IS76 Beacon with Ferrite Antenna Installation Manual V2 | F.01U.278.518 | 2013.
Document # F.01U.278.518 V2 IS76 Beacon with Ferrite Antenna: Installation Manual Edition: October 2013 Author: TeleAlarm © TeleAlarm SA 2013 All rights reserved. TeleAlarm SA reserves the right to make changes to information contained in this document at any time without prior notice. Great care has been given to the contents of this document.
Content Locator Function .................................................................................................................................................. 4 IS76 Beacon with Ferrite Antenna ................................................................................................................ 5 IS76 Ferrite Antenna...................................................................................................................................... 5 IS76 Ferrite Beacon Controller ..
Locator Function The Resident Alert System can be set to handle a locator function. For this purpose, beacon modules and antennas of type IS75 or IS76 need to be installed on doors or corridors in the building you want to supervise. When passing one of these modules the Wristband Transmitters of type MIYS37L refresh the position information that is stored into them.
IS76 Beacon with Ferrite Antenna The IS76 Beacon system consists of two elements: The IS76 Ferrite Antenna The IS76 Ferrite Beacon Controller IS76 Ferrite Antenna The IS76 Ferrite antenna has to be mounted on the place that has to be identified with a location beacon code. The antenna is well suited to be mounted in a vertical position on (or next to) a door frame. In some circumstances it may also be mounted horizontally. The IS76 Ferrite Antenna can be placed outdoors as well as indoors.
Features of the IS76 Beacon System Ferrite antenna offers a better defined capture range that is less dependent on the surrounding building material The antenna may be installed in or outdoors Up to 230 user selectable position (location) codes (001 to 230) Up to 24 user selectable "Wandering" codes (231 to 254) Supervision of the beacon functionality IS76 Ferrite Antenna The antenna is best fitted to be mounted vertically on a door's frame.
IS76 Beacon Controller The IS76 Beacon Controller can be fixed with two to five screws on the wall. Two holes at 2.36 in (60 mm) interval are provided for direct mounting on connection boxes. The three upper holes are used for positioning the device and cannot be reached from the Connection Compartment. Two of the lower holes can be reached from outside and thus used for fixing the device. 3.4 in (80 mm) 2.2 in (53.8 mm) 0.51 in (13.1 mm) 0.15 in (3.7 mm) 0.63 in (16 mm) 0.26 in (6.6 mm) n .
Connection Compartment All of the wiring and configuration functions such as: • Connection of the IS76 Ferrite Antenna(s) • Connection of the wired supervision output • Setting of the Location identification code can be carried out in the connection compartment. It is reached by taking off the lower part of the housing (see). This can be done even if the device is fixed on the wall.
Configuration and Wiring *Antenna B is optional It is used to extend the capture range on large (double) doors B* A + 128 + 64 + 32 + 16 + 8 + 4 + 2 + 1 Position number: ON *Polarity of the antenna and the wiring has to be respected when two antennas are used for the same beacon location Supervision of Beacon B: Enabled Disabled Supervision O utput Supervision of Beacon A: Power Supply 24 VDC Example above: 1x128 + 1x64 + 1x32 + 1x16 + 1x8 + 0x4 + 0x2 + 0x1 = 248 Blue* Ferrite Beacon Antenna B*
Ferrite Beacon Antenna Housing Plastic case ASA for wall mounting L x H x P 24 x 1.2 x 1.2 in (600 x 30 x 30 mm) Weight 24.7 oz (700 g) Operation Range1 Connecting cable 6.6 ft (2 m) "twisted pair" may be extended up to 32 ft (10 m) Antenna 1 typ. 11.8 ft (3.6 m) typ. 8.5 ft (2.6 m) When used in conjunction with MIYS37L Wristband Transmitters of REV B and higher. Ferrite Beacon Controller Housing Plastic case ASA For wall mounting (H x W x D) Weight 5.2 x 3.2 x 1.
FCC Statement for Class B digital device Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Robert Bosch Healthcare Systems, Inc. 2400 Geng Road, Suite 200 Palo Alto, CA 94303 U.S.A. Phone: 650-690-9100 Toll Free: 1-888-947-8957 Fax: 650-798-3770 www.bosch-telehealth.com __________________________________________________________________________________________________________________ Installation Manual V2 | F.01U.278.518 | 2013.