Technical data
Commissioning | 15
8 716 473 216 (2014/09)Gaz 6000 W
6.3.2 Replacing the power cable
Use only original power cable.
The control unit must be opened to connect the power cable.
▶ Disconnect the ignition cable.
▶ Remove cover.
▶ Remove old cable.
▶ Plug new cable connector on the conductor board.
▶ Plug strain relief to the case.
▶ Mount cover.
▶ Connect ignation cable.
Fig. 17
7 Commissioning
Fig. 18
[1] Drain hose
[2] Heating return valve (accessory)
[3] Cold water valve (accessory)
[4] Gas valve (closed) (accessory)
[5] Heating flow valve (accessory)
[6] Automatic air vent valve
[7] Standby key
[8] Display
[9] “Back” key (= exit service function/submenu without saving)
[10] + key
[11] OK button (= confirm selection, save value)
[12] – key (mode)
[13] Pressure gauge
[14] System top-up fixture
[15] Test point
[16] Cold water supply
6 720 806 640-17.1O