Operation Manual

6 720 645 350 (2010/09)
Operation with flap open | 21
5.5 Selecting and adapting a DHW
program
At the factory, a DHW program is set that will suit
most applications. The DHW program comprises:
a program for DHW heating
a program for a DHW circulation pump
Both programs have already been matched to
each other and are enabled.
In this chapter you will discover how to either
disable programs and combine them with the
active heating program, or how to adjust them
individually.
Factory settings of the DHW heating program
Factory settings of the DHW circulation pump program
Day Program points
P1 P2 P3 to P6
°C / On/Off
Switching
time
°C / On/Off
Switching
time
°C / On/Off
Switching
time
Monday to
Friday
60 °C
1)
/ On
2)
1) DHW heating with a DHW cylinder
2) DHW heating with a combi boiler
05:00 15 °C
1)
/ Off
2)
23:00
Saturday 60 °C
1)
/ On
2)
06:00 15 °C
1)
/ Off
2)
23:00
Sunday 60 °C
1)
/ On
2)
07:00 15 °C
1)
/ Off
2)
23:00
Tab. 6 Factory settings of the DHW heating program
Day Program points
P1 P2 P3 to P6
On/Off
Switching
time On/Off
Switching
time On/Off
Switching
time
Monday to
Friday
On
06:00 Off 23:00
Saturday On 07:00 Off 23:00
Sunday On 08:00 Off 23:00
Tab. 7 Factory settings of the DHW circulation pump program (the DHW circulation pump program is
only available for DHW heating with a DHW cylinder)