Installation guide
5C)
Four
Wire
Flexible
Conduit
Con-
nection
English
10
Note:
DO
NOT
piug
in
range
at
this
time.
1.
2.
3.
Disconnect
electrical
power
at
the
breaker
box.
Remove
the
terminal
block
cover
to
expose
the
terminal
block.
Remove
the top
nut,
star
washer,
and
round
washer
from
each
post.
Note:
DO
NOT
remove
last
round
washer,
last
nut
or
internal
wire
leads.
4.
Remove
screw
from
bottom
end
of
ground
strap.
5.
Remove
ground
strap
from
center
post.
Discard.
6.
Attach
one
terminal
lug
(packaged
with
this
manual)
through
hole
below
termi-
nal
block
with
ground
screw.
7.
Place one
terminal
lug
(packaged
with
this
manual)
on
each
post.
Replace
the
star
washer
and
round
washer
and
secure
with
20
inch
pounds
of
torque.
8.
Strip 3/8
(9.53
mm)
inches
of
insulation
from
the
end
of
the
wire.
|e
ad
-—
3/8
“
Figure
12:
Wire
Stripping
9.
Insert
the
insulated
grounding
wire
into
the
lug
below
the
terminal
block.
10.
Insert
stripped
end
of
white
wire
into
the
center
lug.
Secure
the
clamping-
screw.
7
FI
clamping
screw
WIPE
mene
Figure
13:
Attaching
Wire
to
Lug
11.
Insert
stripped
end
of
red
wire
into
the
left
lug.
Secure
clamping
screw.
12.
Insert
black
wire
into
the
right
lug.
Secure
clamping
screw.
13.
Tighten
each
clamping
screw
with
the
appropriate
torque
(see
table).
Table
2:
Appropriate
Torque
Levels
for
Aluminum
or
Copper
Wire
Gauge
Torque
(in./Ibs.)
Torque
(Nm)
6
35
3.95
8
25
2.82