Operation Manual

6 720 645 349 (2010/09)
Viewing information | 41
Heating system
Operating mode Auto – Comfort | Auto –
Economy | Auto – Frost |
Comfort | Economy |
Frost | Holiday – Auto |
Holiday – Comfort | Holiday
– Economy | Holiday –
Frost | Floor drying
waiting | Floor drying
running
Current operating mode or special mode for the
heating system.
Required room temp 25.0 °C Room temperature called for by the controller or the
remote control FB 10 (only if "Room influence" is
active).
Current room temperature 22.0 °C Room temperature measured at the controller
(only with wall mounted controllers).
Room temperature FB10 23.0 °C Room temperature captured by the remote control
FB 10.
Required CH flow
temperature
75.0 °C Flow temperature calculated and requested by
controller.
Current CH flow
temperature
47.0 °C Flow temperature captured in the heating circuit.
Heating pump On | Off Heating circuit pump switching state.
Current mixer setting 85 % open Current level of opening of the heating circuit mixer.
Domestic hot water
Operating mode Immediate DHW | Auto On |
Auto Off | Holiday – Auto |
Holiday On | Holiday Off
Current operating mode or special mode for DHW
with combi boiler.
Immediate DHW | Thermal
disinfection | Auto | Holiday
– Auto | Holiday 15 °C
Current operating mode or special mode for DHW
cylinder.
Required DHW temperature 60.0 °C DHW temperature required by controller.
Current DHW temperature 40.0 °C Current measured DHW temperature.
Domestic hot water status Running | Off Current status of DHW heating.
Last thermal disinfection Completed | Cancelled |
Running
Result of the last thermal disinfection.
Customer service
Phone number (Telephone number) Telephone number of heating contractor
(system installer).
Name (Name) Name of heating contractor (system installer).