Operation Manual

1 609 929 M98 | (11.1.08) Bosch Power Tools
18 | English
Hook the fitting saw blade 12 onto the saw blade
driving pin 17 closest to the motor (c). Swing/
work the saw blade into the saw blade guide 19
and allow the nose of the saw blade to engage in
the opening of the sword 1.
Hook the second saw blade onto the free saw
blade driving pin 17 (d). Swing/work the saw
blade into the saw blade guide 19. Release the
SDS button 9.
From above, press on the second saw blade 12
until the nose of the saw blade engages in the
opening of the sword 1.
f Check the saw blades for firm seating.
A loose saw blade can fall out and cause injury.
Mount the saw blade guard 11 onto the saw
blades 12.
Removing the Saw Blades (see figures K
L)
Press the SDS button 9. Pull both saw blades 12
close to the saw blade driving pins 17 together
out of the saw blade guide (c).
Slide the saw blades 12 apart in longitudinal
direction (d) and, one after the other, pull them
out of the saw blade guide 19 (e). When attempt-
ing to remove both saw blades at the same time,
the saw blades block each other.
Dust/Chip Extraction
f Dusts from materials such as lead-containing
coatings, some wood types, minerals and
metal can be harmful to one’s health. Touch-
ing or breathing-in the dusts can cause aller-
gic reactions and/or lead to respiratory infec-
tions of the user or bystanders.
Certain dusts, such as oak or beech dust, are
considered as carcinogenic, especially in con-
nection with wood-treatment additives (chro-
mate, wood preservative). Materials contain-
ing asbestos may only be worked by
specialists.
Use dust extraction whenever possible.
Provide for good ventilation of the working
place.
It is recommended to wear a P2 filter-class
respirator.
Observe the relevant regulations in your coun-
try for the materials to be worked.
Extraction Duct (see figure F)
Hook on the extraction duct 8 at the housing
below handle 6 and allow it to engage onto the
catches 10.
To remove the extraction duct 8, spread it at the
catches 10 and remove toward the rear.
Connecting the Dust Extraction
Insert a vacuum hose (diameter 35 mm; acces-
sory) into the vacuum connection 7. Connect the
vacuum hose to a vacuum cleaner (accessory).
The vacuum cleaner must be suitable for the
material being worked.
When vacuuming dry dust that is especially de-
trimental to health or carcinogenic, use a special
vacuum cleaner.
Operation
Starting Operation
f Observe correct mains voltage! The voltage
of the power source must agree with the
voltage specified on the nameplate of the
machine. Power tools marked with 230 V can
also be operated with 220 V.
Switching On and Off
f When switching on the machine, the saw
blades may not face against or touch any-
thing.
Two switch on the machine, press and hold the
safety switch 4 on the left or right and then press
the On/Off switch 5.
To switch off the machine, release the On/Off
switch 5.
When working longer periods at low stroke rate,
the machine can heat up considerably. Remove
the saw blades and cool down the machine by
running it for approx. 3 minutes at maximum
stroke rate.
OBJ_BUCH-594-001.book Page 18 Friday, January 11, 2008 9:21 AM