Technical data

adjust the values of the COM interfaces in the BIOS. Alternatively, the IRQ can
also be adjusted via the configuration software of the serial device.
BIOS setting since Q1/2007 BIOS setting until Q1/2007
Menu: I/O Device Configuration Menu: Integrated Peripherals
Serial port C (COM
3):
[Enabled]
Onboard Serial Port
3:
[3E8/IRQ11]
Base I/O address: [3E8]
Interrupt: [IRQ 10]
Serial port D (COM
4):
[Enabled]
Onboard Serial Port
4:
[2E8/IRQ10]
Base I/O address: [2E8]
Interrupt: [IRQ 11]
Fig.7-6: BIOS settings of the COM interfaces
For any questions, please contact your service/sales person or the help desk
+49 (0) 9352 / 40 50 60, see also chapter 12 "Service and Support" on page
77.
7.2.5 Parallel Interface XLPT1
XLPT1 – Parallel interface for print‐
er, scanner, etc.
D-Sub female connector, 25-pin
Type: SPP (ex works), EPP, ECP
Cable length: 3 m max.
Cable type:
Shielded, cross-section min. 0.14 mm
2
Interrupt (IRQ): 7
I/O address: 378H
Fig.7-7: Parallel interface - XLPT1
Bosch Rexroth AG DOK-SUPPL*-VPB*40.1***-PR02-EN-P
Rexroth IndraControl VPB 40.1 Control Cabinet PC
34/81
Connections