Operation Manual
6 720 645 349 (2010/09)
28 | Adjusting the MAIN MENU
6.1.3 MAIN MENU: Domestic hot water
Parameter – – –
33
Heating levels – – –
Comfort 21.0 °C 0.0 °C ... 30.0 °C (not lower than
Economy)
°C
Economy 15.0 °C 0.0 °C ... 30 °C (not lower than
Frostand not higher than
Comfort)
°C
Frost 5.0 °C 0.0 °C ... 30 °C (not higher than
Economy)
°C
Heating up speed Normal Economy | Normal | Fast
Menu structure Heating Factory setting Setting range
Personal
setting
Description
frompage
Menu structure
Domestic hot water
Factory
setting
Setting range
Personal
setting
Description
from page
DHW and DHW circulation pump Separate
programmes
Separate programmes | As
heating programme
34
DHW programme
1)
– – –
Edit – – –
All days Æ Table on page 71
P1, P2 ... P6
Mon - Fri
P1, P2 ... P6
Sat + Sun
P1, P2 ... P6
Monday, Tuesday... Sunday
P1, P2 ... P6
Reset factory settings No No | Yes
View – – –
All days | Mon - Fri | Sat +
Sun | Monday, Tuesday...
Sunday
– – –