Operation Manual

English | 13
Bosch Power Tools 1 609 92A 0K9 | (1.4.14)
Product Features
The numbering of the product features shown refers to the il-
lustration of the measuring tool on the graphic page.
1 Display
2 Measuring button
3 Button for area/surface, volume and indirect height
measurement (Pythagoras)
4 Delete / On/Off button **
5 Minus button
6 Button for selection of the reference level
7 Fixture for carrying strap
8 Plus button
9 Length and continuous measurement button
10 Battery lid
11 Laser beam outlet
12 Reception lens
13 Serial number
14 1/4" thread
15 Laser warning label
16 Latch of battery lid
17 Protective pouch
18 Tripod*
19 Laser viewing glasses*
20 Laser target plate*
* The accessories illustrated or described are not included as
standard delivery.
** Keep button pressed to call up the extended functions.
Display Elements
a Measured-value lines
b Result line
c Measuring functions
d Laser, switched on
e Measurement reference level
f Temperature warning
g Battery low indicator
h “ERROR” indication
Assembly
Inserting/Replacing the Batteries
Using alkali-manganese or rechargeable batteries is recom-
mended for operation of the measuring tool.
Less measurements are possible when using 1.2 V recharge-
able batteries than with 1.5 V batteries.
To open the battery lid 10, press the latch 16 and remove the
battery lid. Insert the batteries/rechargeable batteries. When
Laser beam diameter (at 25 °C) approx.
–at 10m distance
–at 50m distance
6mm
35 mm
Automatic switch-off after approx.
–Laser
Measuring tool (without measurement)
20 s
5min
Batteries
Rechargeable batteries
2x1.5VLR03(AAA)
2x1.2VHR03(AAA)
Battery live, approximately
Individual measurements
Continuous measurement
10000
D)
2.5 h
D)
Weight according to EPTA-Procedure 01/2003 0.14 kg
Dimensions
53x114x30mm
Degree of protection
IP 54 (dust and splash water protected)
Digital Laser Measure GLM 50Professional
A) The working range increases depending on how well the laser light is reflected from the surface of the target (scattered, not reflective) and with in-
creased brightness of the laser point to the ambient light intensity (interior spaces, twilight). In unfavourable conditions (e.g. when measuring out-
doors at intense sunlight), it may be necessary to use the target plate.
B) For measurements from the rear measuring-tool edge. In unfavourable conditions (e.g. at intense sunlight or an insufficiently reflecting surface),
the maximum deviation is ±10 mm per 50 m. In favourable conditions, a deviation influence of ±0,05 mm/m must be taken into account.
C) In the continuous measurement function, the maximum operating temperature is +40 °C.
D) Less measurements are possible when using 1.2 V rechargeable batteries than with 1.5 V batteries. The battery life listed refers to measurements
without display illumination.
The measuring tool can be clearly identified with the serial number 13 on the type plate.
Length measurement
Continuous measurement
Area/surface measurement
Volume measurement
Simple Pythagoras Measurement
OBJ_BUCH-1444-005.book Page 13 Tuesday, April 1, 2014 10:46 AM