Installation instructions
Table Of Contents
- Built-in oven
- Table of ContentsInstallation instructions
- 9 Safety DefinitionsSafety Definitions
- IMPORTANT SAFETY INSTRUCTIONS
- Appliance Handling Safety
- Safety Codes and Standards
- Electric Safety
- Related Equipment Safety
- Proposition 65 Warning:
- Transport
- Parts Included
- Power Requirements
- Preparing the units
- Cabinet Dimensions
- Mount to cabinet
- Check the Installation
- Data Plate
- Service
- Parts and Accessories
- Table des matièresNotice de montage
- 9 Définitions de sécuritéDéfinitions de sécurité
- IMPORTANTES CONSIGNES DE SÉCURITÉ
- Sécurité de manutention des appareils
- Codes et normes de sécurité
- Sécurité électrique
- Sécurité apparentée concernant l´équipement
- Avertissement issu de la proposition 65 :
- Transport
- Pièces comprises
- Exigences électriques
- Préparation du meuble
- Dimensions de la découpe des armoires
- Installation sur un caisson
- Vérification de l'installation
- Plaque signalétique
- Service
- Pièces et accessoires
- ÍndiceInstrucciones de instalación
- 9 Definiciones de seguridadDefiniciones de seguridad
- INSTRUCCIONES DE SEGURIDAD IMPORTANTES
- Seguridad de manejo del electrodoméstico
- Códigos y normas de seguridad
- Seguridad eléctrica
- Seguridad de los equipos relacionados
- Advertencia en virtud de la Proposición 65:
- Transporte
- Piezas incluidas
- Requisitos de electricidad
- Preparación de los muebles
- Dimensiones del hueco para el gabinete
- Unidad empotrada en gabinete
- Pruebe la instalación
- Placa de características
- Servicio técnico
- Piezas y accesorios
7
Install Appliance
Electrical Installation
The ovens is dual rated, designed to be connected to
either 208/240V AC, 60 Hz, 4 wire, single-phase power
supply.
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
NOTICE: Local Codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the oven to the white neutral
electrical supply wire.
9 CAUTION
▯ The appliance must be disconnected from the
power supply during all installation work.
▯ The appliance must only be connected with the
power cable provided.
▯ Protection against contact must be ensured by
the installation.
Electrical Connection
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also
acceptable.
Four-wire Connection
Ungrounded Neutral
▯ Connect the red oven wire to the red electrical supply
wire (hot wire).
▯ Connect the black oven wire to the black electrical
supply wire (hot wire).
▯ Connect the green ground oven wire to the bare or
green ground electrical supply wire.
Three-wire Connection
Grounded Neutral
▯ Connect red wire from oven to red wire in junction box.
▯ Connect black wire from oven to black wire in junction
box.
▯ Connect green ground wire from oven to white, green
or bare neutral wire in junction box.
The conduit cable, where connected at the oven, swivels.
Rotate conduit cable upward (or downward) and direct
through hole prepared in cabinet to attach to junction
box.
To maintain serviceability, the flex conduit must not be
shortened and should be routed to permit temporary
removal of the oven.
*
Flush installation requires a
3
/
16
" (5 mm) high x
22
1
/
16
" (560 mm) wide x 22
7
/
8
" (581 mm) deep base-
plate underneath the unit body.
Model Dedicated
circuit
required
Watts @
240V
Watts @
208V
HBE5452UC 20 AMP 4000 3000
SRZHUVXSSO\
MXQFWLRQER[
UHGZLUHV
JUHHQRUEDUH
JUHHQZLUH
8/OLVWHG
FDEOHIURP
ZKLWHZLUH
EODFNZLUHV
ZLUH
FRQQHFWRU
RYHQ
SRZHUVXSSO\
MXQFWLRQER[
UHGZLUHV
ZKLWHEDUHRU
JUHHQZLUH
JUHHQZLUH
FDEOHIURP
8/OLVWHG
EODFNZLUHV
RYHQ
FRQQHFWRU