Safety Instructions

-15-
Degree of protection IP65
Batteries 2 x 1,5 V LR6 (AA)
Laser Measure GLM165-27C only
Indirect Distance Measurement and Vial
Measuring range 0°–360° (4 x 90°)
Angle Measurement
Measuring range 0°–360° (4 x 90°)
Measuring accuracy (typical) ±0.2°
G,H, I
Lowest indication unit 0.1°
Data transmission
Bluetooth® Bluetooth® 4.2
(Low
Energy)
J
A
The working range increases depending on how well
the laser light is reflected from the surface of the
target (scattered, not reflective) and with increased
brightness of the laser point to the ambient light
intensity (interior spaces, twilight). In unfavorable
conditions, e.g., with extreme illumination or a badly
reflecting surface, the measuring range may be lim-
ited.
B
In favorable conditions, a deviation influence of ±0.05
mm/m must be taken into account. In unfavorable
conditions, e.g., with extreme illumination, badly re-
flecting surface or the room temperature deviating
heavily from 77 °F (25 °C), the maximum deviation
can be up to ±3.0 mm. Additionally, a deviation influ-
ence of 0.15 mm/m must be taken into account.
C
In the real time measuring function, the maximum
operating temperature is 104 °F (40 °C).
D
Non-conductive soiling only, whereby occasional
temporary conductivity caused by condensation is
expected.