46 | Menu settings INSTALLER SETTINGS (contractors only)
8.1.6 INSTALLER SETTINGS: Cust service address
8.1.7 INSTALLER SETTINGS: System info
8.1.8 INSTALLER SETTINGS: Floor drying
Menu structure
Cust service address
Example Setting range
Personal
setting
Description
from page
Telephone number 012345 6789 Max. 20 characters
55
Name Heating
contractor
Max. 20 characters
Menu structure
System info
Example Setting range
Personal
setting
Description
from page
Installation date 22.10.2010
(activated on
commissioning)
– –
56
Boiler part number 7 777 777 777
(data from heating
appliance)
– –
Boiler date of manufacture 27.06.2010 (data
from heating
appliance)
– –
Controller part number and
model
7 777 777 777
FW 100 (fixed
factory setting)
– –
Controller date of manufacture 27.06.2010 (fixed
factory setting)
– –
Controller software version JF11.12 (fixed
factory setting)
– –
Menu structure
Floor drying
Factory setting Setting range
Personal
setting
Description
from page
Cancel floor drying
1)
No No | Yes
56
Maximum CH flow temperature 25 °C 25 °C ... 60 °C °C
Maintain max CH flow temp for 1 d 1 d ... 20 d d
Total floor drying time calculated calculated... 60 d (not lower than
"Maintain max CH flow temp for")
Start date – – . – – . – – – – Today ... 31.12.2099
(in year/month/day steps)
Start time : – – 00:00 ... 23:59
(in hour/minute steps)
1) Only available if "Floor drying" is active.