Operation Manual
6 720 645 350 (2010/09)
Display | 7
Item Symbol Designation Explanation
1 Temperature
display
• The current room temperature is displayed if the
controller has been mounted on the wall and set up
correctly.
• The current flow temperature is displayed if the
controller has been fitted in the heating appliance or
has been mounted on the wall and set up correctly.
2 Time and day Current time and day.
3 Flashingseg
ment
Current time (1 segment = 15 minutes, here 13:45 h to
14:00 h) or switching time in the heating program.
4 Full
segments
Period for Comfort mode (high room temperature) or
DHW heating (high DHW temperature),
1 segment = 15 minutes.
5 Empty
segments
Period for mode (average room temperature) or DHW
heating (average DHW temperature),
1 segment = 15 minutes.
6 No segment Period for Frostmode (low room temperature) or DHW
heating (low DHW temperature).
7 Header Title of the higher menu level, program etc.
8 3 Text lines Menu points, info texts, setting values etc.
9 Back Return to the higher menu level.
10 Further text An arrow indicates if the displayed text is longer than 3
lines. Turning the rotary selector makes the additional
text visible.
11 Burner
operation
The heating appliance heats.
12 Operating
mode
Current operating mode Comfort/Economy/Frost.
13 Automatic
mode
Automatic changeover of the operating mode at the
selected switching times in accordance with the heating
program.
14 Holiday The holiday program is active.
Tab. 2 Symbols in the display
12
h
15
9
3