Operation Manual

English | 31
Bosch Power Tools 1 619 P08 849 | (12.3.10)
Dust/Chip Extraction
f Dusts from materials such as lead-containing
coatings, some wood types, minerals and
metal can be harmful to one’s health. Touch-
ing or breathing-in the dusts can cause aller-
gic reactions and/or lead to respiratory infec-
tions of the user or bystanders.
Certain dusts, such as oak or beech dust, are
considered as carcinogenic, especially in
connection with wood-treatment additives
(chromate, wood preservative). Materials
containing asbestos may only be worked by
specialists.
Use dust extraction whenever possible.
Provide for good ventilation of the work-
ing place.
It is recommended to wear a P2 filter-
class respirator.
Observe the relevant regulations in your
country for the materials to be worked.
Operation
Starting Operation
f Observe correct mains voltage! The voltage
of the power source must agree with the
voltage specified on the nameplate of the
machine. Power tools marked with 230 V
can also be operated with 220 V.
When operating the machine with power from
mobile generators that do not have sufficient re-
serve capacity or are not equipped with suitable
voltage control with starting current amplifica-
tion, loss of performance or untypical behavior
can occur upon switching on.
Please observe the suitability of the power gen-
erator being used, particularly with regard to
the mains voltage and frequency.
Switching On and Off
To start the power tool, push the On/Off switch
2 forwards.
To lock the On/Off switch 2, press the On/Off
switch 2 down at the front until it latches.
To switch off the power tool, release the On/Off
switch 2 or, if it is locked, briefly push down the
back of the On/Off switch 2 and then release it.
f Check grinding tools before using. The
grinding tool must be mounted properly
and be able to move freely. Carry out a test
run for at least one minute with no load. Do
not use damaged, out-of-centre or vibrating
grinding tools. Damaged grinding tools can
burst and cause injuries.
Reduced starting current
(GWS 850 C/GWS 850 CE)
The electronic reduced starting current limits
the power consumption when switching the tool
on and enables operation from a 13 ampere
fuse.
Constant Electronic Control
(GWS 850 C/GWS 850 CE)
Constant electronic control holds the speed
constant at no-load and under load, and ensures
uniform working performance.
OBJ_BUCH-161-005.book Page 31 Friday, March 12, 2010 9:17 AM