. Set up the standard and alarm recording parameters for
track 2 as described below.
Recording includes
Specify whether, in addition to video data, audio or metadata
(for example alarms or VCA data) should also be recorded. (To
change the global audio format, click the audio recording
format link.)
Note:
Including metadata could make subsequent searches of
recordings easier but it requires additional memory capacity.
Without metadata, it is not possible to include video content
analysis in recordings.
10.2.2 Standard recording
Select the mode for standard recordings:
– Continuous: the recording proceeds continuously. If the
maximum recording capacity is reached, older recordings
are overwritten automatically.
– Pre-alarm: recording takes place in the pre-alarm time,
during the alarm and during the post-alarm time only.
– Off: no automatic recording takes place.
Stream
Select the stream to be used for standard recordings:
– Stream 1
– Stream 2
– I-frames only