1 609 929 J80 • 06.03
Fault Finding and Troubleshooting
Maintenance and Service
Maintenance and Cleaning
Before any work on the radio charger, pull the
mains plug from the power outlet.
If the radio charger should fail despite the care
taken in manufacturing and testing procedures,
repair should be carried out by an after-sales serv-
ice centre for Bosch power tools
In all correspondence and spare parts orders,
please always include the 10-digit article number
on the type plate of the radio charger. The type
plate is located on the bottom side of the radio
charger.
Mains Cable
The mains cable is fitted with a special safety con-
nection. The mains cable may only be replaced by
an authorised after-sales service agent for Bosch
power tools.
WARNING! This appliance must be earthed.
Important instructions for connecting a new
3-pin plug.
The wires in the cable are coloured according to
the following code:
Do not
connect the blue or brown wire to the earth
terminal of the plug.
Important: If for any reason the moulded plug is
removed from the cable of this machine, it must be
disposed of safely.
Problem Possible Cause Corrective Measure
Radio or CD player
not operative.
Mains plug not plugged in. Plug in the mains plug.
For battery operation: Battery not fully
inserted.
Completely insert the battery.
For battery operation: Battery dis-
charged.
Charge the battery by plugging in
the mains plug.
Insufficient radio
reception.
Bad location. Place the radio charger at a different
location.
Aerial not aligned optimally. Turn the aerial to other directions.
12 V connection not
operative.
Fuse for 12 V connection not inserted. Insert a 5 x 20 mm 1 A fuse.
Fuse for 12 V connection defective. Replace the fuse.
Power outlets 43 not
operative.
Mains plug not plugged in. Plug in the mains plug.
Radio charger does not
operate.
Mains plug not plugged in. Plug in the mains plug.
Software error. If the display is not lit up when switched
on, the software in the radio charger
must be reset. Pull the mains plug
and/or remove the battery and wait for
30 seconds.
Faulty clock display. Clock batteries dead. Replace the AAA batteries and reset
the clock.
strain relief
live = brown
To be fitted
by a qualified
professional onl
y
neutral = blue
earth = green/yellow
1 609 929 J80.book Seite 9 Montag, 27. März 2006 3:27 15