ELECTRICAL CONNECTIONS
This appliances is manufactured with a green
GROUND wire connected to the oven chassis.
After making sure that the power has been turned
off connect the flexible conduit from the oven to
the junction box using a U.L. listed conduit con-
nector. Figures A and B and the instructions pro-
vided below present the most common way of
connecting the ovens. Your local codes and ordi-
nances, of course, take precedence to these in-
structions. Complete electrical connections ac-
cording to local codes and ordinances.
3-WIRE BRANCH CIRCUIT
Refer to Figure A, where local codes allow the
connection of GROUND wire from the oven to
the branch circuit NEUTRAL wire (grey or white
colored wire):
If local codes permit, connect the green
GROUND wire from the oven and the white
wire from the oven to the branch circuit NEU-
TRAL wire (grey or white colored wire).
Connect the red and black leads from the oven
to the corresponding leads in the junction box.
Junction box _ CaNe from
_er Grounded Neutram
suppUy
Whitewires Red wires. _ __
Bare o_ _ "BHack wires
CaMe _ U.L.-Iisted conduit connector
from oven
Figure A.
4-WIRE BRANCH CIRCUIT
Refer to Figure B:
Connect the green GROUND wire from the
oven to the GROUND wire in the junction box
(bare or green colored wire).
Connect the red and black leads from the oven
to the corresponding leads in the junction box.
Connect the white wire from the oven to the
NEUTRAL (grey or white) wire in the junction
box.
Junction box CaNe from
_-_. power suppHy
White wires
Ungrounded Neutram
BHack wires
Bare or green wures CabHe _.
from oven _ U.LMisted conduit connector
Figure B.
10