Safety Instructions

-14-
Technical Data
Laser Measure GLM165-22, GLM165-27C
Article Number 3.601.K72.S10
3.601.K72.T10
Measuring range (typical): 6 in – 165 ft
(0.15 – 50 m)
A
Measuring accuracy (typical)
±1/16 in (±1.6 mm)
B
Lowest indication unit 1/32 in (0.8 mm)
General
Operating temperature +14 °F to 113 °F
(-10 °C to 45 °C)
C
Storage temperature -4 °F to 158 °F
(-20 °C to 70 °C)
Relative air humidity, max. 90 %
Max. altitude: 2000 m
Pollution degree according to
IEC 61010-1:
2
D
Laser class 2
Laser type 635 nm, <1 mW
Laser beam diameter at 77 °F
(25 °C) approx.
– at 33 ft (10 m) distance
– at 165 ft (50 m) distance
4/11 in (9 mm)
1-3/4 in (45 mm)
Weight 0.22 lb (0.1 kg)
Dimensions 4.2 x 1.8 x 0.9 in
(106 x 45 x 24 mm)
Automatic switch-off after approx.
– Laser
– Laser measure (without
measurement)
20 s
E
5 min
F