Installation guide
14.
Properly
secure
flexible
conduit
at
knockout
on
angle
and
at
supply
side
junc-
tion
box.
The
wiring
is
now
complete.
black
wire
red
wire
white
wire
green
ground
wire
Figure
14:
Completed
Four Wire
Flexible
Conduit
Connection
Note:
DO
NOT
piug
in
range
at
this
time.
5D)
Three
Wire
Flexible
Conduit
Con-
The
Four
Wire
Connection
is
preferred,
but
where
local
codes
and
ordinances
nection
permit
grounding
through
neutral
and/or
conversion
to
four
wire
is
impractical,
unit
may
be
connected
to
the
power
supply
via
a
three
wire
connection.
1.
Disconnect
electrical
power
at
the
breaker
box.
2.
Remove
the
terminal
block
cover
to
expose
the
terminal
block.
Figure
15:
Terminal
Block
3.
Remove
the top
nut,
star
washer,
and
round
washer
from
each
post.
Note:
DO
NOT
remove
last
round
washer,
last
nut
or
internal
wire
leads.
4.
Place one
terminal
lug
(packaged
with
this
manual)
on
each
post.
Replace
the
star
washer
and
round
washer
and
secure
with
20
inch
pounds
of
torque.
5.
Strip 3/8
(9.53
mm)
inches
of
insulation
from
the
end
of
each
wire.
HI
3/8
“
Figure
16:
Wire
Stripping
English
11