Product specifications

1 609 929 U13 | (9.12.09) Bosch Power Tools
30 | English
Correction of Malfunctions
Problem Cause Corrective Measure
The pneumatic tool is ready for
operation, but no staples
(GTK 40) or brads (GSK 50) are
discharged.
A staple (GTK 40) or a brad (GSK 50) has
become jammed in the shot duct.
–Clear the jam.
(See “Clearing Jams”, page 27)
The magazine slider is 11 defective. – Clean and lubricate the magazine slider
11 as required and make sure that the
magazine 8 is not dirty/soiled.
The spring of the magazine slider is too
week or defective.
– Contact an authorised service agent for
Bosch power tools.
Have the component replaced there.
The fasteners being used are not
permitted.
Use only original accessories.
Only the fasteners (nails, staples, etc.)
specified in table “Technical Data” may
be used.
The magazine 8 is empty. Refill the magazine.
(See “Loading the Magazine”, page 25)
The staples (GTK 40) or brads
(GSK 50) are discharged very
slowly and with too little pres-
sure.
The rated pressure of the compressed-
air supply is too low.
Increase the compressed-air supply.
8 bar may not be exceeded.
The driver blade is damaged. Use only the lubricants recommended
by Bosch.
(See “Lubricating the Pneumatic Tool”,
page 28)
The sealing ring of the piston is worn or
damaged.
– Contact an authorised service agent for
Bosch power tools.
Have the component replaced there.
The buffer is worn. Contact an authorised service agent for
Bosch power tools.
Have the component replaced there.
The length and diameter of supply-air
hose 17 do not correspond with the data
of this pneumatic tool.
Use a supply-air hose with the correct
dimensions.
(See “Technical Data”, page 24)
The supply-air hose 17 is bent/creased. Correct the bend/crease in the supply-
air hose.
The staples (GTK 40) or brads
(GSK 50) are driven in too
deep.
The rated pressure of the compressed-
air supply is too high.
Reduce the compressed-air supply.
4 bar may not be fallen below.
The depth stop is set too deep. Adjust the depth stop to the desired
depth.
(See “Adjusting the Depth Stop”,
page 27)
The buffer is worn. Contact an authorised service agent for
Bosch power tools.
Have the component replaced there.
OBJ_BUCH-1038-001.book Page 30 Wednesday, December 9, 2009 1:38 PM