44 | Menu settings INSTALLER SETTINGS (contractors only)
8.1.2 INSTALLER SETTINGS: Heating parameters
8.1.3 INSTALLER SETTINGS: Solar system config
Menu structure
Heating parameters
Factory
setting
Setting range
Personal
setting
Description
from page
Heating circuit type Radiators Foot point/End point | Underfloor
heating | Radiators | Convectors
47
Foot point 25°C 10°C ... 85°C °C 49
End point 75 °C 30 °C ... 85 °C °C 49
Design flow temp. 75 °C 30 °C ... 85 °C °C 49
Maximum CH flow temperature 80 °C 30 °C ... 85 °C °C 49
Room influence 30 % 0 % ... 100 % % 49
Room influence enabled for
levels
Eco/Frost Eco/Frost | Comfort/Eco/Frost
49
Sensor(s) used for room
influence
Lower
temperature
Sensor on FB10 | Internal sensor |
Lower temperature
(only with FB 10)
49
Room temperature offset 0.0 K – 5.0 K ... 5.0 K K 50
Heating off until lower level
reached
Yes No | Yes
50
Heating off at outside
temperature
20.0 °C 10.0 °C ... 25.0 °C, 99.0 °C
(= function off)
°C
50
Freezing risk at outside
temperature
3.0°C – 5.0°C ... 10.0°C °C
50
Calibrate room temp sensor on
FB10
0.0 K – 3.0 K ... 3.0 K (only with FB 10) K
51
Mixer running time 140 s 10 s ... 600 s s 51
Minimum outside temperature – 15 °C – 30 °C ... 0 °C °C 51
Building storage capacity 50 % 0 % ... 100 % % 51
Calibrate internal room temp
sensor
0.0 K – 3.0 K ... 3.0 K K
51
Menu structure
Solar system config
Factory
setting
Setting range
Personal
setting
Description
from page
Solar sys option E Thermal
disinfection
No No | Yes
53