Operation Manual

6 720 645 349 (2010/09)
Operation | 19
5 Operation
5.1 Changing the room temperature
and operating mode
5.1.1 Changing the room temperature with
(with time limit)
You can also permanently change the required
room temperature, Æ chapter 6.3.2 on page 33.
This function is only available if the heating
system is not regulated via remote control
FB 100:
B Set the required room temperature with .
If the operating mode selector is set to
:
The new temperature applies until the next
switching point. Afterwards, the set
temperature applies for the switching
period.
If the operating mode selector is set to
/ / : The new temperature applies
until the selector position is changed.
Afterwards, the set temperature applies to
the selected operating mode.
5.1.2 Changing the operating mode with
(with time limit)
To permanently change the operating mode,
Æ chapter 5.1.4 on page 20.
This function is only available if the heating system
is not regulated via remote control FB 100 and
automatic mode has been activated :
B Press briefly to bring forward the next
switching time and the associated operating
mode Comfort / Economy / Frost to
the current time.
The display shows the changed details.
B Press and hold and simultaneously turn
the rotary selector to change the next
switching point. As a maximum, the switching
time can be changed between the current
time and the switching time after next.
If the next switching time of the heating
program is exceeded, the function will be
reset, and automatic mode will be active
again.
Cancelling the function early:
B Press briefly again.
The controller provides the option
of setting the required room
temperature for the operating mode
concerned. The temperature given
is not the actual room temperature.
It is an orientation value that
influences the required flow
temperature.
The function can be used in
situations such as going to bed
earlier, being away from home
longer or returning early.